• 제목/요약/키워드: power river

검색결과 286건 처리시간 0.023초

Flood Risk for Power Plant using the Hydraulic Model and Adaptation Strategy

  • Nguyen, Thanh Tuu;Kim, Seungdo;Van, Pham Dang Tri;Lim, Jeejae;Yoo, Beomsik;Kim, Hyeonkyeong
    • 한국기후변화학회지
    • /
    • 제8권4호
    • /
    • pp.287-295
    • /
    • 2017
  • This paper provides a mathematical approach for estimating flood risks due to the effects of climate change by developing a one dimensional (1D) hydraulic model for the mountainous river reaches located close to the Yeongwol thermal power plant. Input data for the model, including topographical data and river discharges measured every 10 minutes from July $1^{st}$ to September $30^{th}$, 2013, were imported to a 1D hydraulic model. Climate change scenarios were estimated by referencing the climate change adaptation strategies of the government and historical information about the extreme flood event in 2006. The down stream boundary was determined as the friction slope, which is 0.001. The roughness coefficient of the main channels was determined to be 0.036. The results show the effectiveness of the riverbed widening strategy through the six flooding scenarios to reduce flood depth and flow velocity that impact on the power plant. In addition, the impact of upper Namhan River flow is more significant than Dong River.

NTrend 1.0에 의한 낙동강 수질 장기변동 추세분석 (Long-Term Water Quality Trend Analysis with NTrend 1.0 Program in Nakdong River)

  • 유재정;신석호;윤영삼;송재기
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.895-902
    • /
    • 2010
  • The effect of seasonality on water quality variation is very significant. Generally, it reduce the power of the trend extraction. A parametric time-series model was used for detecting trends in historic constituent concentration data. The effect of seasonality is able to remove from time series decomposition technique. According to such statistic methode, long-term water quality trend analysis system (NTrend 1.0) was developed by Nakdong River Water Environmental Research Center. The trend analysis of BOD variation was conducted with NTrend 1.0 at Goreong and Moolkum site in Nakdong river to show the effect of water quality management action plan. Power test of trend extraction was tried each case of 'deseasonalized and deannulized' data and 'deseasonalized' data. Analysis period was from 1989 to 2006, and it's period was divided again three times, 1989~1993, 1994~1999 and 2000~2006 according to action plan period. The BOD trend was downward in Goreong site during three times and it's trend slope was very steep, and upward in Moolkum during 1989~1993, but it was turned downward during 1994~1999 and 2000~2006. It was revealed that it's very effective to reduce the concentration of BOD by water quality management action plan in that watershed. The result of power test was shown that it is high for trend extraction power in case of 'deseasonalized' data.

Dynamic Programming에 의한 최적제어 ("Optimal Control of - Hydraulic Sources of Han River by Multiple Dynamic Programwing")

  • 양흥석;박영문
    • 전기의세계
    • /
    • 제23권3호
    • /
    • pp.53-59
    • /
    • 1974
  • The purpose of this paper is to use hydraulic sources optimally on the hydro-thermal power coordination in power system of Korea by means of Multiple Dynamic Programming. Four principal hydraulic power plans of Korea; Whachon, Chunchon, Uiam and Chong-pyong which are located on Han river side are treated in this research. For the illustrative purpose, a case study was made on the year round monthy optimal water control under the given load distribution and constraints.

  • PDF

친환경 소하천의 수리적 안정성 분석에 관한 연구 (A Study on Hydraulic Stable Analysis of The Natural Small River)

  • 김태경;이경훈;선병진;최천호
    • 환경영향평가
    • /
    • 제16권3호
    • /
    • pp.187-194
    • /
    • 2007
  • It started road constructions around river in 1990s. These maintenances concentrate on city river. Because river lives no living things and men don't come near there. But in spite of these river environment go to rack, river maintenances still keep on using preexistence method since 1990s. Only a part of city river environment maintenances consider environmental ability of passive river, river maintenance of a purpose of flood control still don't consider in the concrete. Because propulsion device that consider environment ability of passive river and possible application techniques don't complete. In accordance, A natural river maintenance needs absolutly a series of river projects. Because a natural river maintenance prevents a damage of environment ability. This study is to assume the flood really happened and to carry out the flood damage simulation needed in overflow simulation about the inundated zone. Also, This study examine unstable part about the hydraulic characteristic as velocities, stream power, shear, hydraulic depth, flow area in basin. And this study applied the HEC-RAS(river analysis system) model to predict flood overflow in youngsan river basin. Project flood is used the return period 100 year and inputed data that was calculated in intensity figures of illumination.

통합운영체계의 DSA 적용 연구 (The Study on DSA of Intergrated Operating System)

  • 조남빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2322-2324
    • /
    • 2002
  • Korea Water Resources Corporation (KOWACO) operates nine hydroelectric power stations on the Han River, Nakdong River, Geum River & Seomjin River Areas. KOWACO will take the lead in improving the efficiency of water resources supply in this parer, KOWACO Generation Intergrated Operating System(GIOS) project will improve the generating plant, hydraulic structures, switchgear, and station controls, alarms and services for unmanned remote controlled operation by modern intergraed SCADA system. Mordern SCADA is used to cover all computer systems designed to perform the following main functions: - to collect data from industrial plant devices. - to process and perform calculations on the collected. - to present collected and derived data on displays on. - to accept commands entered by human operators and act on them such as sending control commands to plant devices.

  • PDF

PREDICTIONS OF CRITICAL HEAT FLUX USING THE ASSERT-PV SUBCHANNEL CODE FOR A CANFLEX VARIANT BUNDLE

  • Onder, Ebru Nihan;Leung, Laurence Kim-Hung;Rao, Yanfei
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.969-978
    • /
    • 2009
  • The ASSERT-PV subchannel code developed by AECL has been applied as a design-assist tool to the advanced $CANDU^{(R)1}$ reactor fuel bundle. Based primarily on the $CANFLEX^{(R)2}$ fuel bundle, several geometry changes (such as element sizes and pitch-circle diameters of various element rings) were examined to optimize the dryout power and pressure-drop performances of the new fuel bundle. An experiment was performed to obtain dryout power measurements for verification of the ASSERT-PV code predictions. It was carried out using an electrically heated, Refrigerant-134a cooled, fuel bundle string simulator. The axial power profile of the simulator was uniform, while the radial power profile of the element rings was varied simulating profiles in bundles with various fuel compositions and burn-ups. Dryout power measurements are predicted closely using the ASSERT-PV code, particularly at low flows and low pressures, but are overpredicted at high flows and high pressures. The majority of data shows that dryout powers are underpredicted at low inlet-fluid temperatures but overpredicted at high inlet-fluid temperatures.

The Analysis of Hydropower Development and the Mekong Power Grid on Regional Cooperation : Focus on the Greater Mekong Subregion Program

  • Nayeon Shin;Seungho Lee
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.245-245
    • /
    • 2023
  • This paper examines the extent to which the Mekong River Basin countries have achieved socioeconomic benefits based on regional cooperation through the Greater Mekong Subregion (GMS) Program, focusing on hydropower development and the Mekong Power Grid. This study pays attention to the time period from 2012 to 2022. The benefit sharing approach is employed to evaluate the extent to which hydropower development and the Mekong Power Grid have contributed to the regional energy trade in the GMS program. The GMS program was launched by the Asian Development Bank (ADB) in 1992, and the Chinese provinces of Yunnan and Guangxi, Myanmar, Lao PDR, Thailand, Cambodia, and Vietnam have taken an active part in the program. The goals of the GMS program are to achieve poverty alleviation, economic development, and regional cooperation in various sectors, including energy, tourism, and transportation. The GMS Economic Cooperation Program Strategic Framework 2030 (GMS-2030), in 2021, provides a new framework for prosperous and sustainable development in the river basin. In the energy sector, the GMS program has been instrumental in facilitating hydropower development and creating the Mekong Power Grid with the Regional Grid Code (RGC), contributing to economic benefits and promoting regional trade of hydroelectricity. It is argued that the GMS program has enhanced regional cooperation between the riparian countries. Despite such achievements, the GMS program has faced challenges, including the gap of economic development between the riparian countries, socioeconomic and environmental concerns regarding hydropower development between the Upper and Lower Mekong countries, and geopolitical tensions from the US-China rivalry. These challenges should adequately be addressed within the program, which can guarantee the sustainability of the program for the river basin.

  • PDF

The presence of carcinogenic radon in the Padma River water, adjacent to the Rooppur Nuclear Power Plant

  • M.M. Mahfuz Siraz;M.S. Alam;Jubair A.M.;S.C. Das;J. Ferdous;Z. Hossain;S. Das;Mayeen Uddin Khandaker;D.A. Bradley;Shinji Tokonami;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.3046-3053
    • /
    • 2023
  • Radon is a naturally occurring carcinogenic agent, poses a serious health hazard when inhaled or ingested in significant amounts. The water of the Padma river will be used as a tertiary coolant for the soon-to-be-commissioned 'Rooppur Nuclear Power Plant'. Hence, it is important to assess the radiological status of the river prior to the commission of this power plant. Therefore, for the first time, 25 samples of water were collected from various locations of the Padma River and analyzed for radon concentration using the RAD H2O (DURRIDGE) radon monitoring device. The radon concentrations were found in the range from 0.077 ± 0.036 to 0.494 ± 0.211 Bq/L with a mean of 0.250 ± 0.093 Bq/L. All the concentrations were found to be below the recommended limits of WHO (100 Bq/L) and USEPA (11.1 Bq/L). The mean annual effective dose due to the radon exposure via inhalation and ingestion pathways were 0.638 µSv/y and 0.629 µSv/y, respectively, which were all well below the annual effective dose recommended by WHO (0.1 mSv/y). Since Bangladesh lacks a national safety limit of radon in water, this pioneering study provides baseline data on radon levels for the environment around Rooppur Nuclear Power Plant.

섬진강 유출수의 3차원 거동 특성 (Three-dimensional Mixing Behaviour Characteristics of Seomjin River Discharges)

  • 김종규;김명원;강태순;윤은찬
    • 한국해양공학회지
    • /
    • 제20권4호
    • /
    • pp.50-57
    • /
    • 2006
  • The effect of discharges from the Seomjin River on the dispersion of thermal effluent from the Hadong Power Plant, located along the south coast of Korea, was investigatedusing intensive field observation and three-dimensinal Princeton Ocean Model simulations. A POM and observed CTD data was used to predict the mixing behaviour of the Summer freshet, during the July 2005 intensive observing period. The dispersal of the river discharge anomaly, associated with the Seomjin River plume, was seen to be highly responsive to tidal currents and river flows during the spring tide.