• 제목/요약/키워드: power mode transition

검색결과 117건 처리시간 0.024초

수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석 (Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권4호
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법 (Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines)

  • 권국민;서용석
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

넓은 입출력 전압을 위한 LLC 공진형 컨버터의 풀 브리지-하프 브리지 모드 변환 기법 연구 (A Study on Full Bridge and Half Bridge Mode Transition Method of LLC Resonant Converter for Wide Input and Output Voltage Condition)

  • 최민영;백승우;김학원;조관열;강정원
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.356-366
    • /
    • 2022
  • This paper presents a mode transition method that applies frequency compensation technique of an LLC resonant converter for stable mode transition. LLC resonant converters used in various applications require high efficiency and high power density. However, because of circuit property, a wider voltage gain range equates to a greater circuit loss, so maintaining high efficiency at all voltage gain ranges is difficult. In this case, full bridge-half bridge mode transition method can be used, which maintains high efficiency even in a wide voltage gain range. However, this method causes damage to the circuit through overcurrent by the mode transition. This study analyzes the cause of the problem and proposes a mode transition method that applies frequency compensation technique to solve the problem. The proposed method verifies the stable transition through simulation analysis and experimental results.

Comparison of Voltage Oriented Control and Direct Power Control under Command Mode Transition for PMSG Wind Turbines

  • Kwon, Gookmin;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.173-174
    • /
    • 2016
  • This paper proposes a comparison of Voltage Oriented Control (VOC) and Direct Power Control (DPC) under command mode transition for PMSG Wind Turbines (WT). Based on a neutral point clamped three level back to back type Voltage Source Converter (VSC), proposed control scheme automatically control the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. Automatic command mode transition based on the dc-link voltage error provides a command mode changing between grid command and MPPT mode. It is confirmed through PLECS simulations in Matlab. Simulation result shows that proposed control scheme of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control scheme of MPPT with optimal torque control and VOC under a step response. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG wind turbines in order to generate a high quality output power.

  • PDF

포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석 (Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

Power Sharing Method for a Grid connected Microgrid with Multiple Distributed Generators

  • Nguyen, Khanh-Loc;Won, Dong-Jun;Ahn, Seon-Ju;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.459-467
    • /
    • 2012
  • In this paper, a grid connected microgrid with multiple inverter-based distributed generators (DGs) is considered. DG in FFC mode regulates the microgrid as a controllable load from the utility point of view as long as its output is within the capacity limit. The transition mode causes a change in frequency of microgrid due to the loss of power transferred between main grid and microgrid. Frequency deviation from the nominal value can exceed the limit if the loss of power is large enough. This paper presents a coordinated control method for inverter-based DGs so that the microgrid is always regulated as a constant load from the utility viewpoint during grid connected mode, and the frequency deviation in the transition mode is minimized. DGs can share the load by changing their control modes between UPC and FFC and stabilize microgrid during transition.

헬리콘 플라즈마의 전기적 특성 (Electrical Characteristics of Helicon Wave plasmas)

  • 윤석민;김정형;서상훈;장흥영
    • 한국진공학회지
    • /
    • 제5권1호
    • /
    • pp.85-92
    • /
    • 1996
  • The external electricla characteristics of helicon wave plasmas were measured over a wide range of RF power and magnetic filed. External parameters. such as antenna voltage , current, phase shift, and interanl parameter, electron density were measured at 7MHz, 1mTorr Ar discharge . The equivalent discharge resistance and reactance, and the power transfer efficiency were calculated through these measurements. There are a helicon mode which produces high density plasma by helicon wave and a lowmode which produces low density plasma by capaictive electric field. In case of the helicon mode, the anternna voltage and current were lower than those of the low-mode. The phase difference between voltage and current decreased suddenly at the transition point from the low-mode to the helicon mode. Equivalent resistance and power efficiency increased and reactance decreased suddenly at the transition point. These results mean that the power transperred to plasma and the nutual coupling between the antenna and plasma increase as the mode changes from the low-mode to the helicon mode.

  • PDF

무전극 램프에서의 히스테리시스와 모드 변환 (Hysteresis and Mode Transition in Electrodeless Fluorescent Lamp)

  • 이주호;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.453-453
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation: a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

E-H Mode Transition Properties of Cylindrical ICP Hg:Kr

  • Yang Jong-Kyung;Pack Kwang-Hyun;Lee Jong-Chan;Park Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, we designed a cylindrical type light source having an electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the transformer principle, an electrically equivalent circuit cylindrical type light source was analyzed. According to the parameters of electromagnetic induction, which were diameter of coil with cpO.3$\~$ 1.2mm, number of turns with 4$\~$ 12 turns, distance with 40$\~$ l20mm and RF power with 10$\~$ 150W, the electrical .md optical properties were measured. When the diameter of the coil was cp0.3mm, number of turns was 8 and distance was 40mm, and the maximum brightness of 29,730 cd/m$^{2}$ was shown with RF power l50W. The relationship between electromagnetic induction and plasma discharges was demonstrated using the mode transition from E-mode to H-mode

에너지저장장치를 갖는 단상인버터에서 매끄러운 모드절환을 위한 알고리즘 개발 (A Seamless Mode Transfer Scheme for Single Phase Inverter with ESSs)

  • 변병주;서현욱;조영훈;최규하
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.579-586
    • /
    • 2013
  • This paper proposes a mode transition algorithm between the grid-tied and the stand-alone operations for the single-phase inverter with the energy storage system. For the grid-tied operation, the dc-link voltage and the output current are required to be control. For the stand-alone mode, both the output voltage and the output current should be regulated. In order to mitigate a falling-off in control performance during transients in mode change, the load power estimation and the current selection schemes are proposed. The proposed method allows an optimized current reference is selected to reduce an output voltage drop and an excessive over-current in transient. To verify the effectiveness of the proposed method, both the simulation and the experiments for a 3kW single-phase inverter with the energy storage system have been conducted. From the results, it has been confirmed that the proposed method reduces a transient error as well as implementing smooth mode transition.