• Title/Summary/Keyword: power meter

Search Result 532, Processing Time 0.029 seconds

Microwave Dielectric Absorption Spectroscopy Aiming at Novel Dosimetry Using DNAs

  • Izumi, Yoshinobu;Hirayama, Makoto;Matuo, Youichirou;Sunagawa, Takeyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.21-25
    • /
    • 2017
  • Background: We are developing L-band and S-band microwave dielectric absorption systems aiming novel dosimetry using DNAs, such as plasmid DNA and genomic DNA, and microwave technology. Materials and Methods: Each system is composed of a cavity resonator, analog signal generator, circulator, power meter, and oscilloscope. Since the cavity resonator is sensitive to temperature change, we have made great efforts to prevent the fluctuation of temperature. We have developed software for controlling and measurement. Results and Discussion: By using this system, we can measure the resonance frequency, f, and ${\Delta}Q$ (Q is a dimensionless parameter that describes how under-damped an oscillator or resonator is, and characterizes a resonator's bandwidth relative to its center frequency) within about 3 minutes with high accuracy. Conclusion: This system will be expected to be applicable to DNAs evaluations and to novel dosimetric system.

The embodiment of distribution automation based internet networks (인터넷 기반의 배전자동화 구현)

  • Lee, H.S.;Yeo, J.K;Kim, J.J.;Lee, H.H.;Ha, B.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2588-2590
    • /
    • 2001
  • Distribution ayatems at the final stage of the power supply process are directly and extensively connected to customers. There are growing demands for more efficient operation and higher reliability. This paper describes the embodiment of distribution automation using internet networks. We suggest the large region distribution server system for distribution automation functions in local area network, automated meter reading system and directed load control system with by-directional communication.

  • PDF

Development of Operation Software for Electric Power Meter (전자식 전력량계 운용프로그램 개발)

  • Jang Moonjong;Kim S.I.;Go J.M.;Oh D.Y.;Yu I.H.;Lee J.K.
    • Annual Conference of KIPS
    • /
    • 2004.11a
    • /
    • pp.705-708
    • /
    • 2004
  • 한국전력공사는 검침업무의 복잡성을 단순화하고 유지보수에 따른 비용절감 등의 이유로 특정 제조회사의 통신방식이나 데이터구조 등에 구애받지 않도록 표준화된 전자식 전력량계의 통신프로토콜과 운용프로그램 개발을 수행하였다. 전자식 전력량계의 통신프로토콜을 통일하고 표준화된 검침용 운용프로그램을 사용함으로써 검침원에게는 다양한 검침용 운용프로그램 사용법을 익혀야하는 불편함을 없애고 각사별 검침용 장비의 유지관리에 따른 비용을 절감할 뿐만 아니라 저비용으로 보다 신뢰성 있는 원격검침 시스템 구축이 용이할 것으로 기대된다. 본 논문에서는 전자식 전력량계의 통신 프로토콜과 데이터구조, 운용프로그램 설계 및 구현에 대해 소개한다.

  • PDF

The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor (디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Choi, Jang-Yong;Seok, Dea-Woo;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

Application of Demand Controller for Summer Peak Demand Shaving and Valuation of its Economical Efficiency (하계최대부하 억제를 위한 디맨드 콘트롤러 적용사례 및 경제성 평가)

  • Kang, W.G.;Lee, G.W.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.720-723
    • /
    • 1996
  • The recent summer power peak crisis has been caused by excessive use of cooling loads at daily peak time in summer. The yearly load shape of KEPCO has gradually became very steep valley. Under this situation, more efficient DSM(Demand Side Management) tools are fully required for summer peak clipping and shaving. In this paper, the KEPCO's Jeju-Do model project for DSM, especially for Demand Controller, is presented. Demand Controller was evaluated to have the very high economical efficiency against the investment in equipment, as compared with another DSM tools. There were some serious problem to apply Demand Controller to many customers in the aspect to synchronization with KEPCO's watthour meter. But these problems have solved by Keyin's new Demand Controller using vision algorithm.

  • PDF

A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System (분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구)

  • Shin, Dong-Yeol;Park, Yong-Woo;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

Development of Electromagnetic Wave Immunity Test system (전자파내성시험용 측정시스템의 개발에 관한 연구)

  • 정세모;김동일;배대환
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.2
    • /
    • pp.97-107
    • /
    • 1996
  • The method of Electromagnetic Wave Immunity Test is continuously endeavored by IEC and CISPR as international unification, but it has not been established yet. The main reason is why it is difficult to obtain the measurement method and normalization of threshold to find out the complicated parameters for Electromagnetic Wave immunity Test. So far, thus, the Electromagnetic Wave Immunity Test is carried out case by case as the electromagnetic environment, which is set up Electromagnetic Wave Immunity Test. This study has developed an algorithm and measurement software suitable for IEC1000-4 Regulations, where a ready-made Amplifier, and Signal Generator have been used and an interconnecting Interface Board has been constructed for connecting with the other apparatuses, i.e., RF Switch, Power Meter, Field Sensor, Pre-Amp., etc. Therefore, we have achieved the aim to develop an automated software using OOP method and the measurement system.

  • PDF

Electrical Characteristics of Optical Current Transducer on Gas Insulated Switchgear (GIS용 광CT의 전기적 특성)

  • Lee, Su-Woong;Lee, Sung-Gap;Noh, Hyeon-Ji;Ahn, Byeong-Rib;Won, Woo-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.319-320
    • /
    • 2007
  • We researched basic study about electrical characteristics of Zinc Selenide (Faraday Cell), which is known for various temperature of good-performance, that applied measuring current or protecting instrument by Optical Current Transducer, on Gas Insulated Switchgear. Measuring System consists of VCSEL produced 850nm IR Laser, Pin Photo Diode made of GaAs surveyed as Optical Power Meter, and Optical Fibers specified Multi-mode. We observed optical output changes during measurement of currents increasing by 100[A] in range from 0[A] to 1,000[A] and set temperature condition increasing by $5[^{\circ}C]$ in a range from $30[^{\circ}C]\;to\;60[^{\circ}C]$.

  • PDF

Analysis of Characteristics of Residential Distribution Line for PLC Modem Design (PLC 모뎀설계를 위한 옥내 배선 특성분석)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1524-1526
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper and Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and the averaged analysis data are shown in the tables. The measured results no different from the calculated values with using conventional formula due to the line arrangement neglected factors, complex permittivity, and etc. Also, this paper describes many kinds of lines and wiring figures of domestic construction. Finally, it is utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

  • PDF

Design and evaluation of BPLC-based meter reading network via underground MV line (지중전력선을 경유한 BPLC 원격검침 통신망 설계 및 성능평가)

  • Baek, Jongmock;Ju, Seongho;Lim, Yonghun;Choi, Moonsuk
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.304-305
    • /
    • 2010
  • 전력선통신을 이용한 원격검침 시스템의 구축이 시범사업을 넘어 상용화 수준으로 확대되어가고 있으나 현재까지는 주로 주상변압기에서 댁내 수용가정간에 고속전력선 통신칩을 사용하여 셀 토폴로지형태로 100가구전후 원격검침망을 구성하였다. 지중구간의 전력선은 가공선로와는 많은 다른 통신채널 특징을 가지며 지중화된 구간은 대도시 밀집지역에 주로 시설되기 때문에 원격검침시스템 구성시 가공구간보다 경제적인 측면에서나 검침자동화 확산 측면에서나 좋은 효과를 볼 수 있다. 본 논문에서는 지중고압선을 경유하는 원격검침망의 모델을 설계하고 시범운영을 통해 성능을 시험하였다.

  • PDF