• 제목/요약/키워드: power means

검색결과 2,334건 처리시간 0.034초

Solar Inverter with Grid Power Generation

  • Suchitra Khoje;Govind Wanje;Ramesh Mali
    • International Journal of Computer Science & Network Security
    • /
    • 제23권9호
    • /
    • pp.162-165
    • /
    • 2023
  • Power can be generated from either renewable or non-renewable sources. Renewable sources are liked to maintain a strategic distance from contamination emanation and rely on upon fossil energizes which is decreasing day by day. The proposed sun powered vitality transformation unit comprises of a sun oriented exhibit, Bidirectional DC-DC converter, single stage inverter and AC. The inverter changes over DC control from the PV board into AC power and offered it to the heap which is associated with the lattice. The photovoltaic sun powered vitality (PV) is the most direct approach to change over sunlight based radiation into power and depends on the photovoltaic impact. The most extreme power point following of the PV yield for all daylight conditions is a key to keep the yield control per unit cost low for fruitful PV applications. Framework associated PV frameworks dependably have an association with people in general power matrix by means of an appropriate inverter in light of the fact that a PV module conveys just dc power. This project presents the new design, Development and Performance Analysis of a Grid Connected PV Inverter. Demonstrate that the proposed framework can lessen the Energy Consumption radically from the power board and give a solid support to the Grid.

Performance Comparison of Two Wind Turbine Generator Systems Having Two Types of Control Methods

  • Saito, Sumio;Sekizuka, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.92-101
    • /
    • 2009
  • The purpose of this paper is to gain a greater understanding of the performance of practical wind turbine generating systems with differing output power controllers and controlling means for wind turbine speed. Subjected wind turbines, both equipped with an asynchronous power generator, are located at two sites and are defined as wind turbine A and wind turbine B in this study, respectively. Their performance differences are examined by measuring wind speed and electric parameters. The study suggests that both wind turbines have a clear linkage between current and output power fluctuations. Comparison of the fluctuations to wind speed fluctuation, although they are triggered primarily by wind speed fluctuation, clearly indicates the specific behaviors inherent to the respective turbine control mechanisms.

A Primary-Side-Assisted Zero-Voltage and Zero-Current Switching Three-Level DC-DC Converter

  • Jeon S. J.;Canales F.;Barbosa P. M.;Lee F. C.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.227-231
    • /
    • 2001
  • A new primary-side-assisted zero-voltage and zero-current switching (ZVZCS) three-level DC-DC converter with flying capacitor is proposed. The three-level converters are promising in high voltage applications, and ZVZCS is a very effective means for reducing switching losses. The proposed DC-DC converter uses only one auxiliary transformer and two diodes to obtain ZCS for the inner leg. It has a simple and robust structure, and offers soft-switching capability even in short-switching conditions. The proposed converter was verified by experiments in a 6KW prototype designed for communication applications and operating at 100kHz.

  • PDF

원자력 발전소 온배수 이용 농산물에 대한 소비자 인식조사 (A Study on the Consumers' Perception of Agricultural Products Using Nuclear Power Plants Waste Heat)

  • 허승욱
    • 한국유기농업학회지
    • /
    • 제26권3호
    • /
    • pp.369-379
    • /
    • 2018
  • This study examines consumers' perception of agricultural products using nuclear power plants waste heat. This study surveyed 348 consumers and found that presenting information about safety of waste heat utilization increased appropriacy of waste heat; after providing the information, the percentage of respondents in favor of using waste heat increased 27.5% point from 38.3% to 65.8%. The most important reason against using waste heat was because it threatened the safety of agricultural products, and the most important reason for its support was to reduce farm production costs. The purchase intention for agricultural products using waste heat had risen by at least 10% point after providing the information about safety of waste heat. Those means that it important provision of accurate and reliable information on the safety of waste heat to encourage the utilization of waste heat from nuclear power plants. Purchase intention for flowers using waste heat was most, followed by vegetables, fruits (including fruits and vegetables).

소비자 감성 평가를 통한 냉장고 Sound Power Spectrum Guideline (Sound Power Spectrum Guideline for a Refrigerator based on Subjective Evaluation)

  • 이진경;조경숙;이제원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.634-637
    • /
    • 2007
  • A weighted sound pressure level has been used to evaluate sounds test or sound quality test for a refrigerator up to present but the customer had different satisfactions of refrigerator sounds with different listening position. It means that there was a sound directivity caused by a position of fan or compressor. In this paper, we proposed a sound power spectrum guideline that represents total sound of refrigerator.

  • PDF

An Investigation of Thermal Margin for External Reactor Vessel Cooling(ERVC) in Large Advanced Light Water Reactors(ALWR)

  • Park, Jong-Woon;Jerng, Dong-Wook
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.473-478
    • /
    • 1997
  • A severe accident management strategy, in-vessel retention corium through external reactor vessel cooling(ERVC) is being studied worldwide as a means to prevent reactor vessel failure following a core melt accident. An evaluation of feasibility of this ERVC for a large Advanced Light Water Reactor (ALWR) is presented. To account for the coolability of corium and metal in the reactor vessel, a thermal analysis is performed using an existing method. Results show that the peak heat flux along the inner surface of the reactor vessel lower head has a relatively smaller margin than a small capacity reactor such as AP600 in regards with the critical heat flux attainable at the outer surface of the reactor vessel lower head.

  • PDF

개선된 적응 예측 필터를 이용한 새로운 능동전력필터용 기준신호발생기 (Novel Reference Signal Generator for Active Power Filter Using Improved Adaptive Predictive Filter)

  • 배병열;김희중;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.212-216
    • /
    • 2003
  • The performance of active power filter depends on the inverter characteristic, the control method, and the accuracy of reference signal generator. The accuracy of reference generator is the most critical item to determine the performance of active power filter. This paper introduces a novel reference signal generator composed of improved adaptive predictive filter. The performance of proposed reference signal generator was verified by means of simulation with MATLAB. The simulation result confirm that the proposed reference signal generator can be utilized for the active power filter.

  • PDF

Improved Pre-prepared Power Demand Table and Muller's Method to Solve the Profit Based Unit Commitment Problem

  • Chandram, K.;Subrahmanyam, N.;Sydulu, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.159-167
    • /
    • 2009
  • This paper presents the Improved Pre-prepared Power Demand (IPPD) table and Muller's method as a means of solving the Profit Based Unit Commitment (PBUC) problem. In a deregulated environment, generation companies (GENCOs) schedule their generators to maximize profits rather than to satisfy power demand. The PBUC problem is solved by the proposed approach in two stages. Initially, information concerning committed units is obtained by the IPPD table and then the subprob-lem of Economic Dispatch (ED) is solved using Muller's method. The proposed approach has been tested on a power system with 3 and 10 generating units. Simulation results of the proposed approach have been compared with existing methods and also with traditional unit commitment. It is observed from the simulation results that the proposed algorithm provides maximum profit with less computational time compared to existing methods.

IEC 61850 변전자동화시스템 실증시험에 관한 연구 (A Study on the Field Test of IEC 61850 based Substation Automation System)

  • 이남호;장병태;김병헌;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.250_251
    • /
    • 2009
  • IEC 61850 based substation automation system mainly consists of human machine interface as a client and a various of IEDs as a server. Both of them should require the field testing for performance verification including IEC 61850 communication services. This means that the test can assure the interoperability of IEC 61850 based substation automation system consisted of multi vendor's products. This paper shows a research result on the field test of the IEC 61850 based HMI and IEDs. And it proposes some engineering solutions for the system implementation.

  • PDF

Microscopic Dynamic Voltage Scaling(DVS) 기반 저전력 MPEG-2 AAC 알고리즘 최적화 구현에 관한 연구 (Low Power Optimization of MPEG-2 AAC with Microscopic Dynamic Voltage Scaling(DVS))

  • 이은서;이재식;장태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.428-430
    • /
    • 2006
  • This paper proposes a new means of performance optimization for multimedia algorithm utilizing the Microscopic DVS (Dynamic Voltage Scaling). The Microscopic DVS technique controls the operating frequency and the supply voltage levels dynamically according to the processing requirement for each frame of multimedia data. The huffman decoding algorithm of MPEG-2 AAC audio decoder is optimized to maximize the power saving efficiency of Microscopic DVS technique. The experimental results show the reduction of computational complexity by more than 30% and the reduction of power consumption by more than 17% compared with those of the conventionally fast method.

  • PDF