Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

화강암의 속도 분석과 풍화도 산정에 미치는 영향 (Velocity analysis of various granite and its impact on determination of weathering)

  • 이재성;김영석
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.201-206
    • /
    • 2008
  • 석조문화재의 풍화도의 산정은 문화재의 진단 및 보존에 매우 중요한 부분으로 많은 경우 풍화암의 속도와 신선암의 속도의 차이를 이용한 경험식에 의존하고 있다. 본연구에서는 국내의 석조문화재를 구성하고 있는 대표적 지역인 익산, 거창, 원주, 괴산, 충주에서 획득한 신선한 화강암을 대상으로 실험실 및 현장측정 장비를 이용해 속도를 측정, 비교하고 이것이 풍화지수산정에 미치는 영향을 알아보고자 한다. PUNDIT을 사용하는 현장측정의 경우 휴대가 간편하나 측정속도의 불확실성이 높을 가능성이 있기 때문에 실험실에서 암삼축 시험기를 이용한 측정과 비교하였다. 이 두 자료를 비교하여 현장측정의 상대적 정확도를 비교, 분석할 수 있었고 이 차이는 암석의 풍화도 산정에는 크게 영향을 미치지 않는 것으로 나타났다. 하지만 일반적으로 풍화도 산정에 쓰이고 있는 신선암의 속도는 5000m/s를 사용하고 있으나, 5개의 지역에서 선정된 신선한 화강암의 속도는 3200에서 4400m/s까지 다양하게 나타났다. 따라서 이러한 차이를 무시하고 풍화도를 산정하는 경우 실제 신선암의 속도를 사용하는 경우에 비하여 그 풍화도가 많게는 2단계 이상 높게 평가되었으며 이는 문화재의 진단 및 보존에 매우 큰 영향을 미칠 것으로 생각된다.

  • PDF

LabVIEW를 이용한 자동차 발전기 전압 계측시스템 (Measurement System for Vehicle Electric Power using LabVIEW)

  • 소순선;양수진;이성철
    • 한국산학기술학회논문지
    • /
    • 제15권10호
    • /
    • pp.5899-5905
    • /
    • 2014
  • 본 차량에 장착되는 전자장비의 증가로 인해 교류발전기와 배터리를 이용하여 전기에너지를 공급하고 있으며, 자동차 교류발전기의 수명단축은 교류발전기를 구성하고 있는 부속품들 중에 수명이 한정적이거나, 어떠한 조건에서 사용되느냐에 따라 수명에 영향을 끼치게 된다. 이러한 수명단축의 원인들을 파악하기 위해서는 교류발전기의 전압을 측정하여 분석하는 시스템이 필요하다. 따라서 본 연구에서는 자동차 교류발전기의 수명과 성능을 유지하기 위한 점검 및 정비에 필요한 정밀한 계측 시스템을 개발하였다. PC기반의 모니터링 시스템과 측정데이터를 저장할 수 있는 시스템을 설계하고, LabVIEW SW를 이용하여 계측 시스템을 구동하기 위한 프로그램을 개발하였다. 차동 OP-AMP회로를 이용하여 교류발전기의 발전전압, 여자전압, 램프전압, 배터리 전압, 크랭크 각 센서에 의한 엔진 회전수를 NI DAQ를 통하여 전압을 측정하고 LabVIEW 프로그램을 이용하여 측정데이터를 분석하였다. 기존에 개별적으로 이루어졌던 측정을 5개 채널까지 복합적이고 이동성이 용이한 측정이 가능하였고, 실시간으로 모니터링하며 분석하기 때문에 이상동작 유무 및 고장상태를 예측하기 위한 자료로 활용될 수 있을 것으로 기대된다.

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

스펙트로레디오메터를 이용한 벼 생장시기의 분광반사 특성 변화 분석 (Analysis of Spectral Reflectance Characteristic Change during Growing Status of Rice Plants using Spectroradiometer)

  • 장세진;서애숙;김판기;윤진일
    • 한국지리정보학회지
    • /
    • 제3권3호
    • /
    • pp.12-19
    • /
    • 2000
  • 관심있는 농작물의 반사 특성에 대한 지식은 우리에게 농업 분야에서의 원격탐사 활용에 대한 가능성을 제공한다. 본 연구에서는 일품벼의 이앙기에서 수확기까지의 성장 단계에 따른 반사 특성을 측정 및 분석하였다. 벼는 1999년 5월 20일에 경기도 수원시 서둔동 수원기상대($37^{\circ}$16' N, $126^{\circ}$59' E, 39m Alt.) 뒤에 위치한 3개의 실험 포장에 이앙되었다. 반사 특성 측정은 구름과 바람이 없는 맑은 날을 선택하여 300nm에서 1100nm까지 관측할 수 있는 휴대용 스펙트로레디오메터(Portable spectroradiometer, Li-1800, 미국 Li Cor Inc.)를 사용하였고 관측 시간은 태양 고도 변화에 따른 반사율의 변화를 최소화하기 위하여 태양 고도 변화가 가장 적은 오전 11시에서 오후 1시까지 수행하였다. 관측 높이는 벼 군락으로부터 30cm였고 측정 회수는 1일 3개 포장에 대해 수직 방향으로 각각 3회 관측하였다. 결과적으로, 벼의 경우 가시 영역의 평균 반사율이 청색 영역(400nm~498nm)에서 약 2.34%~2.55%, 녹색 영역(500nm~598nm)에서 약 5.05%~6.01% 그리고 적색 영역(600nm~698nm)에서 약 4.21%~5.24%이며, 벼의 성장 단계에 따라 가시 영역의 경우는 반사율이 감소함을 알 수 있었다. 또한 근적외 영역의 경우는 관측 결과에 따라 두 가지 경우로 나누어 분석을 하였는데, 첫 번째는 700nm~800nm까지 파장의 증가에 따라 반사율이 급격히 증가하는 영역과 800nm~1100nm까지 파장에 따라 반사율이 거의 일정한 영역이다. 이 영역들의 평균 반사율은 700nm~800nm에서 약 22.3%~23.0%, 800nm~1100nm에서는 약 29.4%~33.1%이다. 특히 이 영역은 8월 23일까지 벼의 성장에 따라 반사율이 증가하였으며, 그 이후에는 감소하는 경향을 나타내었다.