• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.023 seconds

Heat Transfer Enhancement using Nano Particles coated Surface (나노 코팅을 이용한 열전달 향상에 대한 연구)

  • Gang, Myung-Bo;KIm, Woo-Joong;Kim, Nam-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.2
    • /
    • pp.8-14
    • /
    • 2018
  • A boiling heat transfer is used in various industry such as power generation systems, heat exchangers, air-conditioning and refrigerations. In the boiling heat transfer system, the critical heat flux (CHF) is the important factor, and it indicated safety of the system. It has kept up studies on the CHF enhancement. Recently, it is reported the CHF enhancement, when working fluid used the nanofluid with excellent thermal properties. Therefore, in this study, we investigated the influence of nano particles coated surface for heat transfer enhancement in pure water, oxidized multi-wall carbon nanotube nanofluid (OMWCNT), and oxidized graphene nanofluid (OGraphene). Nanoparticles were coated for 120 sec on the surface, and we measured the CHF at the flow velocities of 0.5, 1.0, and 1.5 m/sec, respectively. As the results, both of the OMWCNT and OGraphene nanofluids increased up to about 34.0 and 40.0%.

A Study on the Flow Characteristics of Sirocco fan (씨로코팬의 유동특성에 관한 연구)

  • Lee, Duck-Gu;Kim, Geon-Il;Jung, Han-Byul;Sul, Jael-Lim;Lee, Heang-Nam;Park, Gil-Moon
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.200-204
    • /
    • 2005
  • The sirocco fan is used to get low noise, and it has been applied to a lot of industry field like the heat engine, the fluid instrument power plant, the food industry, environment industry etc... because there are not any problem even it is mixed with a any kind of liquid, gas, and solid. The flow characteristics in sirocco fan are investigated by PIV. The experiment using PIV measurement for Test section's flow characteristics acquired velocity distribution, .Condition : when sirocco fan in automobile air controller maximum 1450RPM, and a revolution is a variation (1)950RPM, (2)1100RPM, (3)1250RPM. The agreement a experiment shows the validity of this study and the results of this study would be useful to the engineers who design for the flow systems for heating, ventilation and air conditioning.

  • PDF

Performance Monitoring Results, Evaluation and Analysis of 50kW Grid-Connected PV System (50kW급 계통연계형 태양광발전시스템의 성능모니터링 결과 및 평가분석)

  • So, Jung-Hun;Yu, Byung-Gyu;Hwang, Hye-MI;Yu, Gwon-Jong;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.29-35
    • /
    • 2007
  • Monitoring system is constructed for evaluating and analyzing performance of installed 50kW grid-connected PV system and have been monitored since October 2005. As climatic and irradiation conditions have been varied through long-term operation, there is necessity for evaluating numerical values of PV(Photovoltaic) system performance to observe the overall effect of environmental conditions on their operation characteristics. This paper presents performance monitoring results and analysis on component perspective(PV array and power conditioning system) and global perspective(yield, losses) of PV system for one year monitoring periods.

The Development of a PCM Cold Storage Refrigerator using Forced Convection Method (강제대류방식 PCM 축냉장고 개발)

  • Lee, Sang-Ryoul;Ryu, In-Keun;Kim, Jin-Hong;Jun, Young-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.517-522
    • /
    • 2005
  • A cold storage refrigerator using phase change material(PCM) has been developed and its performance test results are provided here. The inner temperature of the refrigerator is controlled with forced convection driven by a fan using a DC battery. At the first, to freeze all the PCM of the ambient temperature by a built-in refrigerating machine, it took about 8 and 10 hours respectively at the refrigerator and the freezer mode. Then, without external power supply, the inner temperature of the cold storage refrigerator has been maintained at $-18{\pm}1^{\circ}C$ during 14 hours at the freezer mode and maintained at $3{\pm}^{\circ}C$ during 34 hours at the refrigerator mode. Just after the end of its valid usage as a refrigerator or a freezer, it took about 6 hours to refreeze the PCM for its reuse. During the test, the ambient temperature was kept at $30^{\circ}C$.

  • PDF

Study on the Operational Cost and Characteristics of a Hybrid Cooling Plant with a Ground Source Heat Pump (지열 열펌프가 적용된 복합냉방설비의 연계운전 특성 및 운전비용 분석)

  • Jeon, Jong-Ug;Jung, Hae-Won;Lee, Tae-Won;Kim, Yong-Ki;Hong, Dae-Hie;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.42-47
    • /
    • 2008
  • This paper reports the system performance of a hybrid plant, which combines a renewable energy plant of GSHP(Ground Source Heat Pump) with a conventional plant (screw water chiller). To find out operational cost and operating characteristics, the performance of the hybrid system was measured in a building located in Jeju island. Based on the measured data, the operating characteristics were analyzed and the operational cost was estimated by using payment table, which was provided by the Korea Electric Power Cooperation. Operating methods to save energy were recommended.

  • PDF

Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater (난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Yoon, Seok-Mann
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF

Experimental Study of Showcase Using Cold Storage System (축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF

Solar District Heating System (지역난방용 태양열시스템)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yoon, Eung-Sang;Yoon, Suk-Man;Sin, U-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

Heat Transfer of Array Impinging Jet on Concave Surfaces with Rectangular Fin (사각 핀이 설치된 오목충돌면에서 배열충돌제트의 국소 열전달 특성 고찰)

  • Oh, Sang-Hyun;Lee, Won-Hee;Lee, Dong-Hyun;Cho, Hyung-Hee;Kim, Mun-Young;Lee, Sung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1149-1154
    • /
    • 2008
  • The present study investigates the heat transfer characteristics on concave surface with array impinging jet and fin arrangement. The heat transfer coefficients was measured by TLC method. The Reynolds number based on jet hole diameter is 10,000 and hole diameter-to-plate distance ratio (H/d) is fixed at 2. The rectangular fins are installed in the curved channel and the width of fin varies from 1d to 3d. Without fins, the averaged heat transfer coefficients decreases as moves downstream region. While, the rectangular fins block the crossflow and higher heat transfer rates were observed compared to smooth channel.

  • PDF

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF