180kV HVDC 해저케이블 기계적/전기적 특성 평가 (Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System)

  • 김남열;이태호;지봉기;이상진;김정년;전승익;윤희석;정수길;강채홍;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

부하 전류가 케이블의 수명에 미치는 영향에 대한 연구 (A study on the Effects of Load Current for Lifetime of Cable Systems)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권4호
    • /
    • pp.205-209
    • /
    • 2015
  • 발전소에서 설치 운영 중이 전력 케이블 시스템에서 사고가 발생함으로써 초래되는 경제적 손실은 매우 클 뿐만이 아니라, 원상 복구하는 데 많은 시간과 비용이 필요하다. 이를 대비하기 위하여 사고를 예측하고 방지하는 기술이 필요하다. 우리는 발전소에서 운전 중인 케이블의 절연 저항을 측정하기 위하여 부하 전류와 온도와의 상관 관계를 확인 하였고, 진단 데이터를 분석 평가함으로써 케이블 시스템의 열화 상태를 파악하여 사고가 발생하기 전에 케이블 교체를 할 수 시기를 예측하게 하였다. 이 논문에서 우리는 운전 중인 6.6 kV 케이블에서 부하 전류가 수명에 미치는 영향에 대하여 연구한 결과를 소개한다. 케이블의 부하에 전류가 흐르면, 도체에 열이 발생하게 되고 케이블의 수명이 감소된다. 케이블의 부하 전류가 수명에 미치는 영향을 파악하기 위하여 수명 이론을 적용함으로써 절연저항 및 전류 측정 장치를 개발하여 운전 중인 케이블에 설치하였다.

실리콘 처리에 의한 수트리 열화케이블의 절연회복 (Insulation rehabilitation of water tree aged cables by silicone treatment)

  • 김주용;송일근;한재홍;이동영;문재덕
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.14-21
    • /
    • 2000
  • 본 논문은 수트리 열화된 가교폴리에틸렌(XLPE) 절연 지중케이블의 절연회복을 위해 개발된 실리콘 처리 기법의 현장적용 가능성을 검토하기 위해 수트리 열화된 325 $\textrm{mm}^2$ CN/CV 케이블을 수거하여 실리콘 처리하고, 시간의 경과에 따른 절연성능 향상도를 분석한 것이다. 시료 케이블의 절연회복을 평가하기 위해 교류절연파괴시험을 실시했다. 또 실리콘 처리케이블의 평가를 위해 진단시험 및 케이블 특성평가를 수행했다. 실리콘 처리후 1년 경과 시료 케이블올 분석한 결과, 실리콘액(silicone fluid)과 수분이 효과적으로 결합해 절연파괴강도가 상당히 증가한 것으로 나타났다. 실험결과를 종합해 볼 때 수트리로 열화된 케이블의 절연성능 향상에 실리콘 처리가 효과적인 것으로 나타났다.

  • PDF

도체 수밀형 전력케이블의 가교잔사 가스에 의한 직선접속재 부풀음 현상 방지 대책 (The solution for preventing the expansion of cable joint caused by methane($CH_4$) gas to Water proof type of power cable)

  • 김종원;이기수;백흠수;최봉남;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2020-2022
    • /
    • 2000
  • The cross-linked polyethylene(herein after XLPE) insulated power cable emit the methane($CH_4$)gas in the course of chemical cross-linking process. The general stranded conductor easily discharge this methane gas through the gap of each stranded wires. But the special stranded conductor that filled with semi-conducting rubber compound to prevent water penetration which is applied to water proof type of cable(22.9kV CN/CV-W), disturb the methane gas emission. The pre-mold type cable joint shall be expanded gradually by emit of gas left in XLPE insulation. For example, sometimes the corona problem outbreak on a new power distribution line, resulted from the gap between the sleeve and semi-conductive layer of cable joint. If above mentioned problem especially happened on the way of operating. We have to shut down the line and try to discharge the methane gas in cable joint. In this point, we would like to explain the mechanism of methane gas & cable joint and our test result briefly. At last, we are pleased to introduce the solution for preventing reoccurrence of this problem.

  • PDF

OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가 (Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable)

  • 곽병섭;전태현;김아름;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권4호
    • /
    • pp.263-273
    • /
    • 2019
  • OF 케이블의 예상 설계 수명인 30년이 도달하면서 고장 위험성이 증가하고 있다. 따라서 정확한 진단을 통한 열화 판정으로 장기 운용 OF 케이블을 적기에 진단함으로써 고장을 예방해야 한다. 또한 최적의 진단기준을 제시하여 잔류 수명을 예측하고 적절한 시기에 교체하는 조치가 요구되고 있다. 현재 한국전력공사에서는 OF 케이블을 진단하기 위해서 주기적으로 케이블 유중 가스분석을 실시하여 C2H2, TCG 등 일부 가스만 활용하고 있다. 하지만 이러한 유중 가스분석에서 확인되는 가스는 절연지뿐만 아니라 오일의 열화에 의해서도 발생된다. OF 케이블은 해체점검이 불가하기 때문에 절연지의 수명이 OF 케이블의 수명으로 간주되고 있다. 따라서 절연지를 직접적으로 분석하는 절연지 중합도 평가와 절연유중 퓨란화합물을 분석이 필요하며, 유중 가스분석에서 확인되는 CO, H2, CH4, C2H4, C2H6, C2H2 가스와 상관관계를 확인할 필요가 있다. 따라서 본 연구에서는 절연유중 가스를 분석하기 위해 headspace sampler가 장착된 GC를 사용하였고, 절연지 중합도는 자동점도계를 활용하였으며, 절연유중 퓨란화합물은 HPLC를 이용하여 측정하였다. 또한 OF 케이블의 종합적인 판정을 위하여 국내 OF 케이블 중 15개소를 선정하여 해체점검을 수행하였다. 또한 이렇게 얻어진 결과는 최근 전력설비 이상판정에 도입되고 있는 SVM 기법에 적용하여 정확하고 신뢰성 있는 열화판정을 도출하고자 하였다. 그 결과 절연지 중합도 잔률은 CO와 CO2 농도의 합에 따라 음의 2차 함수 관계로 감소하는 것으로 확인되었다. 또한 본 연구에서 얻어진 한전 OF 케이블 진단결과를 SVM 기법에 적용함으로써 한전 OF 케이블 진단결과를 기존 일본 동경전력의 SVM에 적용한 진단결과보다 향상되었고, 그 정확도는 약 87.9% 인 것으로 확인되었다.

345kV CV 케이블 접속함의 Proto Type 선정 (Determination of Proto Type for 345kV CV Cable Accessories)

  • 이수길;김인태;손시호;최수걸;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

케이블 접속재료의 전계분포 시뮬레이션 (Electric Field Distribution Simulation of the Cable Joint Materials)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability. and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis. air void. silicone oil. of which may possibly exist real cables. are simulated by Electra 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materails. In the modeling. electic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

케이블 접속재료의 전계분포 시뮬레이션 (Electric Field Distribution Simulation of the Cable Joint Materials)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability, and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis, air void, silicone oil, of which may possibly exist real cables, are simulated by Electro 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materials. In the modeling, eclectic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

고주파 전압이 XLPE cable의 가속열화에 미치는 영향 분석 (Analysis of Influence for High Frequency voltage Accelerated Aging of XLPE Cable)

  • 김위영;허종철;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1670-1672
    • /
    • 2004
  • XLPE compound have used for insulation of 22.9kV power cable. XLPE insulation is aged for use long time in distribution line. The cause of aging is water tree is happening and growth. Accelerated water tree test method are Accelerated volatge aging method and high frequency aging method. In this paper, high frequency accelerated water tree was performed. And the result was analysed AC breakdown voltage and size and number of water trees.

  • PDF

A Study on the Correlation Between the PD Pattern and the Type of Electrical Trees Propagation in the XLPE Insulation for the Underground Power Transmission

  • Lee, Jeon-Seon;Kim, Jeong-Tae;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권2호
    • /
    • pp.12-17
    • /
    • 2001
  • In this work, the correlation between the PD Patterns and the electrical tree propagation has been investigated by use of the specimen removed from the insulation of the real 154 kV XLPE underground power cables. As a result, it could be deduced that the PD pattern regarding electrical trees depends on their type which could be classified into three different distinct groups such as branch-bush mixed. Considering the results of our investigation, if the partial discharge magnitude is only considered for the diagnosis of the cable system, it is possible to draw a wrong decision. Therefore, it is possible to propose that the time characteristics of PD pattern should be taken into account for the diagnosis of the cable system in addition to the conventional $\Phi$-q-n characteristics.