• Title/Summary/Keyword: power distribution line

Search Result 812, Processing Time 0.029 seconds

Electromagnetic Field Distribution of Reactors for Matrix-type SFCLs under Triple Lines-to-Ground Faults (삼선 지락사고 발생시 매트릭스형 한류기용 리액터의 전자장 분포 해석)

  • Chung, Dong-Chul;Han, Tae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.459-463
    • /
    • 2011
  • In this paper we reported the characteristics of 1 line, 2 lines and 3 lines-to-ground fault of matrix-type SFCLs (MFCLs) and the electromagnetic field distribution of reactors for MFCLs under the same cases of ground faults. To do this, we fabricated MFCLs with 6 reactors for 3 phases. Each reactor had the length of 270 mm and diameter of 80 mm. 6 reactors were made by Bakelite. We reported experimental results, including fault currents, fault voltages and magnetic field distribution according to phase differences between each phase. We confirmed that experimental results will be useful in next future plan for real power grid.

Emergency Service Restoration Algorithm Considering Service Rank in Distribution System (서비스우선순위를 고려한 긴급정전복구 앨고리즘)

  • Song, Kil-Yeong;So, Min-He;Jeong, Min-Hwa;NamKung, Jae-yong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.800-803
    • /
    • 1996
  • This paper proposes the algorithm to solve emergency service restoration problems using efficient reconfiguration method in distribution system. In this algorithm, we try to avoid the blackout of important loads by considering service rank. It is possible to reconfigurate the system by using fuzzy inference results in which was reflected the expected distribution power, line capacity and service rank. A 27-bus, 32-branch model system is used to demonstrate the effectiveness of the proposed algorithm.

  • PDF

A Novel Droop Control Method to Minimize Distribution Loss in DC Microgrid (DC 마이크로그리드의 배전 손실 최소화를 위한 새로운 드룹 제어 기법)

  • Kim, Seok-Woong;Choi, See-Young;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.371-372
    • /
    • 2015
  • Dc microgrid has the advantage of high efficiency as compared to the ac system. Droop method has been realized to suppress the current mismatching among the distributed sources. However, this method involves distribution loss due to the line impedance. In this paper, a novel droop method is proposed to minimize the distribution loss as well as the voltage deviation by adjusting the droop coefficient. The proposed droop method is verified by using the simulation based on PSCAD/EMTDC.

  • PDF

Analysis of Salt Contamination on the Location and the Distance from the coastline (지역 및 해안거리에 따른 염분오손 분석에 관한 연구)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam;Ko, Dong-Hyeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.511-512
    • /
    • 2006
  • The salt contamination on the distribution facilities is one of the major concern areas because more than 90% of salt contaminated failure occurs in distribution facilities. The periodic measurement of the Equivalent Salt Deposit Density(ESDD) is essential to manage and operate the power line. The ESDD has taken from the 112 position which is located on the coastline of the Korean Peninsula. The ESDD will be presented with the location and the distance from the coastline.

  • PDF

Communication Methodology Between Digital FRTUs Based on Wi-Fi Communication for the Smart Grid of Distribution System Area (스마트 그리드 배전 시스템을 위한 와이파이 통신에 기반한 디지털 FRTU간 통신 방법론 기초연구)

  • Woo-Kyung, Jin;Ji-Hyeon, Youn;Min-Seok, Choi;Jae-Hyun, Lee;Birek, Ohgan;Yun-Seok, Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1113-1120
    • /
    • 2022
  • In this paper, a communication methodology for the digital FRTU(: Feeder Remote Terminal Unit) required by the smart grid distribution system was studied. The digital FRTU consists of a fault handling unit and a communication unit. The fault handling unit transmits fault information to the communication unit in case of a failure, and the communication unit is designed to autonomously determine the fault section through two-way communication between surrounding digital FRTUs. For performance verification, a performance verification system consisting of 3 line sections based on 3 digital FRTUs was constructed to enable fault simulation for various failure scenarios. Various fault cases including one phase ground fault, line-to-line short-circuit fault, and three-phase short-circuit fault were experimentally simulated on the established performance verification system, and the validity of the developed methodology was confirmed by proving the accurate fault section inference results for each fault simulation case.

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.

A Study on the Analysis of Solar Consumer Perception Using Big Data

  • Seungwon Lee
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.1
    • /
    • pp.254-261
    • /
    • 2024
  • Among eco-friendly energy, solar energy is one of the renewable energy sources that is developing in the spotlight in many countries. In line with this, the Korean government and local governments are carrying out projects to provide subsidies for the distribution of household solar power, raising the spread of household solar power and awareness. However, due to the lack of research on consumer perception of household solar power, this study investigated the perception of household solar power from 2015 to 2022 by setting the central word as solar power. As a result, 2016 had the highest number of collections, and when the top 50 words for each year were analyzed, it was confirmed that words related to the installation and maintenance of household solar power dominated. And through CONCOR analysis, a total of four were derived: solar energy recognition, renewable and eco-friendly energy recognition, solar government policies, solar companies, and perceptions of households. Through emotional analysis, it was confirmed that 2021 had the most positive data. As a result, consumer perception of household solar power is positive based on what was mentioned above, but research on how to use negative opinions on waste control and installation and maintenance should be conducted.

An Application of advanced Dijkstra algorithm and Fuzzy rule to search a restoration topology in Distribution Systems (배전계통 사고복구 구성탐색을 위한 개선된 다익스트라 알고리즘과 퍼지규칙의 적용)

  • Kim, Hoon;Jeon, Young-Jae;Kim, Jae-Chul;Choi, Do-Hyuk;Chung, Yong-Chul;Choo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.537-540
    • /
    • 2000
  • The Distribution System consist of many tie-line switches and sectionalizing switches, operated a radial type. When an outage occurs in Distribution System, outage areas are isolated by system switches, has to restored as soon as possible. At this time, system operator have to get a information about network topology for service restoration of outage areas. Therefore, the searching result of restorative topology has to fast computation time and reliable result topology for to restore a electric service to outage areas, equal to optimal switching operation problem. So, the problem can be defined as combinatorial optimization problem. The service restoration problem is so important problem which have outage area minimization, outage loss minimization. Many researcher is applying to the service restoration problem with various techniques. In this paper, advanced Dijkstra algorithm is applied to searching a restoration topology, is so efficient to searching a shortest path in graph type network. Additionally, fuzzy rules and operator are applied to overcome a fuzziness of correlation with input data. The present technique has superior results which are fast computation time and searching results than previous researches, demonstrated by example distribution model system which has 3 feeders, 26 buses. For a application capability to real distribution system, additionally demonstrated by real distribution system of KEPCO(Korea Electric Power Corporation) which has 8 feeders and 140 buses.

  • PDF

Outage restoration in electric distribution system using Dijkstra algorithm (Dijkstra 알고리즘을 이용한 배전계통에서의 사고복구)

  • Kim, Hoon;Jeon, Young-Jae;Lee, Seung-Yun;Kim, Jae-Sung;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1416-1418
    • /
    • 1999
  • This paper presents a restoration method by using Dijkstra algorithm for outage restoration problems in distribution system that considering load capacity constraints and operation constraints. Restoration problem in distribution system is difficult to solve problem in a short times, because of a distribution system that supplies power for customers combined with many tie-line switches and sectionalizing switches and have to satisfy plenty of operation conditions. Therefore, this paper applied Dijkstra algorithm which is satisfy radial operation conditions in distribution system. This proposed method used Kruskal algorithm include to Dijkstra algorithm Therefore, proposed method is restored to a outage sections in a short times and just then to satisfied with a operation conditions in distribution system. A 26-bus, 31-branch model system is used to demonstrate the effectiveness of the proposed method.

  • PDF

Neural Network Modeling of Memory Effects in RF Power Amplifier Using Two-tone Input Signals (Two-Tone 입력을 이용한 RF 전력증폭기 메모리 특성의 신경망 모델링)

  • Hwangbo Hoon;Kim Won-Ho;Nah Wansoo;Kim Byung-Sung;Park Cheonsuk;Yang Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1010-1019
    • /
    • 2005
  • In this paper, we used neural network technique to model memory effects of RF power amplifier which is fed by two-tone input signals. The memory effects in power amplifier were identified by observing the unsymmetrical distribution of IMD(Inter-Modulation Distortion) measurements with the change of tone spacings and power levels. Different asymmetries of IMD were also found at different center frequencies. We applied TDNN technique to model LDMOS power amplifier based on two tone IMD data, and the accuracy was very high compared to other modeling methods such as the(memoryless) adaptive modeling method.