• 제목/요약/키워드: power station

검색결과 1,325건 처리시간 0.023초

급속충전기용 파워 모듈을 위한 단일단 AC-DC 컨버터 (A Single-Stage AC-DC Power Module Converter for Fast-Charger)

  • 레덧탕;최세완
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.384-390
    • /
    • 2022
  • In this study, a single-stage, four-phase, interleaved, totem-pole AC-DC converter is proposed for a super-fast charger station that requires high power, a wide voltage range, and bidirectional operation capabilities and adopts various types of electric transport vehicles. The proposed topology is based on current-fed push-pull dual active bridge converter combined with the totem-pole operation. Owing to the four-phase interleaving effect, the bridge on the grid side can switch at 0.25, 0.5, and 0.75 to achieve a ripple-free grid current. The input filter can be removed theoretically. Switching methods for the duty of the secondary-side duty cycle are proposed, and they correspond to the primary duty cycle for reducing the circulating power and handling the total harmonic distortion. Therefore, the converter can operate under a wide voltage range. Experimental results from a 7.5 kW prototype are used to validate the proposed concept.

경제성분석 프로그램을 이용한 도심형 마이크로그리드 최적 설계 (Optimal Design of Urban MICROGRID using Economical Analysis Program)

  • 유승덕;임성우;임유석;황성욱;이학주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.69-72
    • /
    • 2022
  • This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.

Positioning of Wireless Base Station using Location-Based RSRP Measurement

  • Cho, Seong Yun;Kang, Chang Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제8권4호
    • /
    • pp.183-192
    • /
    • 2019
  • In fingerprint-based wireless positioning, it is necessary to establish a DB of the unmeasured area. To this end, a method of estimating the position of a base station based on a signal propagation model, and a method of estimating the information of the received signal in the unmeasured area based on the estimated position of the base station have been investigating. The purpose of this paper is to estimate the position of the base station using the measured information and to analyze the performance of the positioning. Vehicles equipped with a GPS receiver and signal measuring equipment travel the service area and acquire location-based Reference Signal Received Power (RSRP) measurements. We propose a method of estimating the position of the base station using the measured information. And the performance of the proposed method is analyzed on a simulation basis. The simulation results confirm that the accuracy of the positioning is affected by the measured area and the Dilution of Precision (DOP), the accuracy of the position information obtained by the GPS receiver, and the errors of the signal included in the RSRP. Based on the results of this paper, we can expect that the position of the base station can be estimated and the DB of the unmeasured area can be constructed based on the estimated position of the base stations and the signal propagation model.

이중화 자동복구 보안기능이 구비된 배전반의 보안성 평가를 위한 테스트베드 구성에 대한 고찰 (An Inquire into Test Bed Compositions in Assessing the Security of a Soft Redundancy Sub-Station System with Auto-Restoration)

  • 최형석;진창기;배기덕
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.99-109
    • /
    • 2012
  • Sub-station, key equipment in electric power infrastructure, are being exposed to increasing risk of hacking. For this, soft redundancy sub-station system needs to be formulated with automatic restoration mechanism. For this it is important to assess the reliability of the applicable range of data that are used in actual system operation, as well as the methods and findings of the tests. At the same time performance of soft redundancy system and total security mechanism, which are aligned for the protection of the sub-station, need to be tested. For testing the above-mentioned, this paper presented a viable formation of a soft redundancy practical VPN system within a panel to protect the latter from hacking or cracking incidences, and conducts a test to check if the considered system actually serves the protection function in the actual operation setting, gathering evidence from the data from the testing of the actual performance of the system as well as of emergency scenario simulation operations. Because tested soft-redundancy & restorative sub-station system is expected to be widely applicable for various cases such as Smart-grid or electricity IT system, where VPN with enhanced level of security is required.

다중 채널을 지원하는 Voice over Sensor Network(VoSN) Base Station 설계 (A Design of Voice Over Sensor Network (VoSN) Base Station with Multi-Channel Support)

  • 이훈재;이재형;강민수;조성호
    • 한국통신학회논문지
    • /
    • 제39C권1호
    • /
    • pp.90-96
    • /
    • 2014
  • 센서 네트워크를 위한 표준인 IEEE802.15.4는 저전력, 저속 데이터 통신이 특징으로 주로 ZigBee 네트워크와 같은 Wireless Personal Area Network (WPAN)를 구성하기 위해 사용하고 있다. 그러나 최근 센서 네트워크 기반의 음성통신과 Session Initiation Protocol (SIP)를 연동하여 장거리 및 대규모 사용자를 지원하기 위한 연구가 활발히 진행되고 있다. 본 논문에서는 센서 네트워크 기반의 음성통신과 SIP를 연동하여 다수 사용자 지원하고 기존 시스템을 하나의 통합 Base Station으로 설계하였다. 또한, 설계한 Base Station의 성능을 평가하기 위하여 사용자수 증가에 따른 Packet 수와 Delay를 측정하였다.

지하철역과 연계된 시설이 역사 내부 상업공간 임대료에 미치는 영향 (Effects of Facilities Linked to the Subway Stations on the Rent of Commercial Spaces Inside the Stations)

  • 조영혜;이명훈
    • 한국콘텐츠학회논문지
    • /
    • 제22권1호
    • /
    • pp.261-273
    • /
    • 2022
  • 본 연구는 역사 내·외부 연계시설이 개별 임대 매장들이 집적된 역사 내부 상업공간의 활성화에 영향을 주는지를 분석하였다. 활성화 판단 요인을 매출을 대체할 수 있는 임대료로 하였다. 판매, 문화, 업무/주거, 공공기관, 교통의 연계시설 변수 외 역사의 입지 요인인 일일 승하차 인원과 역사 내부 상업공간의 가장 많은 업종수를 차지하는 상품 판매업을 독립변수로 선정하였다. 회귀분석 결과, 임대료는 상품 판매업, 연계된 판매, 교통시설 그리고 승하차 인원에 영향이 있다는 것을 증명하였다. 이러한 결과는 역사 내 상업공간 활성화에 구매력을 높일 수 있는 판매 상품 구성과 역사 내부로 유입인구를 증가시킬 수 있는 시설 연계 방향이 필요함이 도출된 것이다. 정책적인 관리 방안으로 활성화가 위축되어 공실 발생률이 높은 역사는 일상생활과 주민 편익을 위한 생활밀착형 생활 SOC 설치를 제언하였다.

CFD에 의한 펌프장 Sump내 유동해석 (Flow Analysis around within Sump in a Pump Station using by the CFD)

  • 노형운;김재수;서상호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.89-94
    • /
    • 2002
  • n general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Uneven flow distribution can also increase or decrease the power consumption with a change in total developed head. To avoid these sump problems pump station designers are considered intake structure dimensions, such as approaching upstream, baffle size, sump width, width of pump cell and so on. From this background, flow characteristics of intake within sump are investigated numerically to obtain the optimal sump design data. The sump model is designed in accordance with HI code.

  • PDF

A Economic Feasibility Analysis of Energy Saving Technology Application to Underground Subway Station

  • Kim, Hyungchul;Shin, Seungkwon;Jung, Hosung;Kim, Jin-o;Cha, Junmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.36-40
    • /
    • 2015
  • In Korea, new total energy-saving solution has planned to build test-bed in underground subway station. Breaking energy is one of the most energy saving method in railway, but it has not be fully used up for economical purpose. This paper demonstrates on energy saving technology application including breaking energy and heating energy to underground subway station. It also offer solution of optimization of power energy flow. Moreover, economic feasibility analysis performed for undergound test bed constuction.

전기철도시스템의 접지 유형에 따른 귀선 전류 비교 (Comparison of Return current by the Earth type in the Electrical railway system)

  • 이길노;김용규;백종현;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.53-55
    • /
    • 2005
  • In electrical railway system, power supplied to electrical locomotive by catenary is returned to sub-station on track. The current returned to sub-station on track is return current, which is an essential factor for the safety of the wayside electrical equipment and maintenance staff. Therefore, earth system acts an important role to protect wayside electrical equipment and maintenance staff against return current. In general, individual earth system protects partially the electrical railway system, but common earth system does the whole electrical railway system and minimizes the flow of return current. In this paper, we are compared the effect of return current according to earth type by actual measurement in existing electrical railway system. The measurement was conducted at Shinchungju sub~station in high speed trains, and Guro sub-station, which is electrified section in classical line.

  • PDF