• 제목/요약/키워드: post-curing

검색결과 138건 처리시간 0.02초

DLP 공정을 이용한 정밀 치아모델 제작에서 UV 조사량과 후경화 수축률의 상관관계 분석 (Correlation between UV-dose and Shrinkage amounts of Post-curing Process for Precise Fabrication of Dental Model using DLP 3D Printer)

  • 신동훈;박영민;박상후
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.47-53
    • /
    • 2018
  • Nowadays, additive manufacturing (AM) technology is a promising process to fabricate complex shaped devices applied in medical and dental services. Among the AM processes, a DLP (digital light processing) type 3D printing process has some advantages, such as high precision, relatively low cost, etc. In this work, we propose a simple method to fabricate precise dental models using a DLP 3D printer. After 3D printing, a part is commonly post-cured using secondary UV-curing equipment for complete polymerization. However, some shrinkage occurs during the post-curing process, so we adaptively control the UV-exposure time on each layer for over- or under-curing to change the local shape-size of a part in the DLP process. From the results, the shrinkage amounts in the post-curing process vary due to the UV-dose in 3D printing. We believe that the proposed method can be utilized to fabricate dental models precisely, even with a change of the 3D CAD model.

Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials

  • de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Cavalcanti, Yuri Wanderley;de Lima, Elisa Diniz;Bento, Patricia Meira;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.141-151
    • /
    • 2020
  • Purpose: This study aimed to quantify the influence of tooth position within the field-of-view (FOV) on cone-beam computed tomography (CBCT) imaging artifacts' intensity when assessing teeth restored with various intracanal materials. Materials and Methods: Seventy single-rooted teeth were divided into 7 groups (10 teeth per group): NiCr post (NC), AgPd post (AP), metal core fiberglass post (MCFG), fiberglass post (FG), anatomical fiberglass post (AFG), fiberglass post cemented with core build-up cement (FGCo), and anatomical fiberglass post cemented with core build-up cement (AFGCo). All posts were cemented using a regular dual-curing resin cement (Allcem), except FGCo and AFGCo which were cemented with a core build-up dual-curing resin cement (AllcemCore). Each tooth was scanned on a CS9000 in 5 positions within the FOV: a central position, anterior horizontal peripheral, peripheral superior, peripheral inferior, and posterior horizontal peripheral position. Hyperdense, hypodense, remaining teeth areas and ROI areas were quantitatively analyzed using ImageJ software. Results: Posterior horizontal peripheral position increased the intensity of artifacts on FGCo and AFGCo post groups (P<0.05), and specifically the hypodense artifact intensity on FG and AFG post groups (P<0.05). NC and AP groups presented greater intensity of artifacts than any other post groups(P<0.05). Conclusion: Artifact intensity increases in the presence of high atomic number materials and when the object is not centered within the FOV. The impact of positioning within the FOV on artifact was greater for fiberglass posts cemented with core build-up dual-curing cement than for metal posts and fiberglass posts cemented with regular dual-curing cement.

HTPB/AP계열의 고체 추진제의 Step 경화 방법을 통한 경화일(기간) 단축 (The Study of Curing Day Reduction by Step Curing of HTPB/AP Propellant)

  • 김가희;박정호;최성한
    • 한국추진공학회지
    • /
    • 제24권6호
    • /
    • pp.101-107
    • /
    • 2020
  • 본 논문에서는 HTPB/AP 계열의 추진제의 경화 온도를 변화시키는 Step 경화 방법으로 경화일 단축 연구를 진행하였다. 이 연구는 HTPB/AP 계열의 추진기관 제작 시 생산성 향상(제작기간 단축 및 치구회수율 증대)을 목적으로 한다. 정상 경화 대비 추진제의 기계적 물성을 비교하여 정상 경화 시 60℃ 5일 소요되는 경화일을 Step 경화로 4일(60℃ 1일 / 65℃ 3일)로 설정하였다. 경화일 단축을 적용 시 추진제 노화 특성을 알아보기 위해 Step 경화 후 후경화(Post-cure) 시험을 진행하였다. 이를 통해 기계적 물성 및 열팽창 계수를 측정하여 추진제의 후경화 특성을 분석하였다. 또한, Step 경화 후 가속 노화 시험을 진행하여 12주차 경과 후 인장시험을 수행하였다. 그 결과, Sm(bar)은 8 bar 이상, Em(%)은 40%이상으로 요구되는 우수한 기계적 물성을 가지는 것을 알 수 있었다.

Epoxy-siloxane IPN의 열적 안정성에 미치는 후기경화의 영향 (Effects of Post-curing on Thermal Stability of Epoxy-sioxane IPN Structure)

  • 조영신;심미자;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.944-946
    • /
    • 1999
  • The thermal stability of the post cured epoxy-polysiloxane IPN structure was observed by using DSC and TGA. As the post curing time increased the glass transition temperature increased and the secondary exothermic peak disappeared. The thermally decomposing activation energy calculated by using Kissinger expression was 225.6 kJ/mol. The thermal stability of the grafted IPN of epoxy and silicon compound depends on the composing ratio and post curing conditions of time and temperature.

  • PDF

경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성 (Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System)

  • 조영신;박수길;임기조;심미자;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응 (CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST)

  • 안석;박상원;양홍서;방몽숙;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

촉진양생이 콘크리트의 28일 압축강도에 미치는 영향에 관한 연구 (A Study on the Effect of Accelerated Curing on 28-Days Compressive Strength of Concrete)

  • 최세규;유승룡;김생빈
    • 콘크리트학회지
    • /
    • 제8권4호
    • /
    • pp.141-148
    • /
    • 1996
  • 기존의 촉진양생 연구는 1960~1970년대에 주로 실행된 것으로, 전체 증기양생기간이 18시간 또는 24시간인 경우에 대하여 연구되었고, 상기 연구 결과는 수동식 항온항습조를 사용하였으므로 온도상승구배의 효과에 대하여 명확한 규명을 할 수 없다고 판단되었다. 따라서 국내 PC공장 여건에서 그 직접적인 적용이 불가능한 실정이다. 본 연구는 효과적인 콘크리트 촉진양생에 대한 기본 자료를 정립할 목적으로, 국내 PC 공장에서 사용하는 배합표를 근거로 시험공시체를 제작한 후, 각 해당 양생주기 조건을 변화시켜 가면서 실험하였다. 탈형시 및 수중양생 재령28일의 측정하고 비교 검토한 결과, 재령 28일 후 설계강도값을 초과하는 가장 효과적인 촉진양생조건, 본 실험조건 하에서 전양생시간은 커다란 영향을 미치지 않았으며, 온도상승구배는 $30^{circ}C/hr$ 이하로, 최고양생온도는 $82^{\circ}C$이하로 양생해야 하며, 또한 촉진양생 후 2차 양생으로 강도증진을 도모함이 촉진양생의 효과를 증대시킬 수 있다고 판단되었다.

충격 공진 기법을 이용한 화재 손상 콘크리트의 재양생 조건별 재료물성 평가 (Evaluation of Material Properties of Fire-damaged Concrete Under Post-fire Curing Regimes Using Impact Resonance Vibration Method)

  • 박선종;임홍재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권5호
    • /
    • pp.42-48
    • /
    • 2017
  • 콘크리트 구조물이 화재 손상을 입을 경우 노출온도 및 지속시간에 따라 구조물의 심각한 성능 저하를 야기하며, 콘크리트의 재료 물성 저하를 수반한다. 화재 손상을 입은 콘크리트 구조물의 재사용여부 및 보수보강 판단을 위해서는 손상 직후 및 재양생 조건에 따른 주요 손상 부위의 면밀한 손상 평가가 필요하다. 본 연구에서는 재양생 조건에 따른 화재 손상을 입은 콘크리트의 재료물성 회복에 관한 실험적 연구를 수행하였다. 화재 손상을 입은 콘크리트 시편을 상대습도 및 재양생 기간을 달리한 재양생 조건을 적용하였으며, 충격공진기법을 도입하여 콘크리트 시편의 화재 손상 전후 및 재양생 이후의 동탄성계수를 측정하여 손상 정도를 평가하였다. 측정된 결과로부터 재양생 조건 중 높은 상대습도 조건에서 지배적으로 재료물성의 회복이 발생하였다. 추가적으로 콘크리트 시편의 동탄성계수 및 인장강도의 직접적인 비교 및 선형회귀분석을 수행하여 재양생 조건에 따른 영향을 분석하였으며, 이를 토대로 높은 습도 조건에서 동탄성계수의 회복이 인장강도에 비해 두드러지게 나타남을 확인하였다.

촉진양생이 콘크리트의 수화 및 압축강도에 미치는 영향에 관한 연구 (A Study on the effect of Accelerated Curing on Hydration and Compressive Strength of Concrete)

  • 김생빈;유승룡;김동신;최세규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.107-111
    • /
    • 1996
  • The testing specimens were made from the standard mix proportion according to those of domestic PC factories to establish a basic data for the Accelerated Curing Effect. The experimental tests were conducted according to the conditions of each sub-curing periods. By comparing the results of compression tests on de-molded and 28-day water-curing specimens, we find that the most effective curing condition to obtain more than the required design strength after 28 days of water curing may be as follwings; the presteaming period does not affect seriously and less than $30^{\circ}C$/hr-the rate of temperature rise and less than $82^{\circ}C$ - maximum temperature are necessary. It seems that post-curing procedure is very important factor to increase the effect of accelerated curing.

  • PDF

화재 피해를 입은 일반강도 RC 보의 보수성능 (Structural Behavior of Retrofitted RC beams with Fire Damages)

  • 안주희;신영수;이차돈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1013-1016
    • /
    • 2003
  • This paper is to evaluate practically the techniques and materials of repair for RC elements with fire damages as well as to investigate the structural behavior of RC beams according to pre- or post-repair after fire-damages. For this purpose, normal concrete flexural specimens were exposed to high temperatures by the ISO 834 specification. After natural cooling and post-fire-curing in a natural environment for 2 months, the specimens were repaired with polymer cement mortar for 1 month curing.

  • PDF