  • The necessity of voice recording device was increased using voice signal IC with designed LSI/VLSI. The control unit which developed here voice recorder has low power dissipation, portable, and comfortable using voice source. However, the Korea voice recorder abilities far behind of foreign products for its performance and size on sailing. So we used Chua circuit to improvement voice quality abilities after minimize power supply device and circuit by designing voice recording device into lower power dissipation power circuit.

  • PDF

Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines (Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발)

  • 손수국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • This paper describes the development of a new voltage recorder for the voltage management of power distribution lines. The voltage characteristics and measurement problems for the power distribution lines are analyzed and the functions required for the recorder are discussed. Applying a dual-slope A/D converter with low noise characteristics the voltage measurement algorithm, design and implementation for the recorder are discussed. Finally, the voltage variations of long-duration over-voltages or under-voltages, and short-duration temporary interruption based on IEEE 1159 are analyzed. It is verified with the experiment.

Design and Implementation of Fault Recorder for Transmission Line Protection (송전선로 보호용 고장기록장치의 설계 및 구현)

  • Choi, Soon-Choul;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.46-52
    • /
    • 2016
  • When a fault occurs on a transmission line, it is important to identify the fault location as speedily as possible for improvement of the power supply reliability. Generally, distance to fault location is estimated by off line from the recorded data. Conventional fault recorder uses the fault data at one end. This paper deals with the design of an advanced fault recorder for enhancement accuracy of the fault distance estimation and fast detection a fault occurrence position. The major emphasis of the paper will be on the description of the hardware and software of the fault recorder. The fault locator algorithm utilizes a GPS time-synchronized the fault data at both ends. The fault data is transmitted to the other side substation through communication. The advanced fault locator includes a Power module, MPU(Main Processing Unit) module, ADPU(Analog Digital Processing Unit) module, and SIU(Signal Interface Unit) modules. The MMI firmware and software of an advanced fault recording device was implemented.

Measurement and Analysis of Surges on Information Devices Installed in a Power Substation (변전소내 정보기기에서 서지의 측정과 분석)

  • Song Jae-yong;Park Dae-won;Seo Hwang-dong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.289-294
    • /
    • 2005
  • This paper deals with the analysis results of surge voltage and current measured on information devices installed in a power substation. The power recorder to measure surge voltage and current was connected to signal lines near power transformers and switches, and the time resolution of the power recorder is 4 MS/s. Peak value of the measured surge voltage and current were ranges of 500~1,300v and 500~3,100k, respectively. During the period of measurement, over 5~10 events per day were recorded. Consequently, information devices installed in around high voltage power facilities should be designed considering the surge voltage and current caused in the condition.

Analysis of Progression of Transmission Line Fault by Fault Recorder Oscillograph (Fault Recorder 파형 분석을 통한 송전선로 고장 진전상황 분석)

  • Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.525-526
    • /
    • 2011
  • 전력계통에서 발생하는 고장 중에는 고장 후의 결과만을 가지고는 어떻게 고장이 초기에 발생하여 진전되었는지를 추정하기가 어려운 고장이 간혹 발생한다. 본 고장 분석사례는 보호계전기의 동작사항과 고장기록장치의 파형을 이용하여 송전선로에서 고저항 지락에 의한 최초의 고장이 발생 할 수 있는 가능성과, 그 고장으로 인한 파급 고장 사례를 예시하였다. 과도현상 분석 프로그램인 EMTP (Electro-Magnetic Transient Program)를 이용하여 고장 사례를 재현하여 Fault Recorder 기록과의 유사성을 확인하였다.

  • PDF

Implementation of a Portable ECG Recorder Using Wire and Wireless Communication Network (유.무선 통신망을 이용한 휴대용 심전도계 구현)

  • 김상득;배용욱;박준홍;구자헌;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.85-88
    • /
    • 2001
  • In this paper, we designed a portable ECG Recorder which can transmit collected ECG data using wire and wireless communication network. The portable ECG recorder is characterized by the small-sized and the low-power consumption. The ECG data is transmitted to a hospital using internet or PSTN. We designed the protocol in order to transmit safely The portable ECG recording system will contribute largely to telemedicine for a cardiac patient.

  • PDF

Development of new Multifunction Voltage Recorder (다기능 디지털 전압기록장치 시스템 개발)

  • Shon, Su-Goog;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

A 10-Lead Long Duration Ambulatory ECG Design -Minimizing power consumption-

  • Kim, Eung-Kyeu;Lee, Hoon-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The ECG(Electrocardiograph) ambulatory test as called Holter is performed usually to diagnose several heart diseases causing different arrhythmias. This paper exposes the insights of the design of a 10-lead ambulatory ECG recorder. Reducing the size and minimizing the power consumption of the ECG recorder are crucial to allow long recording time without causing discomfort to the patient. This paper proposes lower hardware design and differential compression algorithm to extend the maximum 72 hours recording time in consideration of smaller and light-weighted recorder size. The performance results by newly introduced compression algorithm are shown and discussed.

Fault Current Discrimination of Power Line using FCM allowing self-organization (FCM에 기반한 자가생성 지도학습알고리즘을 이용한 전력선의 고장전류 판별)

  • Jeong, Jong-Won;Won, Tae-Hyun;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.368-369
    • /
    • 2011
  • This article suggests an online-based remote fault current mode discrimination method in order to identify the causes of the power line faults with various causes. For that, it refers to existing cause identification methods and categorizes modes by fault causes based on statistical techniques beforehand and performs the pretreatment process of fault currents by each cause acquired from the fault recorder into a topological plane in order to extract the characteristics of fault currents by each cause. After that, for the fault mode categorization, it discriminates modes by each cause using data by each cause as leaning data through utilizing RBF network based on FCM allowing self-organization in deciding the middle layer. And then it tests the validity of the suggested method as applying it to the data of the actual fault currents acquired from the fault recorder in the electric power transmission center.

  • PDF

Fault Current Discrimination of Power Line using Phase Space (위상평면을 이용한 전력선의 고장전류 판별)

  • Jeong, Jong-Won;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.86-88
    • /
    • 2009
  • This article suggests an online-based remote fault current mode discrimination method in order to identify the causes of the power line faults with various causes. For that, it refers to existing cause identification methods and categorizes modes by fault causes based on statistical techniques beforehand and performs the pre-treatment process of fault currents by each cause acquired from the fault recorder into a phase space in order to extract the characteristics of fault currents by each cause. After that, for the fault mode categorization, it discriminates modes by each cause using data by each cause as leaning data through utilizing RBF network. And then it tests the validity of the suggested method as applying it to the data of the actual fault currents acquired from the fault recorder in the electric power transmission center.