• Title/Summary/Keyword: power regulation

Search Result 1,331, Processing Time 0.024 seconds

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

Development and Demonstration of Trial-run Automation System of Energy Storage System for Frequency Regulation (주파수조정용 에너지저장장치 시운전 자동화 시스템의 개발과 실증)

  • Lim, Geon-Pyo;Choi, Yo-Han;Lee, Seung-Min;Park, Chan-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.110-116
    • /
    • 2017
  • System to automate the trial-run of energy storage system for frequency regulation was developed and demonstrated. Basic strategy was developed on the basis of trial-run procedure and verified in the computer simulation tool. The algorithm was developed and coded for 4MW trial-run automation system. 4MW trial-run automation system was connected to 4MW energy storage system for frequency regulation in Jocheon substation of Jeju city and demonstrated. 24MW trial-run automation system was developed on the basis of 4MW trial-run automation system and verified by operation system for 24MW energy storage system for frequency regulation. The operation system has own simulation model of energy storage system and power system. The verification was performed to improve the system in the view of user. 24MW trial-run automation system was demonstrated in 32MW Ul-san and 36MW Non-gong energy storage system. All tests of trial-run was done by manual and first they ware taken 1 week with no trial-run automation system. The manual trial-run tests were taken by maximum three times. Trial-run test by trial-run automation system was taken 2 days. The system helps reduce the trial-run test period and improve the accuracy of tests.

A Study on the Optimal Voltage Regulation in Distribution Systems with Dispersed Generation Systems (분산형전원이 도입된 배전계통의 최적전압조정 방안에 관한 연구)

  • Kim Mi-Young;Oh Yong-Taek;An Jae-Yun;Kim Jae-Eon;Kim Eung_Sang;Rho Dae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.251-258
    • /
    • 2005
  • Recently, the domestic and foreign power trends are the supply of high quality power and environment conservation technology based on the new energies development. So, the dispersed generation systems, such as photovoltaic, fuel cell, and battery are to be introduced in distribution systems. According to the situation change, power of high Quality and reliability are required in distribution systems with dispersed generation. Up to now, the voltage in distribution systems are regulated by ULTC of substation and pole transformer of primary feeders. These days, Step Voltage Regulator(SVR) is getting established at distribution feeders to regulate effectively voltage of primary ffeders that voltage drop exceeds $5\%$. But, because SVR is operated independently with ULTC of substation, SVR can not take play to its full effectivity. Under these circumstances, in order to deliver suitable voltages to as many customers as possible, new optimal voltage regulation algorithms are required in distribution system. So, this paper presents optimal voltage regulation algorithm to regulate voltage effectively for ULTC and SVR in distribution systems with dispersed generation systems.

Innovative Model-Based PID Control Design for Bus Voltage Regulation with STATCOM in Multi-Machine Power Systems (STATCOM을 사용한 다기 전력 계통의 버스 전압 조절을 위한 모델 기반 PID 제어기 설계)

  • Kim, Seok-Kyoon;Lee, Young Il;Song, Hwachang;Kim, Jung-Su
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.299-305
    • /
    • 2013
  • The complexity and severe nonlinearity of multi-machine power systems make it difficult to design a control input for voltage regulation using modern control theory. This paper presents a model-based PID control scheme for the regulation of the bus voltage to a desired value. To this end, a fourth-order linear system is constructed using input and output data obtained using the TSAT (Transient Security Assessment Tool); the input is assumed to be applied to the grid through the STATCOM (STATic synchronous COMpensator) and the output from the grid is a bus voltage. On the basis of the model, it is identified as to which open-loop poles of the system make the response to a step input oscillatory. To reduce this oscillatory response effectively, a model-based PID control is designed in such a way that the oscillatory poles are no longer problematic in the closed loop. Simulation results show that the proposed PID control dampens the response effectively.

A Study on the Optimal Introduction of Step Voltage Regulator(SVR) in Distribution Feeders (고압배전선로용 선로전압조정장치(SVR)의 최적 도입방안에 관한 연구)

  • Lee Eun-Mi;Kim Mi-Young;Rho Dae-Seok;Sohn Sang-wook;Kim Jae-Eon;Park Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.610-618
    • /
    • 2004
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. Under these circumstances, to deliver reasonable voltage regulation methods in distribution systems need to be developed. So, This paper deals with optimal introduction of the line voltage regulator (SVR : Step Voltage Regulator) in power distribution systems. First, This paper investigates characteristics of SVR and performs economic evaluation of SVR's introduction by using Present Worth Method. This paper, also suggests proper location and optimal voltage regulation algorithm. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders. The simulation results using a model distribution system and real distribution systems show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

A Modeling Method of Load Section on High Voltage Distribution Line Integrated with Dispersed Generation System for Real-Time Optimal Voltage Regulation (분산형전원이 도입된 배전계통의 리얼타임 최적전압조정을 위한 부하구간 모델링방법)

  • Kim, Jae-Eon;Kim, Tae-Eung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.699-703
    • /
    • 1999
  • It is known that the LDC(Line-Drop Compensator) becomes to lose the function of proper voltage regulation for its load currents due to the real and reactive power generated by DGS(Dispersed Generation System), when DGS is introduced into the power distribution system of which the voltage is controlled by LDC. Therefore, in that case, it is very difficult to regulate the distribution line voltage properly by using LDC. One possible solution for this problem is the real-time voltage regulation method which is to optimally regulate the sending-end voltage in real-time by collecting the real-time load data of each load data of each load section between measuring points and by calculating the optimal seding-end voltage value from them. For this, we must know the real-time load data of each load section. In this paper, a modeling method of representing a load section on high voltage line with DGSs as an equivalent lumped load is proposed for gaining the real-time load data. In addition a method of locating the measuring points is proposed. Then, these proposed methods are evaluated through computer simulations.

  • PDF

Seamless Transfer of Single-Phase Utility Interactive Inverters with a Synchronized Output Regulation Strategy

  • Xiang, Ji;Ji, Feifan;Nian, Heng;Zhang, Junming;Deng, Hongqiao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1821-1832
    • /
    • 2016
  • This study presents a strategy using the synchronized output regulation method (SOR) for controlling inverters operating in stand-alone and grid-connected modes. From the view point of networked dynamic systems, SOR involves nodes with outputs that are synchronized but also display a desirable wave shape. Under the SOR strategy, the inverter and grid are treated as two nodes that comprise a simple network. These two nodes work independently under the stand-alone mode. An intermediate mode, here is named the synchronization mode, is emphasized because the transition from the stand-alone mode to the grid-connected mode can be dealt as a standard SOR problem. In the grid-connected mode, the inverter operates in an independent way, in which the voltage reference changes for generalized synchronization where its output current satisfies the required power injection. Such a relatively independent design leads to a seamless transfer between operation modes. The closed-loop system is analyzed in the state space on the basis of the output regulation theory, which improves the robustness of the design. Simulations and experiments are performed to verify the proposed control strategy.

CURRENT RESEARCH AND DEVELOPMENT ACTIVITIES ON FISSION PRODUCTS AND HYDROGEN RISK AFTER THE ACCIDENT AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION

  • NISHIMURA, TAKESHI;HOSHI, HARUTAKA;HOTTA, AKITOSHI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • After the Fukushima Daiichi nuclear power plant (NPP) accident, new regulatory requirements were enforced in July 2013 and a backfit was required for all existing nuclear power plants. It is required to take measures to prevent severe accidents and mitigate their radiological consequences. The Regulatory Standard and Research Department, Secretariat of Nuclear Regulation Authority (S/NRA/R) has been conducting numerical studies and experimental studies on relevant severe accident phenomena and countermeasures. This article highlights fission product (FP) release and hydrogen risk as two major areas. Relevant activities in the S/NRA/R are briefly introduced, as follows: 1. For FP release: Identifying the source terms and leak mechanisms is a key issue from the viewpoint of understanding the progression of accident phenomena and planning effective countermeasures that take into account vulnerabilities of containment under severe accident conditions. To resolve these issues, the activities focus on wet well venting, pool scrubbing, iodine chemistry (in-vessel and ex-vessel), containment failure mode, and treatment of radioactive liquid effluent. 2. For hydrogen risk: because of three incidents of hydrogen explosion in reactor buildings, a comprehensive reinforcement of the hydrogen risk management has been a high priority topic. Therefore, the activities in evaluation methods focus on hydrogen generation, hydrogen distribution, and hydrogen combustion.

A Study of Distribution Pricing Methods Using Yardstick Regulation (Yardstick Regulation을 이용한 배전요금 산정에 관한 고찰)

  • Sohn, Hyoung-Suk;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.646-648
    • /
    • 2003
  • Distribution pricing has been one of keystones of ongoing deregulation and privatization process in power industries. The electricity market has been established based on open access and nondiscriminatory use of the Distribution assets. As Distribution business remains as a monopoly, it is necessary to provide economic regulation. This paper focuses on the distribution pricing methods using by Incremental Marginal Cost and Yardstick Regulation.

  • PDF

A Study on the Reduction of Standby Power Consumption for Multiple Output Converters (다출력 컨버터의 대기전력 저감에 관한 연구)

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.433-440
    • /
    • 2007
  • Recently, the reduction of standby power consumption is significantly issued in electronic and electrical industry for the conservation of environment. In the case of a switched mode power supply (SMPS), it is demanded high efficiency at extremely low output power conditions by consumers. However, it is very different from high efficiency techniques at full load conditions. In addition, many SMPSs are designed as a multi-output circuit for various loads because of cost down. This circuit is difficult to implement both high efficiency and good cross regulation performance, simultaneously. In this paper, secondary side post regulator (SSPR), current mode control method, and power sequence control technique are proposed to reduce standby power consumption and to improve cross regulation performance of the multi-output SMPSs which consist of single or multiple converter. The proposed methods are analyzed by their operational principles and optimal designs verified by experimental results with 110[W] and 270[W] SMPSs.