• Title/Summary/Keyword: possible hazard

Search Result 326, Processing Time 0.025 seconds

Quantitative Safety Assessment for Hydrogen Station (수소 충전소에 대한 정량적 안전성 평가)

  • Seong, D.H.;Rhie, K.W.;Kim, T.H.;Oh, D.S.;Oh, Y.D.;Seo, D.H.;Kim, Y.G.;Kim, E.J.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.111-116
    • /
    • 2012
  • This study is about the quantitative safety assessment of hydrogen station in Korea operating with on-site type. This was written by background information that before qualitative safety assessment to write. For the qualitative safety assessment method, the study used FMEA(failure mode & effect analysis) and HAZOP(hazard & operability), and adopted the FTA(fault tree analysis) as the quantitative safety assessment method. To write the FTA, we wrote FT by Top event that hydrogen leakage can be called most serious accident of hydrogen station. Each base event collect reliability data by reliability data handbook, THERP-HRA and estimation of the engineering. Assessment looked at the high frequency and the possible risk through Gate, Importance, m.cutsets analysis.

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

A methodology to estimate earthquake induced worst failure probability of inelastic systems

  • Akbas, Bulent;Nadar, Mustafa;Shen, Jay
    • Structural Engineering and Mechanics
    • /
    • v.29 no.2
    • /
    • pp.187-201
    • /
    • 2008
  • Earthquake induced hysteretic energy demand for a structure can be used as a limiting value of a certain performance level in seismic design of structures. In cases where it is larger than the hysteretic energy dissipation capacity of the structure, failure will occur. To be able to select the limiting value of hysteretic energy for a particular earthquake hazard level, it is required to define the variation of hysteretic energy in terms of probabilistic terms. This study focuses on the probabilistic evaluation of earthquake induced worst failure probability and approximate confidence intervals for inelastic single-degree-of-freedom (SDOF) systems with a typical steel moment connection based on hysteretic energy. For this purpose, hysteretic energy demand is predicted for a set of SDOF systems subject to an ensemble of moderate and severe EQGMs, while the hysteretic energy dissipation capacity is evaluated through the previously published cyclic test data on full-scale steel beam-to-column connections. The failure probability corresponding to the worst possible case is determined based on the hysteretic energy demand and dissipation capacity. The results show that as the capacity to demand ratio increases, the failure probability decreases dramatically. If this ratio is too small, then the failure is inevitable.

Simulation of 1993 East Sea Tsunami by Parallel FEM Model (병렬 FEM 모형을 이용한 1993년 동해 지진해일 시뮬레이션)

  • Hong, Sung-Jin;Choi, Byung-Ho;Pelinovsky, Efim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.35-45
    • /
    • 2006
  • The simulation of tsunami using detailed bathymetry and topography is required to establish the countermeasure of disaster mitigation and the tsunami hazard map. In this study, a simulation of the 1993 tsunami event in the East Sea using parallel finite element model, which is possible to simulate with suitable accuracy by the Beowulf parallel computation method, is performed to produce detailed features of coastal inundation. Results of simulation are compared with measured data. The evolution of statistic distribution of tsunami heights is studied numerically and the distribution functions of tsunami heights show a tendency to the log-normal curve along coastal area.

A Survey Study on Standard Security Models in Wireless Sensor Networks

  • Lee, Sang Ho
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.4
    • /
    • pp.31-36
    • /
    • 2014
  • Recent advancement in Wireless Sensor Networks (WSNs) has paved the way for WSNs to enable in various environments in monitoring temperature, motion, sound, and vibration. These applications often include the detection of sensitive information from enemy movements in hostile areas or in locations of personnel in buildings. Due to characteristics of WSNs and dealing with sensitive information, wireless sensor nodes tend to be exposed to the enemy or in a hazard area, and security is a major concern in WSNs. Because WSNs pose unique challenges, traditional security techniques used in conventional networks cannot be applied directly, many researchers have developed various security protocols to fit into WSNs. To develop countermeasures of various attacks in WSNs, descriptions and analysis of current security attacks in the network layers must be developed by using a standard notation. However, there is no research paper describing and analyzing security models in WSNs by using a standard notation such as The Unified Modeling Language (UML). Using the UML helps security developers to understand security attacks and design secure WSNs. In this research, we provide standard models for security attacks by UML Sequence Diagrams to describe and analyze possible attacks in the three network layers.

  • PDF

A Risk Assessment Approach to Safety Management of Electric Railway Facilities (전기철도 전철전력설비의 위험도 평가 기반 안전관리에 관한 연구)

  • Jang, Yoon-Suk;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.960-967
    • /
    • 2009
  • Power supply system of electric railway has a diversity of safety problems since it should supply high electric power to the trains moving high speed with a lot of passengers on board. This paper provides a risk assessment approach to safety management of the electric railway facilities. Construction of database from field accident information, risk assessment and management of the risk are carried out systematically to ensure the safety. The risk assessment includes hazard identification, cause analysis by FTA(Fault Tree Analysis), consequence analysis by EVA(Event Tree Analysis), and loss analysis. In terms of the severity and the probability of the accidents deduced by these analyses, the risk of the accidents is assessed by using a risk matrix designed for electric railway facilities. Based on the risk assessment, possible risk mitigation options are identified and evaluated by analyzing their impact on the risk reduction and their cost benefit ratio. The long-term safety of the electric railway facilities can be ensured by renewal of the risk assessment and the risk mitigation option analysis with continuous accident database update. The proposed approach is applied to the electric railway facilities of Korean railway based on the accident data from 2002 to 2008.

Parametric Analysis for Up-lifting force on Slab track of Bridge under Train Load (열차하중 재하시 교량상slab궤도의 상향력 민감도분석)

  • Choi, Sung-Ki;Park, Dae-Geun;Han, Sang-Yun;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.279-282
    • /
    • 2008
  • The vertical forces in rail fasteners at areas of bridge transitions near the embankment and on the pier will occur due to different deformations of adjoining bridges caused by the trainloads. The up-lifting forces is not large problem in the blast track because the elasticity of blast and rail pad buffs up-lifting effect. But, it is likely to be difficult to ensure the serviceability of the railway and the safety of the fastener in the end in that concrete slab track consist of rail, fastener, and track in a single body, delivering directly the up-lifting force to the fastener if the deck is bended because of the end rotation of the overhang due to the vertical load. When the up-lifting force exceeds the clamp force of the fastener clip, the rail pad is out of fastener, which makes decrease the serviceability of the railway, such as noise and vibration. Furthermore, it is possible to reduce the safety of the track as the longitudinal resistance. This study is focused on guideline suggestion to decrease up-lifting force in the fastener adjacent to the civil joint of slab track of bridge throughout the parametric analysis between the vertical spring stiffness of the fastener as the material approach, the space of fastener adjacent to bridge transition, the rigidity of the girder as the geometrical approach and up-lifting force under the train load.

  • PDF

A Study on Investigate The Actual Conditions of Coastal Disaster Prevention Forest(Ⅰ) - on New Plan Site - (해안방재림 실태조사에 관한 연구(Ⅰ) - 신규조성대상지를 중심으로 -)

  • Chun, Kun-Woo;Lee, Jin-Ho;Kim, Min-Sik;Yeom, Kyu-Jin;Seo, Jae-Chul;Ezaki, Tsugio
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.763-766
    • /
    • 2008
  • This study was investigated to the conditions of coastal disaster prevention forests in coastal sand dune in Korea. As a result new planed area were about 250.05ha of 576 sites and average area per site is about 0.43ha. Therefore, it is necessary to readjust it in 1 ha/site for standard of new plan area and 10 ha/year for establishment quantity. In addition, the maintenances methods for about 1,479 ha in the forested area of coastal disaster prevention forest and the basic investigations for forests close to coastal were carried out as soon as possible.

  • PDF

Urban Design Case Review for Mitigation of Sediment Disaster and its Application in Korea (토사재해 저감 도시설계 사례검토 및 국내 적용방안 연구)

  • Lee, Yoon-Sang;Kim, Hyo-Jin;Jin, Kyu-Nam
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.201-210
    • /
    • 2017
  • Recently, as a part of measures against large-scale natural disasters in Korea, disaster prevention matters are strengthened in urban planning. With the introduction of the disaster vulnerability analysis system, plans for disaster prevention are being reinforced in urban planning. However, there are many problems to be solved at the stage of operation and practical application of the law. When disasters occur, we are focusing on response and recovery plans. Therefore, it is not enough to construct a comprehensive disaster prevention system to prevent disasters in advance. The established disaster prevention plan is difficult to plan management centered on disaster prevention due to factors such as economic efficiency, convenience, and comfort. This study is a basic study for supporting disaster prevention mitigation plan. For this purpose, the analysis of the actual situation of disaster prevention plan at home and abroad and improvement plan were derived. ased on these improvement plans, we have developed a method to apply the element technology of urban design to the test bed to reduce sediment disaster. The test bed was investigated and examined in the disaster hazard area of Busan and Seongnam city. And the defense technology is applied to the selected site, and the basis of the disaster prevention plan and design is proposed. If the proven techniques are reflected from the urban planning stage, it will be possible to contribute to the mitigation of sediment disaster caused by the city.

Effects of Tsunami Waveform on Energy Dissipation of Aquatic Vegetation (쓰나미 파형이 수중식생의 에너지소산에 미치는 영향)

  • Lee, Woo-Dong;Park, Jong-Ryul;Jeon, Ho-Seong;Hur, Dong-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.121-129
    • /
    • 2017
  • The present study numerically investigated the influence of the waveform distribution on the tsunami-vegetation interaction using a non-reflected wave generation system for various tsunami waveforms in a two-dimensional numerical wave tank. First, it was possible to determine the wave attenuation mechanism due to the tsunami-vegetation interaction from the spatial waveform, flow field, vorticity field, and wave height distribution. The combination of fluid resistance in the vegetation and a large gap and creates a vortex according to the flow velocity difference in and out of the vegetation zone. Thus, the energy of a tsunami was increasingly reduced, resulting in a gradual reduction in wave height. Compared to existing approximation theories, the double volumetric ratio of the waveform increased the reflection coefficient of the tsunami-vegetation interaction by 34%, while decreasing the transfer coefficient and energy attenuation coefficient by 25% and 13%, respectively. Therefore, the hydraulic characteristics of a tsunami is highly likely to be underestimated if the solitary wave of the approximation theory is applied for the tsunami.