• Title/Summary/Keyword: potentiostat

Search Result 132, Processing Time 0.023 seconds

Micro Electrochemical Machining using Anodic Polarization Curve (양극분극곡선을 미용한 미세 전해가공)

  • 최영수;강성일;전종업;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.999-1002
    • /
    • 2002
  • In this research, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result. it was confirmed that anodic voltage curve could be used very effectively for determining the optimal condition of micro-ECM, and the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

  • PDF

Increase of Cell Concentration by the Automatic Analysis and Addition of glucose with an On-line Flow Injection Analysis System int he Cultivation of Saccharomyces cerevisiae Using a Korean Paper Digestion Wastewater (한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에서 온-라인 FIA시스템에 의한 Glucose의 자동분석 및 첨가에 의한 증균)

  • 이형춘
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.388-392
    • /
    • 2000
  • An on-line glucose flow injection analysis system was developed and used for the automatic analysis and addition of glucose in the cultivationof a Saccharomyces cerevisiae in a korean paper digestion wastewater in order to increase the cell concentration. The system was composed of a ceramic sampler a sampling valve an injection valve an immobilized glucose oxidase column a debbble a flow cell with platinum electrodes a potentiostat a computer and interface system and tubing pumps. The glucose concentration of the wastewater medium was mainitained at the low concentration of $176{\pm}31 mg/L$ with the on-line FIA system and by adding glucose and $>(NH_4)_2S0_4$ the cell concentration as total cell count can be increased by 3.1times.

  • PDF

Measurement of Glass Sintering Degree by Electro-chemical Method (전기 화학적 방법을 이용한 소결도의 측정)

  • 차재민;김웅식;이병철;류봉기
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.553-559
    • /
    • 2003
  • PDP rib is one of the important parts of manufacturing process and the sintering degree of rib plays an important role to prevent some problems such as cross talk. Nowadays, the screen-printing method, which is a low price and high production, is used to make a rib. However, it is hard to judge and value the sintering ratio of sintered body itself. In this study, we measured the sintering degree by the dielectric breakdown of pores with the potentiostat. We conformed that this has similar tendency to density of sintered samples and an error being expected by open and closed pores was inspected by change of the microstructure to scanning electron microscope. This result showed that the sintering degree of PDP rib could be analyzed into the electro-chemical method.

Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use (치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동)

  • Kim, Won-Gi;Lee, Chung-Hwan;Chung, Chae-Heon;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

A STUDY ON THE CORROSION OF AMALGAMS IN CHLORIDE SOLUTION (Chloride용액에서의 아말감부식에 대한 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.502-514
    • /
    • 1998
  • The purpose of this study is to observe the corrosion characteristcs of four dental amalgams(CAULK FINE CUT, CAULK SPHERICAL, DISPERSALLOY, TYTIN) and to determine a function of chloride concentration through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylinderical metal mold, and condensed by hydrolic pressure. Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 6 months. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam m KCl and KCl-NaCl solution, which had chlonde concentration of 0.4 g/l, 0.8 g/l, 1.2 gil, and 1.6 gil at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was - 1500mV ~+800mV(vs. S.C.E.) in the working electrode and the scan rate was 50mV/sec. The results were as follows, 1. The corrosion potential. the potential of anodic current peak, and transpassive potential in the solution of high chloride concentration shifted to more cathodic direction than those in the solution of low concentration, and the current density in the solution of high chloride concentration was higher than that in the solution of low concentration. 2. The corrosion potential, the potential of anodic current peak, and transpassive potential for CAULK FINE CUT amalgam were the most cathodic among the others, and the current density were the highest among the others. 3. In the solution of low chloride concentration, the corrosion potential, the potential of anodic current peak, and transpassive potential for DISPERSALLOY were the most anodic among the others, however in the solution of high chloride concentration, those for TYTIN were the most anodic among the others. 4. The anodic polarization curve for CAULK SPHERICAL was similar to that for high copper amalgams.

  • PDF

An Experimental Study on the Ion Reaction and the Electrochemical Rebar-Corrosion in Aqueous Solution Mixed with Sulfate and Chloride Ion-Reactive Material (황산, 염소이온 반응 소재 혼입 수용액에서의 이온반응성 및 전기화학적 철근 부식에 관한 실험적 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Kang, Tae-Won;Lim, Chang-Gil;Kim, Hong-Tae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this study, amine derivatives and ion exchange resins were selected to actively control penetration ions ($SO{_4}^{2-}$, $Cl^-$) as the element technology of repair materials for concrete structures in drainage environments. Ions ($SO{_4}^{2-}$, $Cl^-$) adsorption performance and corrosion resistance of calcium hydroxide solution with amine derivative and ion exchange resin were confirmed by ion chromatography and potentiostat analysis. As a result of the experiment, it was confirmed that the amine derivative is excellent in the adsorption of chlorine ion and the ion exchange resin is excellent in the adsorption of sulfate ion. It has been confirmed that corrosion resistance can be increased by proper combination of two materials in the calcium hydroxide solution containing sulfate ion and chloride ion simulating sewage environment.

Durability Evaluation of PEMFC Electrode Using Oxygen as Cathode Gas (PEMFC Cathode 산소 조건에서 전극 촉매 내구성 평가)

  • Oh, Sohyeong;Lim, Daehyeon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • In this study, we tried to develop a method of accelerated degradation of the electrode by simply using a electronic loader without using a potentiostat to evaluate the durability of the electrode catalyst. To this end, the durability of the electrode was evaluated by repeating the stepwise voltage change using the self-generated voltage by introducing oxygen without introducing nitrogen into the cathode. For accurate electrode durability evaluation, that is, in order not to deteriorate the polymer membrane, the high voltage was lowered to 0.9 V in stepwise voltage change and the relative humidity was 100% to suppress degradation of the polymer membrane due to radicals. After 30,000 cycles (50 hours) of voltage change, the electrode active area decreased by 41.4%. It was confirmed that the electrode was deteriorated, but the polymer membrane was not deteriorated, that there was no increase in hydrogen permeability, no decrease in membrane thickness, and no increase in HFR(High Frequency Resistance).

Effect of Load and Sliding Speed on Corrosive Wear of Metals in Seawater

  • Kawazoe, T.;Ura, A.;Nakashima, A.;Moritaka, H.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.245-246
    • /
    • 2002
  • The objective of this study is to evaluate corrosive wear resistance of metals used for bearings and gears in seawater. Sliding wear test of ferrous and copper materials against $Al_2O_3$ were carried out in artificial seawater using an electrochemical potentiostat. As the results, the wear rate and the coefficient of friction of the copper materials are lower than those of the ferrous materials. The corrosive wear of stainless steel is remarkably affected by normal load and sliding speed in view of tribological characteristics including adhesion and corrosion products.

  • PDF

The Effect on the Wear-Corrosion Behavior of Ductile Cast Iron in the Various pH Environments (구상흑연주철재의 마멸-부식특성에 미치는 pH의 영향)

  • 임우조;박동기
    • Tribology and Lubricants
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • This paper reports the studies on the wear-corrosion behavior of ductile cast iron in the various pH environments. In the variety of pH solutions, corrosion and wear-corrosion loss of GCD 600 were investigated. Also, the anodic polarization test of GCD 600 using potentiostat/galvanostat was carried out. And rubbed surface of GCD 60 using scanning electron micrographs after immersion and wear-corrosion test was examined in the environment of various pH values. The main results are as following In alkali zone, the wear-corrosion loss of GCD 600 increases, but corrosion loss decreases. The unevenness and crack of wear-corrosion surface in neutral zone becomes duller than that in alkali zone. As the corrosive environment is acidified, wear-corrosion behavior of GCD 600 with passing immersion time becomes sensitive.