• Title/Summary/Keyword: post cure

Search Result 112, Processing Time 0.022 seconds

A Study on the Dielectric Properties and Fabrication Conditions of Thermo-Setting Epoxy Resin (내열성 에폭시 수지의 제작조건과 전기적 절연특성에 관한 연구)

  • An, Young-Joo;Kwak, Young-Soon;Cho, Jeong-Soo;Choi, Se-Won;Lee, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.761-762
    • /
    • 1988
  • This paper is to investigate dielectric properties, dielectric breakdown strength, varing of interior organization and gelling point temperature as parameter of post-cure conditions of thermo-setting epoxy resin.

  • PDF

Primary Mediastinal Liposarcoma - 1 Case Report - (원발성 종격동 지방육종 -1예 보고 -)

  • Lee, Seong-Yun;Hong, Eun-Gyeong;Ji, Haeng-Ok
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1061-1069
    • /
    • 1989
  • A case of liposarcoma was reported in 52 year-old female. She had the operation history due to mediastinal lipoma at other Hospital before 26 months ago. Chest X-ray revealed a huge soft tissue mass- density at the entire right lung field, and left middle and lower lung field at admission. At the lateral film, the mass was located in the anterior and middle mediastinum. Transsternal bilateral thoracotomy was performed, followed by extirpation of liposarcoma, wedge resection of superior vena cava, angioplasty of superior vena cava, and then partial pericardiectomy. The post-operative treatment was 5500 rad irradiation. Post-operative course was uneventful, that was noticed by OPD follow-up for 10 months. Primary liposarcoma of the mediastinum is very rare tumor. This tumor grows to an enormous size, and symptoms are referable to compression of the contiguous intrathoracic structures. The treatment of choice is surgery in all cases. Such an approach serves to establish a tissue diagnosis, to relieve the patients* symptoms, and may results in a cure sometimes. Radiotherapy or/and chemotherapy seems to be ineffective, but should be further studied.

  • PDF

A Study of Thermo-rheological Behaviour from Long Term Responses of Solid Composite Propellant (고체 추진제 장시간 물성거동 반응 연구)

  • Ryu, Taeha;Kim, Nakhyun;Khil, Taeock;Choi, Yongkyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.1
    • /
    • pp.8-16
    • /
    • 2017
  • Structural integrity of solid rocket depends on the residual reactions between constituents of its composition(post cure, migration etc.), the oxygen(or anti-oxydent) in the free volume and humidity (desiccant) under the perfect sealed condition. Mechanical Properties of composite solid propellant arising from those factors are very complex. Moreover the propulsion are faced with thermal loads from diurnal & seasonal cycle till firing. In this study, the fast evaluation method of long term mechanical properties is suggested based on Thermo-Rheological Simplicity from curing oven to cool-down stage in view point of thermal stabilization. For this subject, endurance tester having temperature control capability are devised. From the results from incremental load and strain, non-linear characteristics are discussed.

Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternatives

  • Mumcu, Emre;Cilingir, Altug;Gencel, Burc;Sulun, Tonguc
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.136-139
    • /
    • 2011
  • PURPOSE. A new light curing urethane dimethacrylate and a cold curing resin with simpler and faster laboratory procedures may have even improved flexural properties. This study investigated the 3-point flexural strengths and flexural moduli of two alternate base materials. MATERIALS AND METHODS. A cold curing resin (Weropress) and a light curing urethane dimethacrylate base material (Eclipse). Along with Eclipse and Weropress, a high impact resin (Lucitone199) and three conventional base materials (QC 20, Meliodent and Paladent 20) were tested. A 3-point bending test was used to determine the flexural strengths and flexural moduli. The mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations for each group were analyzed by means of one-way analysis of variance (ANOVA) (with mean difference significant at the 0.05 level). Post hoc analyses (Scheffe test) were carried out to determine the differences between the groups at a confidence level of 95%. RESULTS. Flexural strength, displacement and force maximum load values of Eclipse were significantly different from other base materials. Displacement values of QC 20 were significantly different from Lucitone 199 and Weropress. CONCLUSION. The flexural properties and simpler processing technique of Eclipse system presents an advantageous alternative to conventional base resins and Weropress offers another simple laboratory technique.

In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements (치과용 레진 시멘트의 중합 수축률 특성에 관한 연구)

  • Kim, Tae-Hoon;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: The shrinkage of dental resin cement may cause several clinical problems such as distortion that may jeopardize the accurate fit to the prepared tooth and internal stress within the restorations. It is important to know the polymerization shrinkage-strain of dental resin cement to reduce clinical complications. The purpose of this study was to investigate the polymerization shrinkage-strain kinetics of six commercially available dental resin cements. Material and methods: Three self-cure resin cements (Fujicem, Superbond, M-bond) and three dual-cure resin cements (Maxcem, Panavia-F, Variolink II) were investigated. Time dependent polymerization shrinkage-strain kinetics of the materials were measured by the Bonded-disk method as a function of time at $23^{\circ}C$, with values particularly noted at 1, 5, 10, 30, 60, 120 min after mixing. Five recordings were taken for each materials. The data were analyzed with one-way ANOVA and Scheffe post hoc test at the significance level of 0.05. Results: Polymerization shrinkage-strain values were 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90% for Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II, respectively at 120 minutes after the start of mixing. Panavia F exhibited maximum polymerization shrinkage-strain values, but Superbond showed minimum polymerization shrinkage-strain values among the investigated materials (P < .05). There was no significant differences of shrinkage-strain value between Maxcem and M bond at 120 minutes after the start of mixing (P > .05). Most shrinkage of the resin cement materials investigated occurred in the first 30 minutes after the start of mixing. Conclusion: The onset of polymerization shrinkage of self-cure resin cements was slower than that of dual-cure resin cements after mixing, but the net shrinkage strain values of self-cure resin cements was higher than that of dual-cure resin cements at 120 minutes after mixing. Most shrinkage of the dental resin cements occurred in the first 30 minutes after mixing.

Effect of surface treatment of FRC-Post on bonding strength to resin cements (FRC-포스트의 표면처리가 레진시멘트와의 접착력에 미치는 영향)

  • Park, Chan-Hyun;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate the effect of surface treatment of FRC-Post on bonding strength to resin cements. Materials and Methods: Pre-surface treated LuxaPost (DMG), Rely-X Fiber Post (3M ESPE) and self adhesive resin cement Rely-X Unicem (3M ESPE), conventional resin cement Rely-X ARC (3M ESPE), and Rely-X Ceramic Primer (3M ESPE) were used. After completing the surface treatments of the posts, posts and resin cement were placed in clear molds and photo-activation was performed. The specimens were sectioned perpendicular to the FRC-Post into 2 mm-thick segments, and push-out strength were measured. The results of bond strength value were statistically analyzed using independent samples t-test and oneway ANOVA with multiple comparisons using Scheffe's test. Results: Silanization of posts affect to the bond strength in LuxaPost, and did not affect in Rely-X Fiber Post. Rely-X ARC showed higher value than Rely-X Unicem. Conclusions: Silanization is needed to enhance the bond strength between LuxaPost and resin cements.

Chemical compatibility of interim material and bonding agent on shear bond strength (임시수복 재료와 본딩제의 화학적 호환성이 전단결합강도에 미치는 영향)

  • Lee, Jonghyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.293-300
    • /
    • 2016
  • Purpose: The purpose of this study is finding proper bonding agents to be used when adding bis-acryl composite provisional materials. Materials and Methods: Three bonding agents with different chemical compositions were included in this study. Forty disk shaped specimens of bis-acryl composite provisional material were prepared and divided into 4 groups according to the bonding agents. Control group didn't have bonding agent. Through the Teflon mould with 4.0 mm diameter hole with 4.0 mm thickness the same bis-acryl composite provisional material was added on the disks after the surface of each specimen was treated with designated bonding agent according to the manufacturer's instructions. Shear bond test was performed and the fractured surfaces were inspected with a microscope. One-way analysis of variance was conducted and the result was further analysed with Turkey post hoc test at the significance level of 0.05. Results: The highest strength was acquired from the specimens bonded with chemical cure system and it was statistically significant (P < 0.05). This group showed 100% cohesive failures. The lowest bonding strength was recorded from the specimens used conventional light cure bonding agent, and this group's result was similar with the control group. The group used a light cure bonding agent claiming improved compatibility revealed significantly higher bond strength to the traditional light cure bonding agent group in a statistically significant way (P = 0.043). Conclusion: According to the bonding agent used the shear bond strength was significantly affected. Therefore the choice of proper bonding agent is important when hiring a bonding agent to add bis-acryl composite provisional materials.

Efficacy and Safety of Ultrasound-Guided Radiofrequency Ablation for Primary Hyperparathyroidism: A Prospective Study

  • Hui-hui Chai;Yu Zhao;Zeng Zeng;Rui-zhong Ye;Qiao-hong Hu;Hong-feng He;Jung Hwan Baek;Cheng-zhong Peng
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.555-565
    • /
    • 2022
  • Objective: To assess the efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) in patients with primary hyperparathyroidism (PHPT). Materials and Methods: This prospective study enrolled 39 participants (14 male, 25 female; mean age, 59.5 ± 15.3 [range, 18-87] years) between September 1, 2018, and January 31, 2021. All participants had parathyroid lesions causing PHPT, proven biochemically and through imaging. The imaging features of the PHPT nodules, including the shape, margin, size, composition, and location, were evaluated before treatment. Serum intact parathyroid hormone, calcium, and phosphorus levels; parathyroid nodule volume; and PHPT-related symptoms were recorded before and after treatment. We calculated the technical success, biochemical cure, and clinical cure rates for these patients. Complications were evaluated during and after the ablation. Results: Complete ablation was achieved in 38 of the 39 nodules in the 39 enrolled participants. All the patients were treated in one session. The technical success rate was 97.4% (38/39). The mean follow-up duration was 13.2 ± 4.6 (range, 6.0-24.9) months. At 6 and 12 months post-RFA, the biochemical cure rates were 82.1% (32/39) and 84.4% (27/32), respectively, and the clinical cure rates were 100% (39/39) and 96.9% (31/32), respectively. Only 2.6% (1/39) of the patients had recurrent PHPT. At 1, 3, 6, and 12 months after technically successful RFA, 44.7% (17/38), 34.3% (12/35), 15.8% (6/38), and 12.5% (4/32) of participants, respectively, had elevated eucalcemic parathyroid hormone levels. Recurrent laryngeal nerve paralysis occurred in 5.1% (2/39) of the patients, who recovered spontaneously within 1-3 months. Conclusion: US-guided RFA was effective and safe for PHPT patients. RFA may be an alternative treatment tool for patients who cannot tolerate or refuse to undergo surgery.

The Effect of Acupuncture and Electro-acupuncture of Low and High Frequencies at $ST_{41}$ on Experimentally Induced Intestinal Hypermotility in Rats: Comparison between Pre-treatment and Post-treatment (해계 유침 및 전침의 전.후 처치가 실험적으로 항진된 흰쥐의 장운동에 미치는 영향)

  • Choi, Joo-Young;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.27 no.3
    • /
    • pp.117-126
    • /
    • 2010
  • Objectives : The purpose of this study was to compare the effect of needle retention(NR) and electro-acupuncture of low(EA(L)) and high(EA(H)) frequencies at Haegye($ST_{41}$) on intestinal hypermotility induced with carbachol in rats Methods : We made over-activated state of intestinal motility with carbachol in rats and caried out needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at Haegye($ST_{41}$) or sham point in rat devided into pre-treatment group and post-treatment group. And we resulted as followings from measuring charcoal travel rate with observation of intestinal motility. Results : 1. None of acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at $ST_{41}$ had significant influences on intestinal motility of rat in normal state. 2. Pre-treated with acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture and post-treated with acupuncture and low frequency electro-acupuncture at $ST_{41}$ didn't significantly influences intestinal motility in rat which over-activated with carbachol. 3. Post-treated with high frequency electro-acupuncture at $ST_{41}$ suppressed intestinal motility in rat which over-activated with carbachol. Conclusions : These results suggest that treatment high frequency electro-acupuncture at ST41 may be effective on gastric disorders such as intestinal hypermotility and its effect had more cure than prevention.