• Title/Summary/Keyword: portable device

Search Result 592, Processing Time 0.034 seconds

Study on the Smart 1RM System Development and Effect Verification for Health Improvement and Management of National Healthcare (국민 건강관리 및 체력증진을 위한 스마트 1RM 시스템 개발 및 효과 검증에 관한 연구)

  • Woo, Kyung-Min;Shin, Mi-Yeon;Yu, Chang-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.12 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, we developed a smart 1RM system for national health management and physical fitness, which enables quantitative 1RM measurement in various types of exercise using digital pulley technology, and to test the effect on training by using it. We developed the smart 1RM system, which is composed of portable muscle strength measuring device, Bluetooth communication based mobile phone data transmission and circuit diagram, and height adjustable system body. We recruited the 30 participants with 20th aged and divided into training and non-performing groups with 15 participants randomly. The participants performed 5 sets of elbow, lumbar, knee extension / flexion 10 times using smart 1RM system and the experimental period was 3 days a week for a total of 8 weeks. The experimental results showed that the maximum strength of the elbow, lumbar, and knee joints was significantly improved before and after maximal muscle strength training in the training group. Oxygen intakes during 1RM exercise mode showed 10.91% than endurance. To verify the validity of the smart 1RM maximal strength data, the reliability was 0.895 (* p <0.00). This study can be applied to the early rehabilitation treatment of the elderly and rehabilitation patients more quantitatively using the national health care.

The Utility of Emergency Ultrasound for Diagnosing Wrist and Ankle Injuries (손목 관절과 발목 관절 손상 환자의 진단에 있어 응급 초음파의 유용성)

  • Lee, Sung Sil;Kim, Dong Un;Park, Deuk Hyun;Cho, Hyun Young;Ahn, Seung Jun;Kho, Chan Young;Shin, Tae Yong;Kim, Young Sik;Ha, Young Rock
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • Purpose: Ultrasound is of proven accuracy in abdominal and thoracic trauma and may be useful for diagnosing extremity injury in situations where radiography is not available, such as disasters and military and space applications. However, the diagnosis of fractures is suggested by history and physical examination and is typically confirmed with radiography. As a alternative to radiography, we prospectively evaluated the utility of extremity ultrasound performed by trained residents of emergency medicine (EM) one patient with wrist and ankle extremity injuries. Methods: Initially, residents of EM performed physical examinations for fractures. The emergency ultrasound (EM US) was performed by trained residents, who used a portable ultrasound device with a 10- to 5-MHz linear transducer, on suspected patients before radiography examination. The results of emergency ultrasound and radiography and the final diagnosis were recorded, and correlation among them were determined by using Kappa s test Results: Thirty-nine patients were enrolled in our study. The average age was $36.6\;{\pm}\;19.3$ years. There were radius Fx. (n=21), radius-ulna Fx. (n=1), ulna Fx. (n=1), and contusion (n=2) injuries among the wrist injury and lat.-med. malleolar Fx. (n=13), lat. malleolar Fx. (n=6), and med. malleolar Fx. (n=3) injuries among the ankle injury. Comparing EM US with radiography, we found the sensitivity, specificity, positive predictive value, and negative predictive value of EM US for Fx. diagnosis to be 100%, 66.7%, 97.3%, 100% and those of radiography to be 97.2%, 100%, 100%, and 75%, respectively. Kappa s test for a correlation between the Fx. diagnosis of EM US and the final diagnosis of Fx was performed, and Kappa's value was 0.787 (P = 0.004).Conclusion: EM US for Fx. can be performed quickly and accurately by EM residents with excellent accuracy in remote locations such as disaster areas and in military and aerospace applications. EM US was as useful as radiography in our study and had a high correlation to the final diagnosis of Fx. Therefore, ultrasound should performed on patients with extremity injury to determine whether extremity evaluation should be added to the FAST (focused abdominal sonography trauma) examination.

Design and Implementation Stereo Camera based Twin Camera Module System (스테레오 카메라 기반 트윈 카메라 모듈 시스템 설계 및 구현)

  • Kim, Tae-Yeun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.537-546
    • /
    • 2019
  • The paper actualizes the twin camera module system that is portable and very useful for the production of 3D contents. The suggested twin camera module system is a system to be able to display the 3D image after converting the inputted image from 2D stereo camera. To evaluate the performance of the twin camera module suggested in this paper, I assessed the correction of Rotation and Tilt created depending on the visual difference between the left and right stereoscopic image shot by the left and right lenses by using the Test Platform. In addition, I verified the efficiency of the twin camera module system through verifying Depth Error of 3D stereoscopic image by means of Scale Invariant Feature Transform(SIFT) algorithm. I think that if the user utilizes the suggested twin camera module system in displaying the image to the external after converting the shot image into the 3D stereoscopic image and the preparation image, it is possible to display the image in a matched way with an output device fit respectively for different 3D image production methods and if the user utilizes the system in displaying the created image in the form of the 3D stereoscopic image and the preparation image via different channels, it is possible to produce 3D image contents easily and conveniently with applying to lots of products.

Design of Bias Circuit for Measuring the Multi-channel ISFET (다채널 ISFET 측정용 단일 바이어스 회로의 설계)

  • Cho, Byung-Woog;Kim, Young-Jin;Kim, Chang-Soo;Choi, Pyung;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 1998
  • Multi-channel sensors can be used to increase the reliability and remove the random iloise in ion-sensitive field effect transistors(ISFETs). Multi-channel sensors is also an essential step toward potential fabrication of sensors for several ionic species in one device. However, when the multi-channel sensors are separately biased, the biasing problems become difficult, that is to say, the bias circuit is needed as many sensors. In this work, a circuit for biasing the four pH-ISFETs in null-balance method, where bias voltages are switched, was proposed. The proposed concept is need only one bias circuit for the four sensors. Therefore it has advantages of smaller size and lower power consumption than the case that all sensors are separately biased at a time. The proposed circuit was tested with discrete devices and its performance was investigated. In the recent trend, sensor systems are implemented as portable systems. So the verified measurement circuit was integrated by using the CMOS circuit. Fortunately, ISFET fabrication process can be compatible with CMOS process. Full circuit has a mask area of $660{\mu}m{\times}500{\mu}m$. In the future, this step will be used for developing the smart sensor system with ISFET.

  • PDF

Study on Physical Properties of Domestic Species II: Sorption, Thermal, Electrical and Acoustic Properties of Pinus koraiensis and Larix kaempferi (국산재의 응용물성연구II: 잣나무 낙엽송의 수분흡착성 및 열적·전기적·음향적 성질)

  • Byeon, Hee-Seop;Lee, Won-Hee;Park, Byung-Soo;Chong, Sung-Ho;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • A series of the studies on the applied physical properties of domestic species have been conducted last three years. Pinus koraiensis and Larix kaempferi were two of the three species examined for the first year. Because the same apparatus and experimental procedures were used for all species, their results can be easily comparable. The experiments for sorption property were conducted with 20- and 80-mesh wood powder and resulted in their EMCs and sorption isotherms at various RH conditions. The thermal conductivity and diffusivity, and electric resistance and volumetric electric resistivity were measured with a thermal-wire device and a high electric resistance meter. The differences in the thermal and electric properties between quarter- and flat-sawn specimens were observed, which were partially attributed to their anatomical differences. An acoustic measurement system was used to evaluate dynamic MOE and internal friction. This paper provides the useful fundamental data for designing a wood structure, correcting a portable resistance-type moisture meter, and acoustic properties of wood.

LED Beam Shaping and Fabrication of Optical Components for LED-Based Fingerprint Imager (LED 빔조형에 의한 초소형 이미징 장치의 제조 기술)

  • Joo, Jae-Young;Song, Sang-Bin;Park, Sun-Sub;Lee, Sun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1189-1193
    • /
    • 2012
  • The Miniaturized Fingerprint Imager (MFI) is a slim optical mouse that can be used as an input device for application to wireless portable personnel communication devices such as smartphones. In this study, we have fabricated key optical components of an MFI, including the illumination optical components and imaging lens. An LED beam-shaping lens consisting of an aspheric lens and a Fresnel facet was successfully machined using a diamond turning machine (DTM). A customized V-shaped groove for beam path banding was fabricated by the bulk micromachining of silicon that was coated with aluminum using the shadow effect in thermal evaporation. The imaging lens and arrayed multilevel Fresnel lenses were fabricated by electron beam lithography and FAB etching, respectively. The proposed optical components are extremely compact and have high optical efficiency; therefore, they are applicable to ultraslim optical systems.

A Study on Development of ECS for Severly Handicaped (중증 장애인을 위한 생활환경 제어장치개발에 관한 연구)

  • 임동철;이행세;홍석교;이일영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.427-434
    • /
    • 2003
  • In this paper, we present a speech-based Environmental Control System(ECS) and its application. In the concrete, an ECS using the speech recognition and an portable wheelchair lift control system with the speech synthesis are developed through the simulation and the embodiment. The developed system apply to quadriplegic man and we evaluate the result of physical effect and of mental effect. Speech recognition system is constructed by real time modules using HMM model. For the clinical application of the device, we investigate the result applied to 54-years old quadriplegic man during a week through the questionnaires of Beck Depression Inventory and of Activity Pattern Indicator. Also the motor drive control system of potable wheelchair lift is implemented and the mechanical durability is tested by structural analysis. Speech recognition rate results in over 95% through the experiment. The result of the questionnaires shows higher satisfaction and lower nursing loads. In addition, the depression tendency of the subject were decreased. The potable wheelchair lift shows good fatigue life-cycle as the material supporting the upper wheelchair and shows the centroid mobility of safety. In this paper we present an example of ECS which consists of real-time speech recognition system and potable wheelchair lift. Also the experiments shows needs of the ECS for korean environments. This study will be the base of a commercial use.

I-V Characteristics of a Methanol Sensor for Direct Methanol fUel Cell(DMFC) as a Function of Deposited Platinum(Pt) Thickness (직접 메탄올 연료전지용 메탄올 센서의 백금 두께의 변화에 따른 전류-전압 특성 변화)

  • Yang, Jin-Seok;Kim, Seong-Il;Kim, Chun-Keun;Park, Jung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • The direct methanol fuel cell (DMFC) is a promising power source for portable applications due to many advantages such as simple construction, compact design, high energy density, and relatively high energy-conversion efficiency. In this work, an electrochemical methanol sensor for monitoring the methanol concentration in direct methanol fuel cells was fabricated using a thin composite nafion membrane as the electrolyte. We have analyzed the I-V characteristic of the fabricated methanol sensor as a function of methanol concentration, catalyst electrode and platinum(Pt) thickness. The fabricated sensor was analyzed by I-V measurement with various methanol concentration. When we measured the sensor characteristics with 10nm Pt and at 1V, the current value was $1.30{\times}10^{-6}A,\;1.96{\times}10^{-6}A\;and\;2.80{\times}10^{-6} A$ for three methanol concentration of 1M, 2M and 3M, respectively. When the methanol concentration was fixed at 2M, the current value of the fabricated device with Pt layers of 5, 10 and 15 nm thickness was $3.06{\times}10^{-6}A,\;1.96{\times}10^{-6}A\;and\;1.00{\times}10^{-6}A$, respectively. These results lead us to the conclusion that when the methanol concentration increases, the output current increases and when the catalyst electrode become thinner, the current increase more. It showed that, the thinner the catalyst electrode, the more electrochemistry become activation.

  • PDF

A Study on Implementation Integrated Operation & Management System for Intermodal Connectivity Center (복합환승센터 통합운영시스템 구축방안에 관한 연구)

  • Kim, Sung-Eun;Lim, Jung-Sil;Moon, Young-Jun;Oh, Jae-Hak;Lee, Won-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.24-35
    • /
    • 2011
  • This paper demonstrates a methodology of integrated operation and management system for intermodal connectivity center (ICC), which is planning to be build up as a large scale public transit facilities for green growth strategy by the national government. The ICC needs to be capable of providing the integrated location based information for the public transit users in terms of collaborating a variety of transit modes and complex facility in a large scale center. Recently, the upcoming information and communication technologies enable to come up with real time information provision on nomadic and portable devices, i.e. smart phones and/or tablet PCs, as what the users actually need to get on demand. In order to provide the public transit users in ICC with the integrated information on their smart phones for example, the integrated operation and management system plays a key role to collect the data utilizing the wireless communication with real time location tracking and to manage them to be effective and operational sources for applicable personalized services. Thus, this paper defines a type of services, subsystems, and relevant technologies for the system integration so called a "Smart Garatagi Service" and shows a filed test demonstration case in the existing airport terminal, Gimpo Domestic.

A Proposal of Flow Limit for Soils at Zero Undrained Shear Strength (흙의 비배수전단강도가 0이 되는 함수비인 흐름한계의 제안)

  • Park, Sung-Sik;Nong, Zhenzhen
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.73-84
    • /
    • 2013
  • When a slope failure or a debris flow occurs, a shear strength on failure plane becomes nearly zero and soil begins to flow like a non-cohesive liquid. A consistency of cohesive soils changes as a water content increases. Even a cohesive soil existing at liquid limit state has a small amount of shear strength. In this study, a water content, at which a shear strength of cohesive soils is zero and then cohesive soils will start to flow, was proposed. Three types of clays (kaolinite, bentonite and kaolinite (50%)+bentonite (50%)) were mixed with three different solutions (distilled water, sea water and microbial solution) at liquid limit state and then their water contents were increased step by step. Then, their undrained shear strength was measured using a portable vane shear device called Torvane. The ranges of undrained shear strength at liquid and plastic limits are 3.6-9.2 kPa and 24-45 kPa, respectively. On the other hand, the water content that corresponds to the value of the undrained shear strength changing most rapidly is called flow water content. The flow limit refers to the water content when undrained shear strength of cohesive soils is zero. In order to investigate the relationship between liquid limit and flow limit, the cohesive index was defined as a value of the difference between flow limit and liquid limit. The new plasticity index was defined as the value of difference between flow limit and plastic limit. The new liquidity index was also defined using flow limit. The values of flow limit are 1.5-2 times higher than those of liquid limit. At the same time, the values of new plasticity index are 2-5.5 times higher than those of original plasticity index.