• Title/Summary/Keyword: potentiometric measurement

Search Result 20, Processing Time 0.052 seconds

Uncertainty of Peroxide Value Determination in Fat in Follow up Formula (성장기용 조제식에 함유된 유지성분의 과산화물가 측정불확도)

  • Kim, Sung-Han;Kwack, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.885-892
    • /
    • 2004
  • Peroxide values (PV) of fat from fallow up formula were determined using redox-potentiometric titration method and standard method, which is based on KI oxidation by hydroperoxides and volumetric titration of liberated iodine, and their uncertainties were compared. Uncertainty sources in measurement, such as sample weight, sodium thiosulfate concentration, and titer, were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement and Draft EURACHEM/CITAC Guide. Analytical results and combined standard uncertainties of peroxide values (PV) determined by standard burette and potentiometric titrations were $2.05{\pm}0.17\;and\;1.96{\pm}0.07\;meq/kg$, respectively, suggesting potentiometric titration method is suitable for determining PV of fat with low PV, because uncertainty of PV determination obtained by potentiometric titration was lower than that obtained by burette titration.

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

Potentiometric NOx sensors for automotive exhaust using YSZ(yittria stabilized zirconia) electrolyte (YSZ 전해질을 이용한 농담전지식 자동차용 NOx센서)

  • Park, Jin-Su;Park, Kwang-Chol;Park, C.O.
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.434-440
    • /
    • 2007
  • Two kinds of new NOx sensing mechanism was proposed and examined. One of those was potentiomtric sensor based on the measurement of decomposed oxygen from NO using YSZ porous diffusion barrier and Pd catalytic electrode. The sensor based on decomposed oxygen measurement responded to the range of 300 - 1000 ppm NO in $N_{2}$ environment and the sensitivities were coincident with theoretical values at 700 and $800^{\circ}C$ but the decomposition rate depended on gas flow rate. The other sensor was equilibrium potentiometric type using $Gd_{2}O_{3}$-nitrates solid solution as sensing material. The sensor using $Gd_{2}O_{3}$-nitrates solid solution was suitable for NOxxsensing at $700^{\circ}C$ in 5 % oxygen and the sensitivity was 19.3 mV/decade. However, long term stability of the sensing material at high temperature was not sufficient.

Electron Transport of Low Transmission Barrier between Ferromagnet and Two-Dimensional Electron Gas (2DEG)

  • Koo, H.C.;Yi, Hyun-Jung;Ko, J.B.;Song, J.D.;Chang, Joon-Yeon;Han, S.H.
    • Journal of Magnetics
    • /
    • v.10 no.2
    • /
    • pp.66-70
    • /
    • 2005
  • The junction properties between the ferromagnet (FM) and two-dimensional electron gas (2DEG) system are crucial to develop spin electronic devices. Two types of 2DEG layer, InAs and GaAs channel heterostructures, are fabricated to compare the junction properties of the two systems. InAs-based 2DEG layer with low trans-mission barrier contacts FM and shows ohmic behavior. GaAs-based 2DEG layer with $Al_2O_3$ tunneling layer is also prepared. During heat treatment at the furnace, arsenic gas was evaporated and top AlAs layer was converted to aluminum oxide layer. This new method of forming spin injection barrier on 2DEG system is very efficient to obtain tunneling behavior. In the potentiometric measurement, spin-orbit coupling of 2DEG layer is observed in the interface between FM and InAs channel 2DEG layers, which proves the efficient junction property of spin injection barrier.

Application of a. Strip Ion-Selective Electrode Sensor for Hydroponic Nutrient Solution Analysis - NO3 Analysis - (양액의 영양분 분석을 위한 Strip형 이온선택성전극 센서 의 응용 -NO3 이온 분석 -)

  • 김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.335-342
    • /
    • 2003
  • A simple disposable thick-film potentiometric strip has been developed and evaluated for hydroponics application. The strip consisted of low ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, and magnesium were measured with specially designed 16-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The thick-film sensors exhibit linear relationships over five concentration decades. The concentration of N $O_3$ - ion in standard solution can be determined by direct potentiometric measurements without any conditioning before measurements. However, measurement of $K^{+}$, N $H_4$$^{+}$, and $Mg^{2+}$ ionic concentrations in nutrient solutions seems not feasible.

Comparison of the Ion Adsorption Method, Potentiometric Titraion and Backtitration Technique for Surface Charge measurement in Ultisol, Alfisol, and Inceptisol (Ultisol과 Alfisol 및 Inceptisol 토양에서 토양표면전하 측정에 사용된 이온흡착법, 전위차 적정법 및 역적정법간의 비교)

  • Lee, Sang-Eun;Neue, Heins Ulitz;Park, Jun-Kyu;Lim, Sookil H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.160-171
    • /
    • 1993
  • Surface charge characteristics of Ultisol(Luisiana soil from Philippines), Alfisol(Maahas soil from Philippines), and Inceptisol(Yongii soil from Korea) were studied by way of potentiometric titration, backtitration technique, and ion adsorption method(or CEC - AEC method). The PZNC(point of zero net charge) values determined by ion adsorption method were much lower than the natural pHs in all soils, indicating that all soil samples bore net negative surface charge. The PZSE (point of zero salt effect) values determined by potentiometric titration and backtitration technique were identical in Luisiana and Yongii soils but not in Maaghas soil. All soils showed higher PZSE values than PZNC values probably due to the influence of permanent negative charge. The permanent charge calculated by the theory of Uehara and Gillman (1980) occupied quite low portion of the CEC measured at pH 7 in all soils. Backtitration technique corrected errors of potentiometric titration at extreme pH. However, it still overestimate the surface charge compared with ion adsorption method. Therefore, the ion adsorption method was recommanded for the surface charge measurement of the usual soils which have high negative charge components.

  • PDF

Potentiometric Measurement of Standard Potential of Mercury and Ion-pair Formation Constants of Mercuric Halides in Anhydrous Ethylenediamine (에틸렌디아민 非水溶液中에서의 水銀電極의 標準電位 및 水銀鹽化鹽의 Ion-Pair 恒數測定)

  • Kim, Joon-Yong
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 1970
  • 非水溶液 Ethylenediamine 中에서 水銀電極의 標準電位 및 水銀鹽化物, $HgCl_2,\;HgBr_2,\;HgI_2$의 Ion-Pair 形成恒數를, Hg電極/$HgX_2$ 또는 $HgX_2$+NaX//亞鉛아마르감 參照電極과 같은 Cell의 構成으로서 電位差法에 依하여 測定하였다.

  • PDF

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

Potentiometric Determination of L-Malate Using Ion-Selective Electrode in Flow Injection Analysis Syste

  • Kwun, In-Sook;Lee, Hye-Sung;Kim, Meera
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.1
    • /
    • pp.79-83
    • /
    • 1999
  • A potentiometric biosensor employing a CO3-2 ion-selective electrode(ISE) and malic enzyme immobilization in al flow injection analysis (FIA) system was constructed. Analytical parameters were optimized for L-malate determination . The CO3-2 -ISE-FIA system was composed of a pump, an injector, a malic enzyme (EC1.1.1.40) reactor, a CO3-2 ion-selective electrode, a pH/mV meter and a recorder. Cofactor NADP was also injected with substrate for theenzyme reaction into the system. Optimized analytical parameters for L-malate determination in the CO3-2 ISE-FIA system were as follows ; flow rate, 14.5ml/hr ; sample injection volume, 100ul; enzyme loading in the reactor, 20 units ; length of the enzyme reactor , 7 cm ; tubing length form the enzyme reactor to the detector as a geometric factor in FIA, 15 cm . The response time for measuring the entire L-malate concentration range (10-2 ~10-5 mol/L ; 4 injections )was <15minutes . In this CO3-2 -ISE-FIA system, the potential differences due to th eformation of CO3-2 by the reaction of malic enzyme on L-malate were correlated to L-malate concentration in the range of 10-2 ~10-5mol/L ; the detection limit was 10-5 mol/L. This potentionmetric CO3-2 ISE--FIA system was found to be useful for L-malate measurement.

  • PDF