• Title/Summary/Keyword: power analyzer

Search Result 484, Processing Time 0.025 seconds

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

A Design of Bandpass Filter for Body Composition Analyzer (체성분 측정기용 대역통과 필터 설계)

  • Bae, Sung-Hoon;Cho, Sang-Ik;Lim, Shin-Il;Moon, Byoung-Sam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.43-50
    • /
    • 2005
  • This paper describes some IC(integrated circuits) design and implementation techniques of low power multi-band Gm-C bandpass filter for body composition analyzer. Proposed BPF(bandpass filter) can be selected from three bands(20 KHz, 50 KHz, 100 KHz) by control signal. To minimize die area, a simple center frequency tuning scheme is used. And to reduce power consumption, operational transconductance amplifier operated in the sub-threshold region is adopted. The proposed BPF is implemented with 0.35 um 2-poly 3-metal standard CMOS technology Chip area is $626.42um\;{\times}\;475.8um$ and power consumption is 700 nW@100 KHz.

A Chip Design of Body Composition Analyzer (체성분 분석용 칩 설계)

  • Bae, Sung-Hoon;Moon, Byoung-Sam;Lim, Shin-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.26-34
    • /
    • 2007
  • This Paper describes a chip design technique for body composition analyzer based on the BIA (Bioelectrical Impedance Analysis) method. All the functions of signal forcing circuits to the body, signal detecting circuits from the body, Micom, SRAM and EEPROMS are integrated in one chip. Especially, multi-frequency detecting method can be applied with selective band pass filter (BPF), which is designed in weak inversion region for low power consumption. In addition new full wave rectifier (FWR) is also proposed with differential difference amplifier (DDA) for high performance (small die area low power consumption, rail-to-rail output swing). The prototype chip is implemented with 0.35um CMOS technology and shows the power dissipation of 6 mW at the supply voltage of 3.3V. The die area of prototype chip is $5mm\times5mm$.

Development of Nuclear Power Plant Simulator using Shared Memory Variables (공유메모리 변수를 사용한 원자력발전소 시뮬레이터 개발)

  • 박근옥;서용석
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.153-156
    • /
    • 2001
  • We have developed CNS(Compact Nuclear Simulator) which can be used for the fundamental training of the nuclear power plant operators. The application software for CNS consists of simulation engine(analyzer code), instructor station software, and man-machine interface software. Each application software is regarded as one black box and the communication of black boxes is performed by the predefined shared memory variables. In this paper, we discuss our experience for CNS development.

  • PDF

Monitoring Ion Energy Distribution in Capacitively Coupled Plasmas Using Non-invasive Radio-Frequency Voltage Measurements

  • Choi, Myung-Sun;Lee, Seok-Hwan;Jang, Yunchang;Ryu, Sangwon;Kim, Gon-Ho
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.357-365
    • /
    • 2014
  • A non-invasive method for ion energy distribution measurement at a RF biased surface is proposed for monitoring the property of ion bombardments in capacitively coupled plasma sources. To obtain the ion energy distribution, the measured electrode voltage is analyzed based on the circuit model which is developed with the linearized sheath capacitance on the assumption that the RF driven sheath behaves like a simple diode for a bias power whose frequency is much lower than the ion plasma frequency. The method is verified by comparing the ion energy distribution function obtained from the proposed model with the experimental result taken from the ion energy analyzer in a dual cathode capacitively coupled plasma source driven by a 100 MHz source power and a 400 kHz bias power.

Examination on Combustion Quality Analysis of Residue Heavy Fuel Oil and Improvement of Combustion Quality Using Pre-injection (중질 잔사유의 연소성 분석과 보조 분사에 의한 연소성 향상에 관한 검토)

  • Yoo, Dong-Hoon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.113-119
    • /
    • 2014
  • Due to the development of the petroleum refining technology and continuously increased demand from markets, a quantity of gasoline and diesel oil produced from a restricted quantity of crude oil has been increasing, and residual fuel to be used at marine diesel engines has been gradually becoming low quality. As a result, it was recently reported that trouble oils which cause abnormal combustion such as knocking with extreme noise and misfire from internal combustion engines were increasing throughout the world. In this study, an author investigated ignitability and combustion quality by using combustion analyzer with constant volume(FCA, Fuel Combustion Analyzer) and middle speed diesel engine about MDO(Marine Diesel Oil), HFO(Heavy Fuel Oil), LCO(Light Cycle Oil) and Blend-HFO which was blended LCO of 1000 liters with HFO of 600 liters. Moreover, for betterment of ignitability and combustion quality of injected fuels, multi-injection experiment was carried out in the diesel engine using Blend-HFO. According to the results of FCA analysis, ignitability and combustion quality was bad in the order of MDO

Co-combustion of Bituminous Coal with Anthracite in a Down-firing, 200 MW Boiler

  • Park, Ho Young;Baek, Se Hyun;Kim, Young Joo;Kim, Tae Hyung;Kim, Hyun Hee;Lim, Hyun Soo;Park, Yoon Hwa
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.93-97
    • /
    • 2015
  • The combustion tests for Korean anthracite-bituminous coal blend were carried out in the 200 MW utility boiler. The burning characteristics of the blend were studied with a thermogravimetric analyzer (TGA). From the observation of TGA burning profiles, it was found that the presence of bituminous coal in the blend appeared to enhance the reactivity of anthracite in the higher temperature region, indicating certain interactions between the two coals. The plant test showed the boiler operation was reasonably stable with somewhat poor combustion efficiency, and some modification of the combustion environment in the furnace is necessitate for the further stable plant operation.

1.2 MHz Wireless Power Transfer Technology using a Spiral-type ECR device (1.2 MHz 스파이럴 ECR을 이용한 무선전력전송 기술)

  • PARK, Jaehyun;YANG, Haeyoul;KIM, Changsun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.54-55
    • /
    • 2011
  • To transfer the power wirelessly, the inverter converted DC power to a high frequency MHz-grade AC power. And the ECR devices for wirelessly transmitting the power are required. In this paper, the spiral-type ECR device and the high frequency inverter were designed. The operating frequency is approximately 1.2MHz. In addition, using a vector network analyzer, the 1.2MHz operating characteristics of the ECR device for wireless power transfer module are analyzed. It is performed and reviewed on validity of wireless power transfer technologies through experiments.

  • PDF