DOI QR코드

DOI QR Code

A Seamless Mode Transfer Scheme for Single Phase Inverter with ESSs

에너지저장장치를 갖는 단상인버터에서 매끄러운 모드절환을 위한 알고리즘 개발

  • Received : 2013.09.04
  • Accepted : 2013.10.22
  • Published : 2013.12.20

Abstract

This paper proposes a mode transition algorithm between the grid-tied and the stand-alone operations for the single-phase inverter with the energy storage system. For the grid-tied operation, the dc-link voltage and the output current are required to be control. For the stand-alone mode, both the output voltage and the output current should be regulated. In order to mitigate a falling-off in control performance during transients in mode change, the load power estimation and the current selection schemes are proposed. The proposed method allows an optimized current reference is selected to reduce an output voltage drop and an excessive over-current in transient. To verify the effectiveness of the proposed method, both the simulation and the experiments for a 3kW single-phase inverter with the energy storage system have been conducted. From the results, it has been confirmed that the proposed method reduces a transient error as well as implementing smooth mode transition.

Keywords

References

  1. D.J. Lee, L. Wang, "Small-Signal Stability Analysis of an Autonomous Hybrid Renewable Energy Power Generation/Energy Storage System Part I: Time-Domain Simulations," IEEE Trans. on energy conversion, Vol. 23, pp. 311-320, 2008. https://doi.org/10.1109/TEC.2007.914309
  2. M.N. Arafat, S. Palle, Y. Sozer, I. Husain, "Transition Control Strategy Between Standalone and Grid-Connected Operations of Voltage-Source Inverters," IEEE Trans. on Industry Applications, Vol. 48, pp. 1516-1525, 2012. https://doi.org/10.1109/TIA.2012.2210013
  3. T.S. Hwang, S.Y. Park, "A Seamless Control Strategy of a Distributed Generation Inverter for the Critical Load Safety Under Strict Grid Disturbances," IEEE Trans. on Power Electronics, Vol. 28 pp. 4780-4790, 2013. https://doi.org/10.1109/TPEL.2012.2236578
  4. J.B. Kwon, S.J. Yoon, S.W. Choi, "Indirect Current Control for Seamless Transfer of Three-Phase Utility Interactive Inverters," IEEE Trans. on Power Electronics, Vol. 27 pp. 773-781, 2012. https://doi.org/10.1109/TPEL.2011.2161335
  5. H..M. Oh, S.W. Choi, T. H. Kim, "Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load," Journal of the Korean Institute of IIIuminating and Electrical Installation Engineers, pp. 315-321, Aug. 2012. https://doi.org/10.6113/TKPE.2012.17.4.315
  6. W.P. Zhang, D.H. Xu, X. Li, R. Xie, H.J. Li, "Seamless Transfer Control Strategy for Fuel Cell Uninterruptible Power Supply System," IEEE Trans. on Power Electronics, Vol. 28, pp. 717-729, 2013. https://doi.org/10.1109/TPEL.2012.2204777
  7. G.H. Choe, B.G. D, Y.J. Lee, D.H. Han, B.H. Jeong, H.S. Kim, "Characteristics Analysis of RPV and AFD for Anti-Islanding in Active Method," The transactions of korea institute of power electronics, Vol. 2, pp. 160-167, April 2009.
  8. H.S. Kim, H.G. Kim, G.H Choe, J.C Kim, Y.H. Choi, "An Analysis and Design of RPV and AFD Method for Anti-Islanding of Single-Phase UIPV System under The Test Condition Recommended by IEEE 929-2000," The transactions of korea institute of power electronics, Vol. 1, pp. 37-49, Feb. 2007.
  9. H.S. Kim, "Design of A New Controller for 3-Phase Utility Interactive Photovoltaic System," Ph. D. Dissertation, Konnkuk University, 1998.
  10. J.S. Gho, "Optimal Design of Controller for PWM Converter and Inverter System," Ph. D. Dissertation, Konnkuk University, 2001.
  11. J.S. Cho, "A Study on Modified Deadbeat Digital Controller for Constant Voltage Output Characteristics of 3-Phase UPS," Ph. D. Dissertation, Konnkuk University, 1999.