• Title/Summary/Keyword: power meter

Search Result 532, Processing Time 0.033 seconds

Optimation of Reactor Control System by using Random Noise (랜덤 잡음을 이용한 원자로의 제어계 최적안전운전에 관한 연구 (1))

  • 고병준;신재인
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 1969
  • Reactor power frequency spectrum measurements at various power levela-OW, 1KW, 50KW, 100KW were made with TRIGA-MARK-II. An ion chamber was exposed to reactor flux, and the fluctions in its output current were analyed in a tunable bandpass filter to get the frequency spectrum of these fluctuation. The measured frequency spectrum of pile determined the modules of modules of zero power transfer function and indicated a prompt neutron mean life time of (7.90$\pm$1.62)X10 sec based on effective delayed neutron faction of 0.0075. The absolute value of reactor power obtained by noise analysis agreed within 5% with the power meter indication at the power below 10Kw.

  • PDF

The study of the remort power analysis and control system using power line communication (전력선 통신을 이용한 원격 전력분석 및 제어시스템에 관한 연구)

  • Choi, Won-Ho;Lee, Hoo-Chan;Park, Chong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.211-213
    • /
    • 2005
  • RPA(Remelt Power Analysis)and RC(Remote Control) System have been researched from former several decade for a various power rate system a efficent power service and rising of personal expenses, etc. But the existing RPA and RC System have disadventage which are complex and high cost to install an individual communication network of electricity company This paper proposed a new type of RPA and RC System using PLC with Internet. and made components for proposal system so we made the PLC modem, the digital watt-hour meter with a build in PLC modem and the softwere on server computer for establishing the proposal system. The bit rate of the proposed system is about 4800bps.

  • PDF

Development of a Portable ELF Electric Field Meter (휴대용 극저주파 전장측정기 개발)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • This paper dealt with the developed portable electric field meter which consisted of planar-type sensor, analog amplifier with gain controller, A/D convertor, and display unit. The principle of the planar-type sensor for detecting time-varying electric field of extremely low frequency (ELF) bandwidth was described, and a calibration system using cylindrical guard electrodes and parallel-plate electrodes was proposed. From the calibration experiment, the frequency bandwidth and the sensitivity of the developed electric field meter was $17[Hz]{\sim}7[kHz]$, and 4.45[mV/V/m], respectively. Also it can measure the electric field strength up to 10[kV/m], and the measured result was displayed on the liquid crystal display in digit. The electric field meter can be widely applied to measure electric field strength radiated from power lines, computers, and home appliances such as hair dryer, heater, etc.

  • PDF

Fabrication of 250 m class Bi-2223/Ag HTS Tapes (250 m 급 Bi-2223/Ag 고온 초전도선재 제조)

  • Ha, H.S.;Oh, S.S.;Ha, D.W.;Jang, H.M.;Kim, S.C.;Song, K.J.;Park, C.;Kwon, Y.K.;Ryu, K.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

Analysis of Factors Driving the Participation of Small Scale Renewable Power Providers in the Power Brokerage Market (소규모 재생발전사업자의 중개시장참여 촉진요인 분석)

  • Li, Dmitriy;Bae, Jeong Hwan
    • New & Renewable Energy
    • /
    • v.18 no.3
    • /
    • pp.32-42
    • /
    • 2022
  • Rapid spread of intermittent renewable energy has amplified the instability and uncertainty of power systems. The Korea Power Exchange (KPX) promoted efficient management by opening the power brokerage market in 2019. By combining small-scale intermittent renewable energy with a flexible facility through the power brokerage market, the KPX aims to develop a virtual power plant system that will allow the conversion of existing intermittent renewable energy into collective power plants. However, the participation rate of renewable power owners in the power brokerage market is relatively low because other markets such as the small solar power contract market or the Korea Electric Power Corporation power purchase agreement are more profitable. In this study, we used a choice experiment to determine the attributes affecting the participation rate in the power brokerage market for 113 renewable power owners and estimate the value of the power brokerage market. According to the estimation results, a low smart meter installation cost, low profit variations, long contract periods, and few clearances increased the probability of participation. Moreover, the average value of the power brokerage market was estimated to be 2.63 million KRW per power owner.

Adaptive algorithm for optimal real-time pricing in cognitive radio enabled smart grid network

  • Das, Deepa;Rout, Deepak Kumar
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.585-595
    • /
    • 2020
  • Integration of multiple communication technologies in a smart grid (SG) enables employing cognitive radio (CR) technology for improving reliability and security with low latency by adaptively and effectively allocating spectral resources. The versatile features of the CR enable the smart meter to select either the unlicensed or the licensed band for transmitting data to the utility company, thus reducing communication outage. Demand response management is regarded as the control unit of the SG that balances the load by regulating the real-time price that benefits both the utility company and consumers. In this study, joint allocation of the transmission power to the smart meter and consumer's demand is formulated as a two stage multi-armed bandit game in which the players select their optimal strategies noncooperatively without having any prior information about the media. Furthermore, based on historical rewards of the player, a real-time pricing adaptation method is proposed. The latter is validated through numerical results.

A Discussion on the Radiation Efficiency Measurement of Porous Surface Flames (다공성 표면 화염의 복사열효율측정에 관한 논의)

  • Jeong, Hwanghui;Sim, Keunseon;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.157-159
    • /
    • 2014
  • This article describes an investigation of basic combustion characteristics of radiant burner with various firing rate and equivalence ratios in porous metal. As a main experimental condition, firing rates and equivalence ratios each were adjusted from 204 to $408kW/m^2$ and 0.6 to 1.3. The purpose of this study is to investigate radiation efficiency using two experiment methods. The first way is to calculate the radiation efficiency by measuring the temperature of the burner surface, and the second is to compute the radiation efficiency by measuring the radiation intensity of the burner surface with a radio meter. The value of the radiation efficiency did not exactly match in the two cases. But we figured out that in accordance with increasing heat power, radiation efficiency was decreased. And additional complementary experiment on the relationship between these values is needed.

  • PDF

Development of Watt-Hour Meter Exchange Equipment without Outage (전력량계 무정전 교체장치 개발에 관한 연구)

  • Jung, Tae-Hoon;Cho, Sung-Min;Shin, Hee-Sang;Lee, Hee-Tae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.99-103
    • /
    • 2009
  • This paper presents equipment that can exchange watt-hour meters without outage for customers, It is simpler than other methods to avoid outage during exchange. Furthermore, it has protective function to ensure customer's facility from engineer mistake. Because of good point mentioned above, it can improve efficiency and safety. Adopting developed equipment can ensure continuous electric power supply to customers.

위험전압 측정기의 설계 및 제작

  • Jang, Un-Yong;Park, Dae-Won;Han, Ju-Seop;Gil, Gyeong-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.25-25
    • /
    • 2010
  • This paper describes the design and fabrication of a Risk Voltage Meter (RVM) which can analyze the step and touch voltages in grounding systems. The meter consists of a sine-wave power source which generates up to 300 [$V_{rms}$] in ranges of 45 [Hz]~1 [kHz], a 8 Ch. data acquisition module, and a personal computer. Also, a noise elimination method by a digital band-pass filter during measurement is proposed.

  • PDF

Implematation of AMR system using Power ine Communication

  • Park, Byoung-Seok;Hyun, Duck-Hwa;Jang, Mun-Jeong;Lim, Young-Hoon;Cho, Sung-U
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.119.4-119
    • /
    • 2001
  • It is the advantage of PLC that digitalization and networking of existing facility can be organized at low price because there is no need further construction of communication line considering that home appliance, information device and various kind of control devices are digitalized at low price. Moreover, AMR(Automatic Meter Reading) is very attractive to utility company because not only does it reduce the cost of reading meter, but also it can control and monitor the demand for energy. So, it can solve the consumers problem best and easily. It also can be easily realized that the utilities can expand there areas to values-added service through existing network. The performance of the PLC modem which is being developed now is not moven enough and much more test for outdoor modem is needed especially. Therefore, we, KEPRI, concentrate our efforts on configuring AMR system for test and investigation of the actual performance of various kinds ...

  • PDF