• Title/Summary/Keyword: position correction

Search Result 651, Processing Time 0.022 seconds

Geometric Correction of the NOAA/AVHRR Imagery (NOAA/AVHRR 영상의 기하학적 보정)

  • 서명석;신경섭;박경윤
    • Korean Journal of Remote Sensing
    • /
    • v.6 no.1
    • /
    • pp.25-37
    • /
    • 1990
  • Methods of geometric correction for the Advanced Very High Resolution Radiometer imagery of NOAA satellites were developed and applied to the software for image processing of meteorological satellite data. The software for finding the earth location of each scan position and the software for gridding on original imagery were dedigned. On the assumption of circular orbits and the spherical earth, the methods developed were sufficiently accurate in the purpose of most meteorological data analyses.

A Study on the Design of Digital Controllers with Automatic Calibration (자동 보정형 디지털 제어기 설계에 관한 연구)

  • 나승유;박민상
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.413-416
    • /
    • 1998
  • Sensitivity and calibration considerations are most important in the design and implementation of real control systems. Ideally parameter changes due to various causes should not appreciably affect the system's performances. But all the values of physical components of the plants and controllers as well as the relevant environmental conditions change in time, thus the output performance can be deteriorated during the operating span of the system. Naturally the duty of calibration or the prevention of performance deterioration due to excessive component sensitivity should be provided to the control system. In this paper, we propose a digital controller which has the capability of calibration and gain adjustment as well as the execution of control law. Specifically the problems of gain adjustment and offset calibration in the light source and CdS sensor module for position measurement in a flexible link system are considerably resolved. The parameters of measurement module are prone to change due to environmental brightness conditions resulting in poor steady state performance of the overall control system. Thus a proper method is necessary to provide correction to the changed values of gain and offset in the position measurement module. The proposed controller, whenever necessary, measures the open-loop characteristics, andthen calculates the offset and sensor gain correction values based on the prepared standard measurements. It is applied to the control of a flexible link system with the gain and offset calibration porblems in the light sensor module for position to show the applicability.

  • PDF

SURGICAL CORRECTION OF SEVERE MANDIBULAR PROGNATHISM BY OBWEGESER II AND RIGID INTERNAL FLXATION (심한 하악골 전돌증 환자의 외과적 치험례)

  • Lee, Geon-Ho;Kwon, Dae-Geon;Jang, Do-Geon;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • Obwegeser II method and Rigid fixation conserving the condylar position has been performed on 5 patients with severe mandibular prognathism, and we obtained the result after the follow up study follows. 1. Obwegeser II method is considered to move the distal segment passively when surgical correction of severe open bite correction and large amount of set back above 15mm is needed. 2. In one case that has more change of condylar position after operation, documented immediate post-operative relapse have been occurred 3. In the others that have adequate control of condylar position, passive set back and firm skeletal fixation, more functional and esthetic improvement and more post-operative stability has been achieved

  • PDF

Zero Torque Control of Switched Reluctance Motor for Integral Charging (충전기 겸용 스위치드 릴럭턴스 전동기의 제로토크제어)

  • Rashidi, A.;Namazi, M.M;Saghaian, S.M.;Lee, D.H.;Ahn, J.W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.328-338
    • /
    • 2017
  • In this paper, a zero torque control scheme adopting current sharing function (CSF) used in integrated Switched Reluctance Motor (SRM) drive with DC battery charger is proposed. The proposed control scheme is able to achieve the keeping position (KP), zero torque (ZT) and power factor correction (PFC) at the same time with a simple novel current sharing function algorithm. The proposed CSF makes the proper reference for each phase windings of SRM to satisfy the total charging current of the battery with zero torque output to hold still position with power factor correction, and the copper loss minimization during of battery charging is also achieved during this process. Based on these, CSFs can be used without any recalculation of the optimal current at every sampling time. In this proposed integrated battery charger system, the cost effective, volume and weight reduction and power enlargement is realized by function multiplexing of the motor winding and asymmetric SR converter. By using the phase winding as large inductors for charging process, and taking the asymmetric SR converter as an interleaved converter with boost mode operation, the EV can be charged effectively and successfully with minimum integral system. In this integral system, there is a position sliding mode controller used to overcome any uncertainty such as mutual inductance or DC offset current sensor. Power factor correction and voltage adaption are obtained with three-phase buck type converter (or current source rectifier) that is cascaded with conventional SRM, one for wide input and output voltage range. The practicability is validated by the simulation and experimental results by using a laboratory 3-hp SRM setup based on TI TMS320F28335 platform.

Correction of Fluoroscopic Image for Nucleoplasty in Lumbar Disc (요추디스크 수핵감압술을 위한 투시영상의 교정)

  • Yun, Young Woo;Kang, Se Sik;Choi, Seok Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.359-365
    • /
    • 2016
  • Fluoroscopy is performed when tissue or organ in the human body is examined, and it is used for diagnosis and procedure in back ailments. With regard to fluoroscopy equipment, distortion occurs on the peripheral part of fluoroscopic image rather than on its central part. This study measured distortion factors of vertical spacing ratio and distortion factor of diagonal spacing ratio before and after correction by applying a correction algorithm. According to measuring the vertical spacing ratio, post-correction standard deviation decreased by 0.04 in comparison with pre-correction one. Also measuring the diagonal spacing ratio, post-correction standard deviation decreased by 0.06 in comparison with pre-correction one. Consequently, the distortion of fluoroscopic image decreased after correction. A decrease in the distortion of image through the application of correction algorithm and the improvement of performance will be helpful in finding a correct position of lumbar puncture in nucleoplasty to treat lumbar disc herniation in the future.

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

Study on Error Correction of Impact Sound Position Estimation Using Ray Tracing (음선 추적을 이용한 폭발음 위치추정 오차 보정에 대한 연구)

  • Choi, Donghun;Go, Yeong-Ju;Lee, Jaehyung;Na, Taeheum;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.89-96
    • /
    • 2016
  • TDOA(time delay of arrival) position estimate from acoustic measurement of artillery shell impact is studied in order to develop a targeting evaluation system. Impact position is calculated from the intersections of hyperbolic estimates based on the least square Taylor series method. The mathematical process of Taylor series estimation is known to be robust. However, the concern lays with the accuracy because it is sensitive to the bias caused by the randomness of measurement situation. The measurement error typically occurs from the distortion of waveform, change of travelling path, and sensor position error. For outdoor measurement, a consideration should be made on the atmospheric condition such as temperature and wind which can possibly change the trajectories of rays of sound. It produces wrong propagation time events accordingly. Ray tracing and optimization techniques are introduced in this study to minimize the bias induced by the ray of sound. The numerical simulation shows that the atmospheric correction improves the estimation accuracy.

Blind QR Code Steganographic Approach Based upon Error Correction Capability

  • Chiang, Yin-Jen;Lin, Pei-Yu;Wang, Ran-Zan;Chen, Yi-Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.10
    • /
    • pp.2527-2543
    • /
    • 2013
  • A novel steganographic QR code algorithm, which not only coveys the secret into the widely-used QR barcode but also preserves the readability of QR content and the capability of error correction, is presented in this article. Different from the conventional applications for QR barcode, the designed algorithm conceals the secret into the QR modules directly by exploiting the error correction capability. General browsers can read the QR content from the QR code via barcode readers; however, only the authorized receiver can further reveal the secret from the QR code directly. The new mechanism can convey a larger secret payload along with adjustment of the QR version and error correction level. Moreover, the blind property allows the receiver to reveal the secret without the knowledge of the embedded position of modules. Experimental results demonstrate that the new algorithm is secure, efficient and feasible for the low-power QR readers and mobile devices.