• Title/Summary/Keyword: portable device

검색결과 589건 처리시간 0.024초

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E4호
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

휴대용 부탄 가스 레인지의 안전성에 관한 실험적 연구 (Experimental Study on the Safety of Portable Butane Gas Range)

  • 금국빈;김도현;금성민;이창언;김영구
    • 한국연소학회지
    • /
    • 제22권2호
    • /
    • pp.50-56
    • /
    • 2017
  • This study was conducted an experiment for the thermal flow mechanism of the surrounding butane gas can and pressure change in butane can with oversized cookware. And numerical analysis was performed to analyze the process of heat transfer around butane can. Effect of radiant heat from small size cookware is very small. Thus small size cookware does not have a significant impact on the butane gas range safety. But radiant heat of oversized cookware is larger than small size cookware. Therefore it gives an adverse effect on the butane can. And when internal pressure of butane can is greater than about 406.8~447.2 kPa, a safety device of portable butane gas range were working. The causes of safety device working is because of trivet height. Trivet height is lowered, the radiant heat is increased. This radiant heat is to raise pressure of inside butane can. Experimental and numerical analysis results, the lower thermal conductivity of the cookware is greater the effects of radiant heat.

휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발 (Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device)

  • 이은미;홍주현;차은종;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

미아 방지용 스마트 디바이스 구현에 관한 연구 (Smart device research for the prevention of missing child)

  • 안종찬;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.437-440
    • /
    • 2007
  • 최근 임베디드 시스템 디바이스 분야가 많은 발전을 이루었다. MP3, 디지털 시계같은 휴대형 디바이스에서부터 공장 제어기계난 핵발전소 제어 시스템과 같은 큰 규모의 시스템까지 그 범위가 광대하다. 본 논문은 임베디드 휴대형 장치를 구현하는 데 초점을 두었으며 이를 이용하여 아파트 공공단지 내 유아 유괴 방지 시스템에 적용시켜보았다. ARM9 core를 적용한 s3c2440을 이용한 임베디드 하드웨어 플랫폼으로 구현하였고 이 위에 WindowsCE OS를 사용하여 영상의 입력과 처리 그리고 전송의 멀티태스킹 작업을 가능하게 하였다. 그 외 GPS정보를 이용한 위치 추적, 카메라와 마이크의 실시간 영상 소리 데이터를 이용한 사용자의 상태확인 등의 다른 어플리케이션과 서비스를 구현할 수 있도록 하였다. 본 논문은 스마트 디바이스에서 받은 영상을 WLAN으로 호스트PC에 전송을 하는 시스템에 초점을 맞추었다.

  • PDF

Development of a Tele-Rehabilitation System for Outcome Evaluation of Physical Therapy

  • Park, Hyung-Soon;Lee, Jeong-Wan
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.179-186
    • /
    • 2008
  • This paper presents a portable tele-assessment system designed for remote evaluation of the hypertonic elbow joint of neurologically impaired patients. A patient's upper limb was securely strapped to a portable limb-stretching device which is connected through Internet to a portable haptic device by which a clinician remotely moved the patient's elbow joint and felt the resistance from the patient. Elbow flexion angle and joint torques were measured from both master and slave devices and bilaterally fed back to their counterparts. In order to overcome problems associated with the network latency, two different tele-operation schemes were proposed depending on relative speed of tasks compared to the amount of time delay. For slow movement tasks, the bilateral tele-operation was achieved in real-time by designing control architectures after causality analysis. For fast movement tasks, we used a semi-real-time tele-operation scheme which provided the clinicians with stable and transparent feeling. The tele-assessment system was verified experimentally on patients with stroke. The devices were made portable and low cost, which makes it potentially more accessible to patients in remote areas.

인시투 가스 측정이 가능한 경제적 가스 챔버 구현 및 센서 전압에 따른 가스 응답 특성 분석 (Economical Gas Chamber for In-situ Gas Measurement and Analysis of Gas Response Characteristics according to Sensor Voltage)

  • 최연석;이인환
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.1-8
    • /
    • 2019
  • Breath analysis using a portable device is better than the classical breath analysis system in terms of installation and operation. There is an increasing need to develop cost-effective equipment for testing gas sensors from the viewpoint of functionalities that can be applied applicable to portable devices. In the present study, an economical gas chamber for in-situ gas measurement is implemented with a single gas chamber without using expensive gas storage and control equipment; the gas response characteristics are analyzed using the above-described chamber. The main features of the implemented gas chamber are simple injection procedure, improved gas diffusion, easy measurement and cleaning, support for low-power mode measurement function for portable devices, and open source platform. Moreover, an analysis of gas response characteristics based on changes in sensor voltage show that the sensitivity and 90% response time are affected by the sensor voltage. Furthermore, the sensitivity graph has an inflection point in a specific range. The gas sensor applied in this study showed fast response speed and high sensitivity for sensor voltages of 3.0-3.5 V, regardless of the concentration of acetone gas, the target gas used in this study.

휴대장치용 새로운 자기 스프링 액추에이터의 해석 (Analysis of Novel Magnetic-Spring Actuators for Portable Units)

  • 한인환
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1942-1949
    • /
    • 2004
  • SLA(Scanned Linear Array) is a portable display unit for implementing next-generation virtual realities, utilizes a design that light generated by a line of LEDs is reflected from the rapidly oscillating mirror to generate a raster display. Reaction forces generated by the motions of the mirror and counter-balance mass cancel each other at the device base, reducing vibration. Metal leaf springs have been extensively applied in such portable units. Magnetic springs have been developed and adopted that can replace the metal spring and can avoid many disadvantages of metal springs. We model and analyze the dynamics of the structure with magnetic springs and present the simulation and experimental analysis results, which can be utilized for identifying and eliminating possible problem sources in removing shaking forces and moments, and oscillating the mirror at the required amplitude and frequency. Finally, we present the improved novel magnetic actuator model which can be applied in portable display units.

자가발전활용을 위한 마찰전기 나노발전소자의 제작 (Fabrication of triboelectric nanogenerator for self-sufficient power source application)

  • 신소윤;김상재;발라스브라마니안 사라판구말
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.589-590
    • /
    • 2013
  • The fast development of electronic devices towards wireless, portable and multi-functionality desperately needs the self-powered and low maintenance power sources. The possibility to coupling the nanogenerator to wearable and portable electronic device facilitates the self powered device with independent and self sustained power source. Nanogenerator has ability to convert the low frequency mechanical vibration to electrical energy which is utilized to drive the electronic device [1]. The self powered power source has the ability to generate the power from environment and human activity has attracted much interest because of place and time independent. The human body motion based energy harvesting has created huge impact for future self powered electronics device applications. The power generated from the human body motion is enough to operate the future electronic devices. The energy harvesting from human body motion based on triboelectric effect has simple, cost-effective method [2, 3] and meet the required power density of devices. However, its output is still insufficient to driving electronic devices in continues manner so new technology and new device architecture required to meet required power. In the present work, we have fabricated the triboelectric nanogenerator using PDMS polymer. We have studied detail about the power output of the device with respect to different polymer thickness and varied separation distance.

  • PDF

휴대형 심전도 모니터링 장치에서의 2가지 호흡 검출 알고리즘 (Two algorithms for detecting respiratory rate from portable patient monitoring device)

  • 김종명;홍주현;김남진;차은종;이태수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.36-38
    • /
    • 2006
  • In this study, two algorithms for detecting respiratory rate from Portable ECG device were presented. The first algorithms counts the number of ECG samples between R-R peaks, which varies according to respiratory states of patients, such as, exhalation and inhalation. The second algorithms detects the rate by measuring the size of R wave, which also varies according to the respiratory status of patient. These two algorithms were programmed to the laboratory developed ECG device and their usefulness was verified in laboratory environment.

  • PDF