• Title/Summary/Keyword: power means

Search Result 2,331, Processing Time 0.031 seconds

A Study on Solution against Core Saturation Instability at HVDC Converter

  • Yang, Byeong-Mo;Kim, Chan-Ki;Koh, Bong-Eun;Moon, Young-Hyun
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.297-304
    • /
    • 2002
  • The paper identifies a severe form of core saturation instability in a DC/AC interaction system. It then seeks solutions to the problem by HVDC control means. This is achieved by a proper design of the Voltage Dependent Current Order Limiter (VDCOL), the Current Regulate. and Timing Pulse generator. Supplementary control loops have also been introduced to result in a satisfactory performance as compared to that obtained one with the use of uncharacteristic harmonic filter on the AC side. All the options have been demonstrated through recovery performance of the DC link in response to both 1-phase and 3-phase 5 cycle faults on both rectifier and inverter commutating buses.

Study on the Grid-connected Photovoltaic Power System for Reducing Ripples of the PV Array Output (PV Array 출력리플 저감을 위한 계통연계형 태양광 인버터에 관한 연구)

  • Kim, H.J.;Chung, Y.H.;Lee, K.S.;Jon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1211-1212
    • /
    • 2007
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So, the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops; the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation and experiment. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

Diagnostic techniques of aging deterioration of power transformer by insulating paper (절연지에 의한 전력용변압기 열화진단 기술)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yoon, Yeo-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.449-452
    • /
    • 2004
  • The life of power transformer is basically dependent on the aging deterioration of insulating paper. Analysis of insulating paper for its DP value or tensile strength requires removal of a few strips of paper but direct measurement of this properties is not practical for in-service transformers. For this reason furfural analysis by HPLC has gained increasing favor as a means of estimating degradation of insulating papers in power transformers and this paper reports on the analysis of data on the concentration of furfural in oil samples from about 50 power transformers and the case study. The data showed that furfural content can estimate more accurately aging characteristics compared to concentration of CO, $CO_2$. We expect that these results can be useful to predict the aging characteristics and life diagnosis of power transformers and further the study must be continued.

  • PDF

Optimal location of FACTS controller for power flow (전력흐름 제어를 위한 FACTS 제어기의 위치 선정)

  • Park, Seong-Wook;Seo, Bo-Hyeok;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.16-18
    • /
    • 2004
  • The flexible AC transmissions system (FACTS) is the underpinning concept upon which are based promising means to avoid effectively power flow bottlenecks and ways to extend the loadability of existing power transmission networks. This paper proposes a method by which the optimal locations of the FACTS to be installed in power system under cost function. The optimal solution of this type of problem requires large scale nonlinear optimization techniques. We used Lagrange multipliers to solve a nonlinear equation with equality and ineaquality constraints. Case studies on the standard IEEE 14 bus system show that the method can be implemented successfully and that it is effective for determining the optimal location of the FACTS.

  • PDF

Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System (계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구)

  • Kim, Hee-Jung;Chung, Yong-Ho;Lee, Ki-Su;Jon, Young-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

An Analysis of Voltage Multiplier Circuits for Smart Phone RF Wireless Charging (스마트폰 RF 무선충전을 위한 전압 체배기 회로 분석)

  • Son, Myung Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.29-33
    • /
    • 2021
  • A 5.8-GHz 1W wireless power transmission system was used for charging a smart phone. The voltage of one RF power receiver with antenna was not enough for charging. Several power receivers for charging a smart phone was connected serially. The voltage of several RF power receivers are highly enough for charging a smart phone within 50cm. However, the lack of current from small capacitances of RF-DC converters is not suitable for charging smart phone. It means very long charging time. In this paper, the voltage multiplier circuits for RF-DC converters were analyzed to increase the current and voltage at the same time to reduce the charging time in smartphone RF wireless charging. Through the analysis of multiplier circuits, the 7-stage parallel multiplier circuit with voltage-doubler units are suitable for charging the smartphone, which supplies 5V and 700mA at 3V@5.8GHz.

Long-Term Maximum Power Demand Forecasting in Consideration of Dry Bulb Temperature (건구온파를 오인한 장기최대전력수요예측에 관한 연구)

  • 고희석;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.10
    • /
    • pp.389-398
    • /
    • 1985
  • Recently maximum power demand of our country has become to be under the great in fluence of electric cooling and air conditioning demand which are sensitive to weather conditions. This paper presents the technique and algorithm to forecast the long-term maximum power demand considering the characteristics of electric power and weather variable. By introducing a weather load model for forecasting long-term maximum power demand with the recent statistic data of power demand, annual maximum power demand is separated into two parts such as the base load component, affected little by weather, and the weather sensitive load component by means of multi-regression analysis method. And we derive the growth trend regression equations of above two components and their individual coefficients, the maximum power demand of each forecasting year can be forecasted with the sum of above two components. In this case we use the coincident dry bulb temperature as the weather variable at the occurence of one-day maximum power demand. As the growth trend regression equation we choose an exponential trend curve for the base load component, and real quadratic curve for the weather sensitive load component. The validity of the forecasting technique and algorithm proposed in this paper is proved by the case study for the present Korean power system.

  • PDF

Vulnerability Assessment of a Large Sized Power System Using Neural Network Considering Various Feature Extraction Methods

  • Haidar, Ahmed M. A;Mohamed, Azah;Hussian, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.167-176
    • /
    • 2008
  • Vulnerability assessment of power systems is important so as to determine their ability to continue to provide service in case of any unforeseen catastrophic contingency such as power system component failures, communication system failures, human operator error, and natural calamity. An approach towards the development of on-line power system vulnerability assessment is by means of using an artificial neural network(ANN), which is being used successfully in many areas of power systems because of its ability to handle the fusion of multiple sources of data and information. An important consideration when applying ANN in power system vulnerability assessment is the proper selection and dimension reduction of training features. This paper aims to investigate the effect of using various feature extraction methods on the performance of ANN as well as to evaluate and compare the efficiency of the proposed feature extraction method named as neural network weight extraction. For assessing vulnerability of power systems, a vulnerability index based on power system loss is used and considered as the ANN output. To illustrate the effectiveness of ANN considering various feature extraction methods for vulnerability assessment on a large sized power system, it is verified on the IEEE 300-bus test system.

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

Study on the energy savings in the mobile communication repeater using a power factor correction circuit (역률보상회로를 이용한 이동통신 중계기의 에너지 절감에 관한 연구)

  • Lim, Byoung-Chul;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1854-1860
    • /
    • 2014
  • In this paper, the energy saving on mobile communication repeater is studied. DB(Dual Band) small repeater, which is currently used in the field for indoor coverage, is adopted as a test unit. For reducing the power consumption, PFC (Power Factor Correction) is included on SMPS (Switching Mode Power Supply) of the DB small repeater. The test results show that approximately 38.9% of the power consumption is reduced comparing with the repeater without PFC. It means that approximately 230.43kWh per unit can be saved annually.