• Title/Summary/Keyword: portable ECG

Search Result 74, Processing Time 0.029 seconds

Adaptive Filter Design for Eliminating Baseline Wandering Noise of Electrocardiogram (심전도 기저선 흔들림 잡음 제거를 위한 적응형 필터 설계)

  • Choi, Chul-Hyung;Rahman, MD Saifur;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • The Journal of Korean Institute of Information Technology
    • /
    • v.15 no.12
    • /
    • pp.157-164
    • /
    • 2017
  • Mobile ECG signal measurement is a technique to measure small signals of several mV, and many studies have been conducted to remove noise including wandering scheme. Removal of the equipotential line noise caused by shaking or movement of the electrode cable is one of the core research contents for the electrocardiogram measurement. In this study, we proposed a modified step-size of combined NLMS(normalized least squares) and DLMS(delayed least squares) adaptive filter to eliminate baseline noise from ECG signals. The proposed method mainly adjusts initial filter step-size to reduce distortion of original ECG signals characteristic after eliminating baseline noise. The modified filter step-size is scaled by filter order size and distortion minimization factor. This method is suitable for portable ECG device with a small processor and less power consumption. This technique also decreases computation time which is essential for real-time filtering. The proposed filter also increase the signal to noise ratio (SNR) compared to conventional NLMS filter.

Implementation of the ECG and Plethysmograph Monitoring System for Home Healthcare (홈 헬스케어용 심전도 및 맥파 측정시스템 구현)

  • Hwang, Jun-Heum;Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.662-665
    • /
    • 2008
  • 본 연구에서는 기존 병원중심의 생체신호모니터링을 가정 내에서 보다 편리하게 수행하여 일상생활중 지속적인 건강상태를 모니터링하고 계측된 생체신호를 웹을 통해 병원이나 전문가가 실시간으로 모니터링 할 수 있는 생체신호 모니터링 시스템을 구현하였다. 구현한 시스템은 범용적인 건강모니터링에 활용할 수 있는 생체신호인 심전도, 맥파를 측정대상으로 하였다. 심전도와 맥파의 계측을 위하여 신호 측정부를 구성하였고, 신호측정부로부터 검출된 신호를 PC기반의 신호모니터링 프로그램으로 전송하기 위하여 마이크로프로세서를 이용한 신호변환 및 시스템 제어부를 구성하였다. 계측된 데이터는 시스템 자체에서 그래픽 LCD를 이용하여 디스플레이가 가능하도록 구성하였으며, 블루투스 통신을 통해 PC와의 무선통신이 가능하도록 시스템을 구성하였다. 또한 PC기반의 실시간 모니터링 프로그램을 구현하여 데이터의 디스플레이 및 저장이 가능하도록 하였으며, 더 나아가 원격지에서의 신호모니터링이 가능하도록 시스템을 구현하였다.

  • PDF

R Wave Detection and Advanced Arrhythmia Classification Method through QRS Pattern Considering Complexity in Smart Healthcare Environments (스마트 헬스케어 환경에서 복잡도를 고려한 R파 검출 및 QRS 패턴을 통한 향상된 부정맥 분류 방법)

  • Cho, Iksung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • With the increased attention about healthcare and management of heart diseases, smart healthcare services and related devices have been actively developed recently. R wave is the largest representative signal among ECG signals. R wave detection is very important because it detects QRS pattern and classifies arrhythmia. Several R wave detection algorithms have been proposed with different features, but the remaining problem is their implementation in low-cost portable platforms for real-time applications. In this paper, we propose R wave detection based on optimal threshold and arrhythmia classification through QRS pattern considering complexity in smart healthcare environments. For this purpose, we detected R wave from noise-free ECG signal through the preprocessing method. Also, we classify premature ventricular contraction arrhythmia in realtime through QRS pattern. The performance of R wave detection and premature ventricular contraction arrhythmia classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30 premature ventricular contraction. The achieved scores indicate the average of 98.72% in R wave detection and the rate of 94.28% in PVC classification.

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

A Study on the Seamless Monitoring over the Wireless LAN and the Public Cellular Network for a Portable Patient Monitoring System

  • Kim Woo-Shik;Cho Hyang-Duck
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.14-21
    • /
    • 2006
  • As information technologies are developing, the improvement of the quality of life becomes worldwide issues. Especially, to improve the quality of life of a patient suffering intermittent diseases, in addition to the some portable equipments for measuring, analyzing, and notifying the status of the patients, methods of communication for seamless transmission of the measured data over to the remote site, such as an emergency center or a hospital, are required. In this paper, we address a seamless transmission of patient monitoring data such as ECG from a moving patient to a remote site, wherever the patient may be. We divide the whole environments into two wireless communication environments: an indoor one based on WLAN and an outdoor one based on CDMA cellular network in which the patient is assumed to move anywhere. We develop algorithms, implement them on a PDA-based hardware platform, and show some of the results for handover between the two environments in addition to the data transmission for each of the two environments.

Study on Development of Portable Incubator (휴대용 인큐베이터의 개발에 관한 연구)

  • Eizad, Amre;Zahra, Falak;Alam, Hamza;Tahir, Hassan;Bangash, Afrasiab Khan;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.1-6
    • /
    • 2019
  • Preterm children require a controlled environment that is as close as possible to that inside the womb. Incubators are well equipped to fulfill this requirement; however, they are cumbersome and expensive, thereby restricting their portability and availability in less developed and rural areas. This research comprises the development and system validation of a portable incubator. The system consists of a collapsible baby enclosure that can be stowed inside the system base when not in use. The enclosure is made from acrylic such that it is easy to clean and allows unhindered visual observation of the occupant while being robust enough to withstand transit conditions. The system can be powered either by a mains supply or a 12-VDC automobile power supply. Additionally, it has an onboard battery to ensure a continuous supply during transit. A Peltier plate controlled using a microcontroller ensures the desired enclosure temperature irrespective of the ambient temperature. Built-in sensor probes can measure the skin temperature, pulse rate, blood oxygenation level, and ECG of the infant and display them on the system screen. The system function is validated by testing its peak power consumption and the heating and cooling performances of the environment control system.

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Development of portable PPG sensor based on smart phone (스마트폰 기반의 휴대용 PPG센서 개발)

  • Kim, Jung-han;Cho, Kyoung-lae;Kim, Sang-yoon;Kang, Sung-in;Bae, Sung-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1009-1011
    • /
    • 2013
  • 최근 U-헬스케어 서비스가 증가함에 따라 예방과 건강증진 등에 관심과 연구가 활발히 이루어지고 있다. 이러한 U-헬스케어에 사용되는 ECG, EMG, PPG EEG등이 스마트폰 기반의 휴대용 장비와 연동된 센서들의 연구 역시 활발히 진행 중이다. 일반적으로 PPG신호는 적외선센서를 이용하여 모세혈관의 혈중 헤모글로빈 농도 변화에 의한 맥파를 측정한다. PPG신호의 잡음을 제거하기 위해 필터를 사용하였다. 필터된 정보를 ADC하여 스마트폰으로 BlueTooth통신을 이용하여 전송한다. 최종적으로 스마트 디바이스에 PPG신호를 그린다. 제작결과 PPG아날로그 신호를 보는 것과 동일하게 스마트 디바이스에 그릴 수 있음을 보였다. 이후 PPG신호를 이용하여 혈관건강도 및 건강예방의 측정의 연구를 계속해서 한다.

  • PDF

8 bit digital signal processing for a portable biosignal monitoring device (휴대용 생체신호 측정시스템의 8비트 디지털신호처리)

  • Shin, Woo-Sik;Ji, Yong-Hwan;Cho, Jung-Hyun;Yoon, Gil-Won
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.893-894
    • /
    • 2006
  • DSP based on a 8 bit microprocessor was studied for ECG and PPG signals. Digital filtering has an advantage of reducing hardware components in system-on-chip design. However, low resolution such as in 8 bit data has much difficulties in DSP. We demonstrated a comparable performance of DSP filtering compared with analog filters.

  • PDF