• 제목/요약/키워드: power and rate

검색결과 8,123건 처리시간 0.032초

Optimum Uplink Power/Rate Control for Minimum Delay in CDMA Networks

  • Choi, Kwon-Hue;Kim, Soo-Young
    • ETRI Journal
    • /
    • 제25권6호
    • /
    • pp.437-444
    • /
    • 2003
  • We derive a new joint power and rate control rule with which we can minimize the mean transmission delay in CDMA networks for a given mean transmission power. We show that it is optimal to respectively control the power inverse-linearly and the rate linearly to the square root of channel gain while maintaining the signal-to-interference ratio at a constant. We also show that the proposed joint power/rate control rule achieves excellent performance results in terms of the probability of the instantaneous delay being within a target delay against one-dimensional control schemes.

  • PDF

CDMA 이동통신시스템을 위한 QoS 기반 최적 전송출력/전송률 할당 체계 (Optimal Power and Rate Allocation based on QoS for CDMA Mobile Systems)

  • 장근녕
    • 한국경영과학회지
    • /
    • 제28권4호
    • /
    • pp.1-19
    • /
    • 2003
  • This paper studies power and rate control for data users on the forward link of CDMA system with two cells. The QoS for data users is specified by delay and error rate constraints as well as a family of utility functions representing system throughput and fairness among data users. Optimal power and rate allocation problem is mathematically formulated as a nonlinear programming problem, which is to maximize total utility under delay and error rate constraints, and optimal power and rate allocation scheme (OPRAS) is proposed to obtain a good solution in a fast time. Computational experiments show that the proposed scheme OPRAS works very well and increases total utility compared to the separate power and rate allocation scheme (SPARS) which considers each cell individually.

석탄화력발전대비 LNG복합화력발전 환경성 및 경제성 비용분석에 관한 연구 (A Study on Environmental and Economic Cost Analysis of Coal Thermal Power Plant Comparing to LNG Combined Power Plant)

  • 김종원
    • 아태비즈니스연구
    • /
    • 제9권4호
    • /
    • pp.67-84
    • /
    • 2018
  • This study is about comparing coal thermal plant to LNG combined power plant in respect of environmental and economic cost analysis. In addition sensitive analysis of power cost and discount rate is conducted to compare the result of change in endogenous and exogenous variable. For environmental assessment, when they generate 10,669GWh yearly, coal thermal power plant emits sulfur oxides 959ton, nitrogen oxide 690ton, particulate matter 168ton and LNG combined power plant emits only nitrogen oxide 886ton respectively every year. Regarding economic cost analysis on both power plants during persisting period 30 years, coal thermal power plant is more cost effective 4,751 billion won than LNG combined taking in account the initial, operational, energy and environmental cost at 10,669GWh yearly in spite of only LNG combined power plant's energy cost higher than coal thermal. In case of sensitive analysis of power cost and discount rate, as 1% rise or drop in power cost, the total cost of coal thermal power plant increases or decreases 81 billion won and LNG combined 157 billion won up or down respectively. When discount rate 1% higher, the cost of coal thermal and LNG combined power plant decrease 498 billion won and 539 billion won for each. When discount rate 1% lower, the cost of both power plant increase 539 billion won and 837 billion won. With comparing each result of change in power cost and discount rate, as discount rate is weigher than power cost, which means most influential variable of power plan is discount rate one of exogenous variables not endogenous.

Power Allocation Framework for OFDMA-based Decode-and-Forward Cellular Relay Networks

  • Farazmand, Yalda;Alfa, Attahiru S.
    • Journal of Communications and Networks
    • /
    • 제16권5호
    • /
    • pp.559-567
    • /
    • 2014
  • In this paper, a framework for power allocation of downlink transmissions in orthogonal frequency division multiple access-based decode-and-forward cellular relay networks is investigated. We consider a system with a single base station communicating with multiple users assisted by multiple relays. The relays have limited power which must be divided among the users they support in order to maximize the data rate of the whole network. Advanced power allocation schemes are crucial for such networks. The optimal relay power allocation which maximizes the data rate is proposed as an upper bound, by finding the optimal power requirement for each user based on knapsack problem formulation. Then by considering the fairness, a new relay power allocation scheme, called weighted-based scheme, is proposed. Finally, an efficient power reallocation scheme is proposed to efficiently utilize the power and improve the data rate of the network. Simulation results demonstrate that the proposed power allocation schemes can significantly improve the data rate of the network compared to the traditional scheme.

Power-Efficient Rate Allocation of Wireless Access Networks with Sleep-Operation Management for Multihoming Services

  • Lee, Joohyung;Yun, Seonghwa;Oh, Hyeontaek;Newaz, S.H. Shah;Choi, Seong Gon;Choi, Jun Kyun
    • Journal of Communications and Networks
    • /
    • 제18권4호
    • /
    • pp.619-628
    • /
    • 2016
  • This paper describes a theoretical framework for rate allocation to maximize the power efficiency of overall heterogeneous wireless networks whose users are assumed to have multihoming capabilities. Therefore, the paper first presents a power consumption model considering the circuit power and radio transmission power of each wireless network. Using this model, two novel power efficient rate allocation schemes (PERAS) for multihoming services are proposed. In this paper, the convex optimization problem for maximizing the power efficiency over wireless networks is formulated and solved while guaranteeing the required quality of service (QoS). Here, both constant bit rate and variable bit rate services are considered. Furthermore, we extend our theoretical framework by considering the sleep-operation management of wireless networks. The performance results obtained from numerical analysis reveal that the two proposed schemes offer superior performance over the existing rate allocation schemes for multihoming services and guarantee the required QoS.

플라즈마 방전에 의한 $SO_x, NO_x$의 분해 (Decomposition of $SO_x, NO_x$ by Plasma Discharge)

  • 우인성;강현춘
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 1999
  • In this study, $SO_2$ and $NO_2$ reduction have been investigated by using coil type plasma reactor. The experiments have been carried out changing discharge power, gas flow rate frequency and electrode style to obtain the decomposition rate. Decomposition rates of $SO_2$ and $NO_2$ were obtained 20~98% at gas flow rate 100ml/min~1,000ml/min and discharge power 5~25w respectively. The energy efficiency is very good at the high frequency power. The decomposition rate of $SO_2$ for 5kHz power supply is only 90%, but for 10kHz power supply is very high, more than 98% for 15w. The decomposition rate is increasing according to the residence time or the power consumption of the discharge. About 15W discharge power for 17$cm^2$ reactor is necessary to obtain the decomposition rate of $SO_2$ and $NO_2$ of more than 85% or 98%. From these experiments, the consumption power of the decomposition rate of 98% in 300ppm $NO_2$ gas in nitrogen gas proved to be 18W and 300ppm $SO_2$ gas to be 15w.

  • PDF

영광 원자력 발전소 주변 환경 방사능 측정에 관한 연구 (The study on Measuring of Environmental Radioactivity in the Vicinity of Yonggwang Nuclear Power Plant)

  • 박종섭
    • 자원환경지질
    • /
    • 제32권3호
    • /
    • pp.273-280
    • /
    • 1999
  • In order to protect inhabitans' health and to collect data for prediction of the effcts from accidental emission of rasioactive materials from nuclear power plant, exposed dose rate be monitored within the limit dose rate. This research was carried out to investigate the accumulation of environmental radioactivity around Younggwang Nuclear Power Plant, and to infer and in infer and assay the additional exposed dose rate of inhabitants in Younggwang site from the operation of nuclear plant operation. External radiation dose rate, radiation environmental samples, and exposed dose rate of inhabitants in Younggwang site were investigated for estimaing environment activity in the vicinity of the nuclear power plant area. For the external radiation dose rate, the result showed that range of normal variation was found and any artificial radioisotope was not deteted in the analysis of environmental samples. Exposed dose rate of inhabitants was lower than 0.4% of the limit value of ICRP and it may be concluded that there was no effect on inhabitants and environment from the operation of nuclear power plant.

  • PDF

ON CHARACTERIZATIONS OF THE POWER DISTRIBUTION VIA THE IDENTICAL HAZARD RATE OF LOWER RECORD VALUES

  • Lee, Min-Young
    • 충청수학회지
    • /
    • 제30권3호
    • /
    • pp.337-340
    • /
    • 2017
  • In this article, we present characterizations of the power distribution via the identical hazard rate of lower record values that $X_n$ has the power distribution if and only if for some fixed n, $n{\geq}1$, the hazard rate $h_W$ of $W=X_{L(n+1)}/X_{L(n)}$ is the same as the hazard rate h of $X_n$ or the hazard rate $h_V$ of $V=X_{L(n+2)}/X_{L(n+1)}$.

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted Power Based Dynamic Rate Control for CDMA2000 1x System)

  • 박형근
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.498-500
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm for data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted power based dynamic rate control for CDMA2000 1x system)

  • 박형근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.221-223
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power. The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity. Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm fer data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

  • PDF