• Title/Summary/Keyword: power consumption analysis

Search Result 1,194, Processing Time 0.029 seconds

Performance Analysis of Cooperative Diversity on the Usage of Opportunistic Relay (기회주의적인 중계기 사용에 대한 협력 다이버시티의 성능 분석)

  • Kim, Tae-Wook;Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.7-12
    • /
    • 2014
  • The data forwarding transmission is an important function of the relay in cooperative communication in wireless communication systems. However, additional relay cause the waste of power consumption and cost. Therefore, in this paper, we consider how to use the user mobile devices in stead of relays to deal with this problem. In this paper, we proposed the protocol that divide each relay into two states of idle and non-idle. The receiver has two functions of base station and user mobile device. In this case, it is possible that no additional cost, and improve the spectral efficiency and network capacity. We verified BER performance for the proposed protocol over Rayleigh fading through Monte-Carlo simulation.

Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House (저에너지주택의 지열히트펌프시스템 냉·난방 성능분석)

  • Baek, Namchoon;Kim, Sungbum;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

A Study on the Heat Loss Reduction of a Refrigerator by Thermal Conductivity Change and Partial Removal of Rubber Magnet (냉장고 가스켓 주위 고무자석 재질 및 형상 변경에 따른 열손실 개선 연구)

  • Ha, Ji Soo;Ahn, Won Sul
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.240-246
    • /
    • 2014
  • The present study has been carried out to reduce the heat loss from a refrigerator by changing thermal conductivity and partial removal of rubber magnet near refirgerator gasket. To perform this purpose, two dimensional heat transfer analysis for the horizontal cross sectional plane of a refrigerator has been accomplished. From the present study, it could be seen that the heat loss could be reduced nearly 7% by changing thermal conductivity of rubber magnet from 10W/mK to 1W/mK. The heat loss reduction, 17%, could be achieved by removal of rubber magnet near hotline and the effect on the heat loss reduction by partial removal of rubber magnet might be helpful for the refrigerator power consumption.

Performance Analysis of 1-2-1 Cooperative Protocol in Wireless Sensor Networks (무선 센서 네트워크에서 1-2-1 협력 프로토콜에 관한 연구)

  • Choi, Dae-Kyu;Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.5
    • /
    • pp.113-119
    • /
    • 2008
  • Conventional 1-1-1 cooperative protocol offers path-loss gain as advantage of multi-hop and spatial diversity which is equivalent to MIMO system. This protocol is enable to get higher reliability and reduction of power consumption than those of the single-hop or multi-hop. But the 1-1-1 cooperative protocol get only the diversity order 2 and limited path-loss reduction gain because this protocol has a single cooperative relay. We propose 1-2-1 cooperative protocol using two cooperative relays R1, R2. The 1-2-1 cooperative protocol can improve path-loss reduction and increase diversity order 3. Moreover, the cooperative relay R2 attains diversity order 2. The signaling method in transmission uses DF (Decode and Forward) or DR (Decode and Reencode) and 1-2-1 DF/DR cooperative protocol are applied to clustering based wireless sensor networks (WSNs). Simulations are performed to evaluate the performance of the protocols under Rayleigh fading channel plus AWGN (Additive White Gaussian Noise).

  • PDF

Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide (이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석)

  • Huh, Cheol;Kang, Seong-Gil;Hong, Sup;Choi, Jong-Su;Baek, Jong-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

An input-buffer ATM switch based on the dynamic change of the threshold for the occupancy of the buffer (버퍼에 설정된 점유 임계치의 동적 변화에 기초한 입력버퍼형 ATM 스위치)

  • Paik, Jung-Hoon;Lim, Chae-Tak
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.19-27
    • /
    • 1999
  • This paper propose a contention resolution policy featuring dynamic change of the threshold for the occupancy of the input buffer for an input buffering ATM switching architecture and its hardware implementation strategy. The strategy is provided with the aim of the simple structure that achieves the reduction of the signal path and the power consumption. The threshold is changed dynamically every time slot based both the arrived of cells and the cell service resulting from the contention resolution. The performance on the cell loss of the proposed policy is performed and compared with the conventional policy under the diverse traffic conditions through both the analysis based ont the Markov chain and the simulation.

  • PDF

Analysis of Data Transfer Overhead Among Memory Regions in Java Program (자바 프로그램에서 메모리 영역 간 자료 이동에 따른 부담 분석)

  • Yang, Hee-Jae
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.5
    • /
    • pp.281-287
    • /
    • 2008
  • Data transfers occur during the execution time of a Java program, from constant to variable, from variable to other variable and so on. Data are located in memory and hence data transfer requires access to memory. As memory access generates both time delay and energy consumption it is absolutely necessary to know the data transfer overheads incurred among different paths not only to write an efficient program but also to build a high-performance Java virtual machine. In this paper we classify Java memory into three different regions, constant, local variable, and field, and then investigate data transfer overheads among these regions. The result says that the transfer between local variables incur the least overhead usually, while the transfer between fields incur the most. The difference of overheads reaches up to a double. Optimization techniques like JIT reduces the data transfer overhead dramatically. It is observed that the overhead is reduced from 14 to 27 times for the case of Hotspot JVM.

Initial Climb Mission Analysis of a Solar HALE UAV (태양광 고고도 장기체공 무인기의 초기 상승 임무 분석)

  • Shin, Kyo-Sic;Hwang, Ho-Yon;Ahn, Jon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.6
    • /
    • pp.468-477
    • /
    • 2014
  • In this research, how a solar powered HALE (high altitude long endurance) UAV (Unmanned Aerial Vehicle) can climb and reach mission altitude, 18km, starting from the ground using only solar energy. A glider type aircraft was assumed as a baseline configuration which has wing area of $35.98m^2$ and aspect ratio of 25. Configuration parameters, lift and drag coefficients were calculated using OpenVSP and XFLR5 that are NASA open source programs, and climb flights were predicted through energy balance between available energy from solar power and energy necessary for a climb flight. Minimum time climb flight was obtained by minimizing flight velocities at each altitude and total time and total energy consumption to reach the mission altitude were predicted for different take off time. Also, aircraft moving distances due to westerly wind and flight speed were calculated.

LED application VLC information network system configuration research (LED를 응용한 VLC 정보 네트워크 시스템 구성 연구)

  • lee, Jun-myung;Jang, Tae-su;Kang, Hyng-kil;Kim, Yong-Kab
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.13-14
    • /
    • 2012
  • Than fluorescent lamps or light bulbs, long life, small power consumption and to the development of modern technology, LED (Light Emitting Diode) devices have the advantage of easy control. For these reasons, using the LED device, lighting has been widely used. LED using optical fiber technology using LED lighting technology with the development of wireless communication technology is attracting attention again. Using LED lights this study analyzed the performance of the technology transfer and implementation of the information transmission system of the visible light communication using LED lighting of the White Visible Light Communication (VLC) based PC module transmitter and receiver modules. Has made a system that can transmit information more than the value of the initial distance ~ 50cm, depending on the presence or absence of the lens, in order to increase the efficiency of the LED modules with different efficiencies that could confirm the performance of the implementation of the research, analysis, and application methods. and about the possibility that you want to check.

  • PDF

Development of a Cycle Simulation Program for Multi-Airconditioning Systems using R410A (R410A를 사용하는 멀티에어컨 시스템을 위한 사이클 시뮬레이션 프로그램 개발)

  • Kim, Young-Jae;Park, In-Sub;Kim, Hak-Hee;Yoon, Baek;Gil, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.210-215
    • /
    • 2002
  • In this study, the computer program called Multi_Cycle, which simulates the steady-state performance (coefficient of performance, capacity, power consumption and etc.) of multi- airconditioning systems using R410A, was developed. In order to validate the simulation program, a series of case studies were carried out. The Multi_Cycle consists of several subroutines for simulating indoor units. outdoor unit, compressor, and expansion devices. and for estimating the thermodynamic and transport properties of the refrigerants and moist air. It would appear to be advantageous to use the Multi_Cycle for a performance analysis when considering various kinds of refrigerants and the complex operating conditions of each unit making up the multi-airconditioner cycle. Moreover, the Multi_Cycle would seem to be useful tool in optimizing a multi-airconditioning system and establishing economical and efficient operating conditions in the multi-airconditioner cycle. In the present study, the Multi_Cycle was programmed with Digital Visual Fortran for the main simulation code and Visual Basic for- the graphic user interface.

  • PDF