• Title/Summary/Keyword: power meter

Search Result 532, Processing Time 0.031 seconds

Clustering of Smart Meter Big Data Based on KNIME Analytic Platform (KNIME 분석 플랫폼 기반 스마트 미터 빅 데이터 클러스터링)

  • Kim, Yong-Gil;Moon, Kyung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • One of the major issues surrounding big data is the availability of massive time-based or telemetry data. Now, the appearance of low cost capture and storage devices has become possible to get very detailed time data to be used for further analysis. Thus, we can use these time data to get more knowledge about the underlying system or to predict future events with higher accuracy. In particular, it is very important to define custom tailored contract offers for many households and businesses having smart meter records and predict the future electricity usage to protect the electricity companies from power shortage or power surplus. It is required to identify a few groups with common electricity behavior to make it worth the creation of customized contract offers. This study suggests big data transformation as a side effect and clustering technique to understand the electricity usage pattern by using the open data related to smart meter and KNIME which is an open source platform for data analytics, providing a user-friendly graphical workbench for the entire analysis process. While the big data components are not open source, they are also available for a trial if required. After importing, cleaning and transforming the smart meter big data, it is possible to interpret each meter data in terms of electricity usage behavior through a dynamic time warping method.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

The feeder automation using the switches with multi functions (다기능개폐기를 이용한 선로운전자동화)

  • Song, Byong-Kwon;Hong, Soon-Hak;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.183-186
    • /
    • 1992
  • The distribution automation functions include feeder automation, data acquisition and processing, remote meter reading and load management. This report explains the function of feeder automation and the accomplishment method of feeder automation using the switches of distribution system with multi functions.

  • PDF

Development of Telemetering and Control system using PLC and Web (전력선통신과 인터넷을 이용한 원격제어 및 검침구현)

  • 최원호;박종연
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.282-290
    • /
    • 2003
  • AMR(Automatic Meter Reading) and RC(Remote Control) System have been researched from former several decade for a various power rate system, a efficient power service and rising of personal expenses, etc. But the existing AMR and RC System have disadvantage which are complex and high cost to install an individual communication network of electricity company. This paper proposed a new type of AMR and RC System using PLC with Web. and made components for proposal system. Most customer who live in apartment have an internet cable in the Republic of Korea. Therefore there is no more installation component for communication in proposal system at the apartment, except Web server system and PLC modem. so we made the PLC modem the digital watt-hour meter with a build in PLC modem and the software on server computer for establishing the proposal system.

Performance of Equalizer Schemes in Power Line Communication Systems for Automatic Metering Reading (자동 원격검침을 위한 전력선 통신 시스템에서의 등화 기법 연구)

  • Kim, Yo-cheol;Bae, Jung-Nam;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • In this paper, we propose and analyze the equalizer schemes, zero-forcing (ZF) and minimum mean square error (MMSE) in power line communication (PLC) system for automatic meter reading (AMR). For efficient implementation of AMR system with PLC, effects of impulsive noise and multipath channel should be mitigated. To overcome these effects, the above equalizer schemes are employed. System performance is evaluated in term of bit error rate. From simulation results, it is confirmed that the equalizer can significantly improve bit error rate (BER) performance in PLC system, and MMSE equalizer provides better performance than ZF scheme. The results of this paper can be applied to AMR system as well as various smart grid services using PLC.

Implement of Watt-Hour Meter Monitoring System by Internet Map Based GUI using Power Line Communication (전력선 통신을 이용한 인터넷 맵 연동 전자계량기 모니터링 시스템 구현)

  • Park, Keun-Soo;Lee, Young-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1435-1441
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system applying a Power Line Communication (PLC) MODEM and a Data Concentrator Unit (DCU) which can apply to Internet map based Graphical User Interface (GUI). The PLC MODEM is profitable by saving the cost of installing dedicated wiring, and Internet map GUI also is able to contribute an easy access to monitoring system for non export users. This system makes it possible to monitor the amount of electricity of previous/ current month metering data via Internet mapping service. The implement system can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.

A Study on Correlation between Power of Trunk Flexors, Extensors and Lumbar Lordotic Angle in Normal Adults (정상 성인에서 체간 굴근, 신근의 근력과 요추 전만각의 상관관계에 관한 연구)

  • Choi, Bo-Mi;Yi, Jeong-Min;Kim, Hyun-Soo
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.2
    • /
    • pp.39-52
    • /
    • 2012
  • Objectives : The purpose of this study was to investigate the correlation between lumbar lordotic angle and the power of trunk flexors, extensors in normal adults Methods : 34 normal participants participated in this study. Their lumbar lordotic angle(L1-S1 Cobb's angle and L1-L5 cobb's angle) was measured by x-ray taken on lateral direction, erect cross-arm position. And muscle power of trunk flexors and extensors of each participant measured using Cybex HUMAC NORM. Results : 1. The average of L1-S1 Cobb's angle was $47.21{\pm}8.88^{\circ}$ and the average of L1-L5 Cobb's angle was $36.32{\pm}9.62^{\circ}$(Table IV). 2. The average ratio of trunk flexors/extensors was $6.44{\pm}19.31%$(Table V). The average power of the trunk flexors was $165.18{\pm}55.05$(Newton-Meter/kg), and the power of trunk extensors was $257.18{\pm}85.53$ (Newton-Meter/kg)(Table VI). 3. Lumbar lordotic angle has no relation to the ratio of trunk flexors/extensors(Table VII, Fig. 4). 4. Lumbar lordotic angle has no relation to both the power of the trunk flexors and extensors(Table VIII, Fig. 5, Fig. 6). Conclusions : These results suggest that the lumbar lordotic angle measured by radiograph could not evaluate the power and ratio of trunk flexors, extensors.

  • PDF

Development of Tobacco Ripeness Grading Meter Using the Color Sensor (칼라센서를 이용한 담배 완숙도의 식별장치 개발)

  • 이대원;이용국
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 1994
  • A tobacco ripeness grading meter was designed and constructed using the color sensor, its performance was evaluated. A degree of ripeness grading of a leaf is very closely related to the measured tobacco leaf color. Measuring the small amount of the reflectance precisely depends on the apparatus including color sensor, light source, detector sensitivity, and geometric characteristics of appratus. To analyze and minimize the variational effects, experiments to select the proper condition were performed. Because of the combined effect mentioned above, the system has some variation on its response. Basis on the results of the experiments, prototype was developed and interfaced to a computer system. The main components of prototype included a tungsten lamp as a light source, Amorphous full color sensor with three filters, regulated D.C. power supply, OP - AMP(741 TC) for amplification, AR - B3001 board for interfacing to a computer with analog to digital conversion, and a compatible IBM PC XT computer. The experimental results of the developed ripeness tobacco leaf measurement system are summarized as following: [1] The output readings of ripeness grade meter for tobacco leaf, which is based on harvesting time, showed the apparent difference in variety of different quality. It was considered suitable that three filters(red, green, blue) in Amorphous full color sensor could be used in four different ripeness degree measurement of tobacco leaf. [2] The output readings of ripeness grade meter for tobacco leaf, which is based on government procurement, showed apparent difference in variety of different quality. Tobacco leaf varieties to stalk position are divided into tips, leaf, cutters, and primings, It is considered suitable that only red filter in the sensor could be used to classify the grade of tobacco leaf within the same kind tobacco stalk. However, the ripeness grade meter was not adequate to classify all the tobacco grades in the four different tobacco leaves.

  • PDF

Maximum Power Analysis Simulator Development & Lighting Installation Control Simulation (최대전력 분석시뮬레이터 개발 및 조명설비 제어 시뮬레이션)

  • Chang, Hong-Soon;Han, Young-Sub;Soe, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.95-99
    • /
    • 2013
  • The maximum power analysis simulator took advantage of the facilities and power consumption reduction simulator test scenario development and testing of improvement in the scenario. As a maximum demand power controller, Maximum power analysis simulator performs control and disperasion of maximum demand power by calculating base power, load forecast, and present power which are based on signal of watt-hour meter to keep the electricity under the target. In addition, various algorithms to select appropriate control methode on each of the light installations through the peak demand power is configured to management. The simulation shows the success of control power for the specified target controlled by five sequential lighting installations.

A Study on Smart Peak Power Control System (스마트 최대 전력 관리 시스템 알고리듬 연구)

  • Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.227-228
    • /
    • 2013
  • The paper is related to smart maximum power system based on program logic. Especially, this system compares the total demand power with the target power by using the signal from the digital kilo watt meter. Based on the power information by the maximum power control equipment the consumed future power is anticipated. In addition, through consumed future power the controllable target power is set, and it applies on the maximum power control equipment. User or manager would control the load efficiently through the simple programming which could control load based on the control sequence and relay. So this system could control load more efficient and stable. Also the conventional load control circuit is not needed. Therefore, it is possible to improve the simple system configuration, which is resulted in cost effective and time saving. So this system is anticipated on time and coast.

  • PDF