• Title/Summary/Keyword: power station

Search Result 1,328, Processing Time 0.026 seconds

Analysis of Adjacent Channel Interference for WCDMA ATC Service Frequency Allocation Operating in MSS Band (MSS 대역 WCDMA ATC 서비스 주파수 할당을 위한 인접 채널 간섭 분석)

  • Kang, Young-Heung;Jeong, Nam-Ho;Oh, Dae-Sub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1288-1296
    • /
    • 2012
  • A candidate hybrid satellite and terrestrial network architecture, MSS/ATC(Mobile Satellite Service/Ancillary Terrestrial Component), is proposed for utilizing efficiently the exist MSS bands. Studies on the adjacent channel interference from the existing terrestrial mobile services and MSS/ATC itself are important to allocate a new ATC service frequency in MSS band. In this paper, we have analyzed the minimum permission power of terrestrial base station and the capacity loss with parameters of ACIR, number of MS(mobile Station) and MES(Mobile Earth Station) in uplink, and also, the capacity performance based on 1 beam and 1 cell assumption for MSS/ATC in downlink. The ACIR requirements are estimated in two MSS/ATC frequency allocation scenarios for 5 MHz and 10 MHz guard band to share spectrum with adjacent systems, and according to these ACIR requirements the service coverage and the receiver filter for ATC system should be designed in near future.

Analysis on Characteristics for Sharing Co-channel between Communication Systems (통신 시스템간 채널 공유를 위한 특성 분석)

  • Cho, Ju-Phil;Cho, Sang-In;Kang, Kyu-Min;Hong, Heon-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.251-256
    • /
    • 2011
  • In this paper, we analyze the distance between two systems, WiBro and WLAN, compared to standard interference probability for channel co-use in order to be used as a criteria in realization. Co-channel and adjacent channel interference probability and its effect of (WiBro) into Wireless LAN (WLAN) in TV White Spaces (TVWS) is evaluated through Spectrum Engineering Advanced Monte Carlo Analysis Tool(SEAMCAT) based on the Monte-Carlo simulation method. As a result, in the case of co-channel interference, the minimum distance between WiBro Mobile Station(MS) and WLAN User Equipment (UE) should be 210 m to allow the maximum transmitter power of WiBro UE of 25 dBm. The transmit power of WiBro BS have to be reduced to -4.96 dBm.

Prediction of radioactivity releases for a Long-Term Station Blackout event in the VVER-1200 nuclear reactor of Bangladesh

  • Shafiqul Islam Faisal ;Md Shafiqul Islam;Md Abdul Malek Soner
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.696-706
    • /
    • 2023
  • Consequences of an anticipated Beyond Design Basis Accident (BDBA) Long-Term Station Blackout (LTSBO) event with complete loss of grid power in the VVER-1200 reactor of Rooppur Nuclear Power Plant (NPP) of Unit-1 are assessed using the RASCAL 4.3 code. This study estimated the released radionuclides, received public radiological dose, and ground surface concentration considering 3 accident scenarios of International Nuclear and Radiological Event Scale (INES) level 7 and two meteorological conditions. Atmospheric transport, dispersion, and deposition processes of released radionuclides are simulated using a straight-line trajectory Gaussian plume model for short distances and a Gaussian puff model for long distances. Total Effective Dose Equivalent (TEDE) to the public within 40 km and radionuclides contribution for three-dose pathways of inhalation, cloudshine, and groundshine owing to airborne releases are evaluated considering with and without passive safety Emergency Core Cooling System (ECCS) in dry (winter) and wet (monsoon) seasons. Source term and their release rates are varied with the functional duration of passive safety ECCS. In three accident scenarios, the TEDE of 10 mSv and above are confined to 8 km and 2 km for the wet and dry seasons, respectively in the downwind direction. The groundshine dose is the most dominating in the wet season while the inhalation dose is in the dry season. Total received doses and surface concentration in the wet season near the plant are higher than those in the dry season due to the deposition effect of rain on the radioactive substances.

Distributed Uplink Resource Allocation in Multi-Cell Wireless Data Networks

  • Ko, Soo-Min;Kwon, Ho-Joong;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.12 no.5
    • /
    • pp.449-458
    • /
    • 2010
  • In this paper, we present a distributed resource allocation algorithm for multi-cell uplink systems that increases the weighted sum of the average data rates over the entire network under the average transmit power constraint of each mobile station. For the distributed operation, we arrange each base station (BS) to allocate the resource such that its own utility gets maximized in a noncooperative way. We define the utility such that it incorporates both the weighted sum of the average rates in each cell and the induced interference to other cells, which helps to instigate implicit cooperation among the cells. Since the data rates of different cells are coupled through inter-cell interferences, the resource allocation taken by each BS evolves over iterations. We establish that the resource allocation converges to a unique fixed point under reasonable assumptions. We demonstrate through computer simulations that the proposed algorithm can improve the weighted sum of the average rates substantially without requiring any coordination among the base stations.

Development of Coating Robot Automation System Based on OLP for Radiators in PPS (페키지형 발전시스템용 라디에이터의 OLP 기반 코팅로봇 자동화시스템 개발)

  • Kim, Seon-Jin;Lee, Jong-Hwan;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.585-591
    • /
    • 2013
  • A robot automation system for coating uniformly a big radiator used in PPS(Packaged Power Station), which consists of 6-axis robot with spray gun, travelling vehicle, supply device of coating paint and thinner with pressured air, HMI controller and robot path OLP(Off-Line Programming), was developed. Experimental results on an optimum operation condition show that a coating thickness is $43{\mu}m$, which is satisfied to a design reference of $25-100{\mu}m$. A productivity of the developed coating robot automation system based on OLP is about 12.6 times of that of manual operation.

Physical Layer Secrecy Performance of RF-EH Networks with Multiple Eavesdroppers

  • Truong, Tien-Vu;Vo, Nhan-Van;Ha, Dac-Binh;Tran, Duc-Dung
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.3
    • /
    • pp.171-176
    • /
    • 2016
  • In this study, we investigate the physical layer secrecy performance of RF energy harvesting (EH) networks over Rayleigh fading channels. The RF-EH system considered here consists of one power transfer station, one source, one destination, and multiple passive eavesdroppers. The source harvests energy from the power transfer station and transmits the information to the destination by using a time switching-based relaying protocol. The eavesdroppers try to extract the transmitted information without an active attack. By using the statistical characteristics of the signal-to-noise ratio (SNR), the exact closed-form expressions of the existence probability of the secrecy capacity and the secrecy outage probability are derived. Further, we analyze the secrecy performance of the system with respect to various system parameters, such as the location of the system elements and the number of eavesdroppers. Finally, the equivalent Monte Carlo simulation results are provided to confirm the correctness of our calculations.

Radio Resource Management Algorithm for Uplink Coordinated Cooperative Spatial Multiplexing (셀 간 협동 CSM에서 상향 링크 용량 개선을 위한 자원 할당 알고리즘)

  • Mun, Cheol;Jo, Han-Shin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1311-1317
    • /
    • 2010
  • In this paper, for a uplink space division multiple access system named cooperative spatial multiplexing(CSM), radio resource management(RRM) algorithms are proposed based on sharing uplink channel information among a serving base station(BS) and interfering BSs in a uplink coordinated wireless communication system. A constrained maximum transmit power algorithm is proposed for mobile station(MS) to limit uplink inter-cell interference(ICI). And joint scheduling algorithm among coordinated BSs is proposed to enhance uplink capacity through ICI mitigation by using channel information from interfering BSs. It is shown that the proposed RRM algorithm provides a considerable uplink capacity enhancement by effective ICI mitigation only with moderate complexity.

Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring (SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발)

  • Ha, B.N.;Lee, S.W.;Shin, C.H.;Seo, I.Y.;Jang, Mun-Jong;Park, M.H.;Yun, G.G.;Song, I.K.;Lee, B.S.;Lee, J.C.;NamKoong, W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

Analysis on the Induction Effects by Separation Distance between the Power Feeding Station and the Telecommunication Cables (고속전철 급전소와의 이격거리에 따른 전력 유도 영향 분석)

  • Choi, Mun-hwan;Lee, Snag-mu;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.573-576
    • /
    • 2012
  • We have analyzed the induction effects by separation distance between the power feeding station and the telecommunication cables. To do this we measured the induced voltage in 11 sections(10km) between Jangseong and Imgok at Jeon-nam province using telecommunication cable installed nearby KTX's feeder line. Sub-section has about 1km length of telecommunication cable. And we used normalization method in installed length of telecommunication cables and mutual inductance to analysis the induction effects more rationally.

  • PDF

Monitoring of hot waste water spread from coastal power station by the Landsat TM images (확산의 모니터링)

  • Cheoi, Seung-Pil;Yang, In-Tae;Lee, Kee-Boo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.1 s.11
    • /
    • pp.105-116
    • /
    • 1998
  • The spreading of hot waste water discharged from the coastal power station is a new problem to marin e circumstances and the fishery. Because the survey of hot waste water discharges should be performed is multaneously across wide areas, it is very difficult. Some sensors of the Landsat can draw the spread and distribution of water temperature from wavelength range of thermal infrared. The present study applied the GIS after stretching DN for the purpose of drawing a more accurate distribution of water temperature. Accordingly, the pattern of water temperature distribution could be expressed more precisely for a broad area, and the spread and distribution of hot waste water could be analyzed economically.

  • PDF