• Title/Summary/Keyword: power cable insulation

Search Result 244, Processing Time 0.026 seconds

Experimental Investigation of Composite Insulator for Insulation Design of HTS Cable (고온 초전도 케이블의 절연설계를 위한 복합절연물의 시험 연구)

  • Nguyen, Van Dung;Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Kwag, Dong-Sun;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.331-336
    • /
    • 2004
  • Due to the outstanding insulating characteristics, Laminated Polypropylene paper (LPP) and Kraft paper have been used as ac power insulation for conventional cable. Recently, both of LPP and Kraft has been studied as main insulation fur high temperature superconducting (HTS) cable. Ifowever, studies on the use of LPP/Kraft paper for HTS cables are thinly scattered. In this paper, the comparison among LPP, Kraft and LPP/Kraft Samples impregnated with liquid nitrogen $(LN_2)$ on dielectric insulation characteristics was investigated. It was found from the experimental data that the breakdown strength becomes lower in the order LPP, Lpp/Kraft and Kraft but the lifetime indices n becomes lower in the order Kraft, LPP/Kraft, LPP. Moreover, partial discharge inception and dielectric loss tangent become lower in the order Kraft, LPP, LPP/Kraft.

  • PDF

Analysis of Deterioration Characteristics by Filtering Processes at 6.6kV Power Cable Systems in Operation (운전 중인 6.6kV 전력 케이블 시스템의 필터링 과정에 의한 열화 특성 해석)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.205-211
    • /
    • 2014
  • With a development of modern industry, demand for electric power is rapidly increasing and the capacity of power transfer is required to become bigger and bigger. At power station, the high-voltage power cable is used as the only method in order to transfer electric power. In this paper, we have analyzed the deterioration characteristics of 6.6kV power cable systems in operation. For the time duration of 2000 days, we have measured the cable in operation in order to extract the data for the deterioration characteristics. By analyzing the data by means of several steps of filtering processes, we could obtain the linear relations of insulation resistances as a function of time. Furthermore, we can verify that the progress characteristics in deterioration process of 6.6kV power cable systems follows the process of heat deterioration.

A Study of Characteristic for Space Charge in CV Power Cable When Impressed DC and AC Voltage (직류 및 교류인가시 CV전력 케이블에 미치는 공간전하 특성 연구)

  • Jung, Young-Ill;Lim, Yong-Bae;Kim, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1960-1962
    • /
    • 2000
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction. insulation breakdown. dielectric character and so on. When apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA). It is analysis to take shape space charges under AC and DC voltage, clear up the point at issue for effect of DC withstand test.

  • PDF

A Study on the Heat Transfer Analysis based on Insulation Thickness Variation of Cable Splice Part (지중케이블 접속부의 절연층 두께변화에 따른 열해석 연구)

  • 최규식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.246-255
    • /
    • 1998
  • The cable cooling through installing the cooling pipe along the transmission cable becomes universal in foreign leading countries, especially in Japan, and, there are so many study results inside and outside of the country. However, the remarkable study result for cooling method of cable splice part is not achieved in spite of its importance. This paper is, therefore, carrys out detailed heat transfer analysis of existing 154kV underground cable-splice, depending on the insulation thickness variation when it is installed in manhole of tunnel whose temperature is maintained as $10^{\circ}C$ using refrigerator. This paper study also the cooling method of underground cable splice based on this result.

  • PDF

THE TREND OF DIAGNOSTIC METHODS FOR POWER CABLE (전력(電力)케이블 열화진단(劣化診斷) 기술(技術)의 동향(動向))

  • Hahn, K.M.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.779-783
    • /
    • 1992
  • In recent years, it is strongly required to supply high quality electrical power without insulation failure in distribution power cables. Therefore the exact measurement and judgment ar out deterioration degree of cables are essential to increase that supplying reliability. This paper will introduce various diagnostic methods of off-line and live-line cables also propose the judgement criteria and newly trend of diagnostic technique at present.

  • PDF

Design of 154kV, 1GVA HTS Cable (154kV, 1GVA 초전도케이블 설계)

  • Cho, Jeon-Wook;Sim, Ki-Duck;Kim, Seok-Ho;Lee, Su-Kil;Jang, Hyun-Man;Choi, Chang-Yeol;Lee, Kuen-Tae;Yang, Byeung-Mo;Kim, Seung-Rae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.192-192
    • /
    • 2010
  • DAPAS (Development of Advanced Power system by Applied Superconductivity technologies) program that the, superconductivity national program has been started one of the 21C frontier programs from 2001 in Korea. The 3rd phase of DAPAS program was started at April 2007, and the ultimate goal of HTS cable project is to develop 154kV, 1GVA class HTS cable. The structure of 154kV, 1GVA HTS cable is single core with cold dielectric insulation. The cable core consists of the former, conduction layer, electrical insulation layer, shielding layer. The cable cryostat consists of two corrugated seamless aluminum tubes as its high sealing reliability, the tubes separated through a spacer arrangement. Outdoor termination was developed by LS cable and cryogenic system by CVE for 154kV, 1GVA class HTS cable. The 154kV, 1GVA HTS cable will be installed and be tested in KEPCO Gochang Testing Center from June 2010.

  • PDF

Development of Pre-Mold Joints for High Voltage Cable System (I) (초고압 프리몰드형 접속함 개발 (I))

  • Lee, S.K.;Ko, E.K.;Kim, Y.H.;Baik, S.Y.;Kim, K.S.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1031-1033
    • /
    • 1999
  • The performance of cable joints for extra high voltage XLPE cable system is rapidly advancing combined with the development of insulation materials. The current trend of joints is in the direction of requiring less jointing techniques and installation time. This paper describes the performance of currently used joints regarding to their practical aspects and analyses design and manufacturing techniques for Pre-Mold Joint and Pre-fabricated Joint Box. Especially, basic tests and their results to obtain the design Parameter of PMJ are introduced.

  • PDF

Diagnostics of Power Cables using DC Voltage Decay method (직류전압감쇄법을 이용한 전력케이블의 절연열화진단)

  • Yi, Dong-Young;Kim, Sang-Joan;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1688-1691
    • /
    • 1997
  • In this work, we have developed the off-line diagnostic system for power cable insulation using DC voltage decay method to diagnose the insulation degradation of underground power cables. Measurement errors of diagnostic system are less than 1% for $1T{\Omega}$ internal resistor. We have also developed measurement and diagnostic programs for win95 which is suitable for the database construction and the management of data. We could conclude that it is possible to apply this system to the multi-grounded underground cable systems.

  • PDF

Characteristics of Radiated Electromagnetic Wave and Partial Discharge in Power XLPE Cable (전력용 XLPE Cable의 부분방전과 방사전자파 특성)

  • Lee, Kwang-Sik;Lee, Hyun-Chul;Park, Kwang-Seo;Yoon, Dae-Hee;Lee, Sang-Hun;Kim, Jong-Hwan;Kim, Chung-Nyun;Kim, Ki-Chai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.90-95
    • /
    • 2004
  • This paper simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. As one of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMI, EMC. From results of this study, It was confirmed that discharge Ogress were possible to be estimated by the proposed method.