• 제목/요약/키워드: power flow

Search Result 6,156, Processing Time 0.036 seconds

Highly Efficient High-Voltage MOSFET Converter with Bidirectional Power Flow Legs

  • Ryu, Hyung-Min
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.265-270
    • /
    • 2014
  • In terms of power loss, a MOSFET has two advantages over an IGBT with an antiparallel diode: purely resistive without an offset voltage in conduction and no tail current at turn-off. However, the reverse recovery characteristic of the body diode is so poor that MOSFETs have not yet been available for high-voltage power converters with bidirectional power flow legs. This paper introduces how MOSFETs can be fully applied to high-voltage power converters with bidirectional power flow legs in order to achieve high efficiency. With a bidirectional DC-DC converter with one leg as the simplest example, the basic circuit topology and operating principle are described in detail. The high efficiency and stable operation of the proposed converter are validated through experiments with a 1.5 kW prototype.

A Study on Power Flow Analysis of DC Traction Power Supply System with PWM Rectifier (PWM 정류기를 적용한 직류급전시스템의 조류계산에 대한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1919-1924
    • /
    • 2016
  • In general, Diode rectifier has been applied to DC traction power supply system. Diode has some characteristics which is voltage drop in inverse proportion of load because of non-controlled switch, and cannot flow a current in reverse bias. So, voltage drop occurs frequently, and regenerated power cannot use in substation. The PWM rectifier is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper proposes analysis algorithm for DC traction power supply system with PWM rectifier.

An Algorithm for BITC Evaluation considering the Power Control Characteristics of FACTS Devices (FACTS기기의 유효전력 제어특성을 고려한 모선간 송전용량 평가 알고리즘)

  • Yoon, Yong-Beum;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.113-118
    • /
    • 1999
  • In this, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS devices is presented. The real power flow setting of the FACTS devices is adjusted so that it transfers the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS devices can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

The Optimal Pourer Flow Considering the Characteristics of Electric Pourer Consumers (전력소비자 특성을 고려한 최적조류계산)

  • 김문영;백영식;송경빈
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.107-113
    • /
    • 2003
  • In a deregulated electric power market, a demand function to consider the characteristics of electric power consumers should be required. It is essential that the optimal power flow algorithm with object function of social welfare maximization using the demand function for a competitive electric power market is applied to resolve in a point of economic benefits as well as the security of power systems. Therefore, in this paper, we implement the optimization problem based on linear programming to consider the characteristics of electric power consumers using the demand function and analyze not only the nodal cost for generations and demands but also the variation of demands as a function of the characteristics of electric power consumers through numerical studies.

Development of Optimal Power Flow for the Ancillary Service of Reactive Power Generation under Restructuring Environment (전력산업 구조개편 환경 하에서 무효전력 보조서비스 운용을 위한 최적조류계산법 개발)

  • Lee, Seung-Ryeol;Lee, Byeong-Jun;Song, Tae-Yong;Jeong, Min-Hwa;Mun, Yeong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.37-44
    • /
    • 2002
  • This Paper suggests reasonable pricing mathod fur Reactive Power in Optimal Power Flow for the system analysis. Under restructuring, not only real power pricing but also reactive power pricing is important for the system analysis and operation. If people just focus on real power pricing, the Generators may no generate reactive power voluntarily, because the Generators may not recover the cost of the reactive power generation. So making a reasonable reactive power pricing is becoming more important than any other time. In this paper, the authors set a Proper Power factor and price the portion of the reactive power that exceeds the power factor using Interior Point Method. By applying this method, the System operator can use this strategy for the analysis of reactive power generation pricing and the Generator can get the motivation to generate reactive power. The author develops fully optimized fast Primal Dual Interior Point Method with sparsity technique and applies this method to Reliability Test System (RTS24) and KEPCO 674 bus system (684 buses. 1279 lines). It shows adaptability and usefulness.

Computational Flow Analysis on the Flow Field Improvement of an Indoor RAC by LES (LES에 의한 RAC 실내기의 유동장 개선에 관한 전산유동해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.29-36
    • /
    • 2012
  • The computational flow analysis using LES technique was introduced to investigate the flow field improvement of an indoor RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. This unsteady three-dimensional numerical analysis was carried out by the commercial SC/Tetra software. The edge blocks were adopted in this study as a tool for the flow field improvement of an indoor RAC. In view of the results so far achieved, the edge blocks cause the center of an eccentric vortex to be stable along all length of a cross-flow fan, and then, the static pressure and the velocity vector show a stable distributions. In consequence, because the edge blocks eliminate a reverse flow near the edges, an exhausting flow becomes to be stable and uniform.

A Fully-implicit Velocity Pressure coupling Algorithm-IDEAL and Its Applications

  • SUN, Dong-Liang;QU, Zhi-Guo;He, Ya-Ling;Tao, Wen-Quan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.1-13
    • /
    • 2008
  • An efficient segregated algorithm for the coupling of velocity and pressure of incompressible fluid flow, called IDEAL Inner Doubly-Iterative Efficient Algorithm for Linked-Equations), has been proposed by the present authors. In the algorithm there exist double inner iterative processes for pressure equation at each iteration level, which almost completely overcome two approximations in SIMPLE algorithm. Thus the coupling between velocity and pressure is fully guaranteed, greatly enhancing the convergence rate and stability of solution process. The performance of the IDEAL algorithm for three-dimensional incompressible fluid flow and heat transfer problems is analyzed and a systemic comparison is made between the algorithm and three other most widely-used algorithms (SIMPLER, SIMPLEC and PISO). It is found that the IDEAL algorithm is the most robust and the most efficient one among the four algorithms compared. This new algorithm is used for the velocity prediction of a new interface capturing method. VOSET, also proposed by the present author. It is found that the combination of VOSET and IDEAL can appreciably enhance both the interface capture accuracy and convergence rate of computations.

  • PDF

A Fully-implicit Velocity Pressure coupling Algorithm-IDEAL and Its Applications

  • Sun, Dong-Liang;Qu, Zhi-Guo;He, Ya-Ling;Tao, Wen-Quan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1-13
    • /
    • 2008
  • An efficient segregated algorithm for the coupling of velocity and pressure of incompressible fluid flow, called IDEAL (Inner Doubly-Iterative Efficient Algorithm for Linked-Equations), has been proposed by the present authors. In the algorithm there exist double inner iterative processes for pressure equation at each iteration level, which almost completely overcome two approximations in SIMPLE algorithm. Thus the coupling between velocity and pressure is fully guaranteed, greatly enhancing the convergence rate and stability of solution process. The performance of the IDEAL algorithm for three-dimensional incompressible fluid flow and heat transfer problems is analyzed and a systemic comparison is made between the algorithm and three other most widely-used algorithms (SIMPLER, SIMPLEC and PISO). It is found that the IDEAL algorithm is the most robust and the most efficient one among the four algorithms compared. This new algorithm is used for the velocity prediction of a new interface capturing method -VOSET, also proposed by the present author. It is found that the combination of VOSET and IDEAL can appreciably enhance both the interface capture accuracy and convergence rate of computations.

  • PDF

A Comparative Study on the Bus Voltage Control Effect of STATCOM and UPFC in Power Flow Analysis of Power Systems (전력계통의 조류해석에서 STATCOM과 UPFC의 모선전압 제어효과에 대한 비교연구)

  • 김덕영;국경수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an comparative study on the effect of STATCOM and UPFC to power flow analysis of power systems. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for power flow analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

A Method to Determine the Droop Constant of DGs Considering the Configuration and Active Power Control Mode (분산전원의 구성 및 출력 제어 방법에 따른 Droop 계수 설정 방법)

  • Ahn, Seon-Ju;Park, Jin-Woo;Chung, Il-Yop;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1954-1961
    • /
    • 2008
  • Microgrid usually consists of a cluster of distributed generators(DGs), energy storage systems and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents detailed descriptions of two different options for controlling the active power of DGs in the microgrid. One is regulating the power injected by the unit to a desired amount(Unit output power control) and the other is to regulate the flow of active power in the feeder where the unit is installed to a constant(Feeder flow control). Frequency-droop characteristics are used to achieve good active power sharing when the microgrid operates in the islanded mode. The change in the frequency and the active power output of DGs are investigated according to the control mode and the configuration of DGs when the microgrid is disconnected from the main grid. From the analysis, this paper proposes a method to determine the droop constant of DGs operating in the feeder flow control mode. Simulation results using the PSCAD/EMTDC are presented to validate the approach, which shows good performance as opposed to the conventional one.