• Title/Summary/Keyword: power distribution line

Search Result 812, Processing Time 0.028 seconds

Analysis on the Power Spectrum of Electromagnetic Waves Radiating from the Distributorless Spark Ignition System (무배전기식 불꽃 점화 시스템에서 복사되는 전자파의 전력 스펙트럼 분석)

  • Choe, Gwang-Je;Jho, Shi-Gie;Jeung, Weol-Rark;Jang, Sung-Kuk;Kang, Shin-Han
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.45-51
    • /
    • 2008
  • This paper presents theoretical and experimental analysis on the characteristics of the power spectrum of electormagnetic waves radiating from the spark plug and their cables of a distributorless ignition system. The theoretical study was conducted applying the microwave transmission line theory and the antenna theory. The experimental works were carried out to measure the standing wave ratio(SWR) and the radiation power spectrum of this system. As a result, it has been found that a spark plug and its cable is working as a monopole antenna radiating elelctromagnetic waves. Because of its similar structure to a monopole antenna, the envelope of radiation power spectrum distribution has a bell shape which can be obtained from a monopole antenna operating as a series resonant circuit. The frequency characteristics from the SWR measurements show a similar frequency characteristics of power spectrum of the system studied. Also, it has been found that the density of the power spectrum of the system fitting a long time used spark plug is higher than that of fitting a new spark plug.

Development of a New Personal Magnetic Field Exposure Estimation Method for Use in Epidemiological EMF Surveys among Children under 17 Years of Age

  • Yang, Kwang-Ho;Ju, Mun-No;Myung, Sung-Ho;Shin, Koo-Yong;Hwang, Gi-Hyun;Park, June-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.376-383
    • /
    • 2012
  • A number of scientific researches are currently being conducted on the potential health hazards of power frequency electric and magnetic field (EMF). There exists a non-objective and psychological belief that they are harmful, although no scientific and objective proof of such exists. This possible health risk from ELF magnetic field (MF) exposure, especially for children under 17 years of age, is currently one of Korea's most highly contested social issues. Therefore, to assess the magnetic field exposure levels of those children in their general living environments, the personal MF exposure levels of 436 subjects were measured for about 6 years using government funding. Using the measured database, estimation formulas were developed to predict personal MF exposure levels. These formulas can serve as valuable tools in estimating 24-hour personal MF exposure levels without directly measuring the exposure. Three types of estimation formulas were developed by applying evolutionary computation methods such as genetic algorithm (GA) and genetic programming (GP). After tuning the database, the final three formulas with the smallest estimation error were selected, where the target estimation error was approximately 0.03 ${\mu}T$. The seven parameters of each of these three formulas are gender (G), age (A), house type (H), house size (HS), distance between the subject's residence and a power line (RD), power line voltage class (KV), and the usage conditions of electric appliances (RULE).

A Study on Development of a New Algorithm to Solve Load Flow for Distribution Systems (배전계통조류계산을 위한 새로운 알고리즘에 관한 연구)

  • Moon, Young-Hyun;Yoo, Sung-Young;Choi, Byoung-Kon;Ha, Bock-Nam;Lee, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.918-922
    • /
    • 1998
  • With the development of industry, the qualitical advancement of power is needed. Since it is placed in the end step of power system, the fault at the distribution system causes some users blackout directly. So if the fault occurs, quick restoration is very important subject and, for the reason, induction of the distribution automation system is now being progressed briskly. For the quick restoration of the faulted distribution system, the load shedding of the blackout-area must be followed, and the other problems like the shedded load, faulted voltage and the rest may cause other accident. Accordingly load shedding must be based on the precise calculation technique during the distribution system load flow(dist flow) calculation. In these days because of its superior convergence characteristic the Newton-Raphson method is most widely used. The number of buses in the distribution system amounts to thousands, and if the fault occurs at the distribution system, the speed for the dist flow calculation is to be improved to apply to the On-Line system. However, Newton-Raphson method takes much time relatively because it must calculate the Jacobian matrix and inverse matrix at every iteration, and in the case of huge load, the equation is hard to converge. In this thesis. matrix equation is used to make algebraical expression and then to solve load flow equation and to modify above defects. Then the complex matrix is divided into real part and imaginary part to keep sparcity. As a result time needed for calculation diminished. Application of mentioned algorithm to 302 bus, 700 bus, 1004 bus system led to almost identical result got by Newton-Raphson method and showed constant convergence characteristic. The effect of time reduction showed 88.2%, 86.4%, 85.1% at each case of 302 bus, 700 bus system 86.4%, and 1004 bus system.

  • PDF

A Study on Decision Plan of Hosting Capacity for Distribution Feeder (배전선로 연계용량 선정방안에 관한 연구)

  • Kim, Seong-Man;Oh, Joon-Seok;Kim, Ok-Hee;Lim, Hyeon-Ok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.653-660
    • /
    • 2021
  • Renewable energy resources are rapidly becoming an integral part of electricity generation portfolios around the world due to declining costs, government subsidies, and corporate sustainability goal. Interacting wind, solar, and load forecast errors can create significant unpredictable impacts on the distribution system, feeder congestion, voltage standard and reactive power stability margins. These impacts will be increasing with the increasing penetration levels of variable renewable generation in the power systems. There is a limit to the maximum amount of renewable energy sources that can be connected in a distribution feeder by the connection rule of transmission & distribution facility in Korea. This study represents the decision plans of hosting capacity for distribution feeders without the need for significant upgrades to the existing transmission infrastructure. Especially, the paper suggests and discusses the hosting capacity standard of feeder cables and minimum load calculation of distribution feeders.

Size Characterization of Sodium Hyaluronate by Field Programming Frit Inlet Asymmetrical Flow Field-Flow Fractionation/Multiangle Light Scattering

  • Kim, Hoon-joo;Lee, Hee-jeong;Moon, Myeong-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.413-418
    • /
    • 2006
  • Sodium hyaluronate (NaHA), water soluble polymer having ultra-high molecular weight, is characterized by using on-line frit inlet asymmetrical flow field-flow fractionation (FI-AFlFFF) and multiangle light scattering (MALS). This study demonstrates the capability of power programming FI-AFlFFF for the separation of NaHA and the applicability of FI-AFlFFF with MALS for the characterization of molecular weight distribution and their structural information. Since sample injection and relaxation in FI-AFlFFF are achieved by using hydrodynamic relaxation, separation of high molecular weight polymers can be achieved smoothly without halting the separation flow. Experiments are carried out with the two different NaHA products (a raw NaHA sample and a thermally degraded NaHA product) and molecular weight distribution and conformations in solution are determined. Influence of sample filtration on the change of molecular weight distribution is also discussed.

Design of a Remote Automatic Earth Tester at Electric Pole in a Distribution Line (배전선로 변대주 원격자동 접지측정장치 설계)

  • Yoon, Gi-Gab;Yoon, Suk-Mu;Lee, Seung-Hak;Kim, Hong-Pil;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.498-500
    • /
    • 2000
  • Generally, the earth resistance of distribution lines are measured under the condition of the climbing pole. This paper proposed the design technique of a new concept type remotoe automatic measuring system without climbing electric distribution poles. The worker on the earth under pole, can measure by using the CT on the located at the top of COS operating Stick. The system is useful for safety of worker, and saving mans, times for measuring.

  • PDF

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

Analysis of effects of OCR in operation mode during fault ocuurs in Distribution System (배전계통 내 고장발생시 운전모드가 과전류계전기에 미치는 영향 분석)

  • Kim, Yong-Hwan;Rhee, Sang-Bong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.563-564
    • /
    • 2015
  • Recently, distributed generation using renewable energy resources have increased due to the limitation of conventional energy. To utilize these energy source effectively, a method of applying the energy storage system(ESS) in distribution system has been considered. In this paper, we simulated the one line-to-ground fault in power system with ESS. Based on these simulations, we analyzed the effect on Over Current Relay(OCR) operation. As a result, ESS operation modes result fault current fluctuation. Thus, OCR need to reset the pick up current. This paper analyze effect of ESS in distribution system according to OCR setting by using ElectroMagnetic Transient Program(EMTP).

  • PDF

고진공에서 이온 카운터를 사용한 실시간 입자 모니터링 시스템의 개발

  • An Gang-Ho;Kim Yong-Min;Yun Jin-Uk;Gwon Yong-Taek
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.255-258
    • /
    • 2006
  • In this paper, the new method which is monitoring quantity of particles using by ion-counter has been developed. ISPM system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. Ion-counter applied positive voltage could detect only positive charged particles. Therefore charged particles to Boltzmann equilibrium distribution or to some identified charge distribution can be detected by ion-counter. Ion-counter could install on the exhaust line of process equipment since pressure loss is structurally low. ISPM system has been certified by comparison with the result of SMPS (Scanning Mobility Particle Sizer) system. The relation coefficiency is above 0.98 about $20{\sim}300nm$ particles with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

Optimal Routing of Distribution Networks Considering Reliability Indices (신뢰도지수를 고려한 배전계통시스템의 최적전력전송경로 결정)

  • Roh, P.K.;Kim, J.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.915-917
    • /
    • 1998
  • Optimal routing of distribution networks can be attained by keeping the line power capacity limit to handle load requirements, acceptable voltage at customer loads, and the reliability indices such as SAIFI, SAIDI, CAIDI, and ASAI limits. This method is composed of optimal loss reduction and optimal reliability cost reduction. The former is solved relating to the conductor resistance of all alternative routes, and the latter is solved relating to the failure rate and duration of each alternative route. The routing considering optimal loss only and both optimal loss and optimal reliability cost are compared in this paper. The results showed that reliability cost should be considered as well as loss reduction to achieve the optimal routing in the distribution networks.

  • PDF