• Title/Summary/Keyword: portable

Search Result 2,934, Processing Time 0.026 seconds

Performance Characteristics of Portable Resuscitator with the Change of supply Oxygen Pressure (산소 공급압력 변화에 따른 운반형 인공호흡기의 성능 특성 연구)

  • Kim, Young-Soo;Kim, Min-Wook;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Recently, it has been increasing an incidence of heart diseases which is a causative factor in sudden death as Korean population structure has been changing to an aging society. There is growing needs for A portable ventilator which automatically be operated by the pressure of the supplied oxygen and has been spread worldwide. So, we would like to present test methods in accordance with the performance requirements which are important for components of a respirator and a portable ventilator itself. And also would like to find the most suitable condition of internal pressure reduction for the performance requirements according to the changing conditions of internal pressure reduction setting of a portable ventilator.

A Design and Implementation of Efficient Portable Braille Point System for the Visually Impaired Persons (시각 장애인을 위한 효율적인 휴대용 점자시스템의 설계 및 구현)

  • Hwang, Ho-Young;Suh, Hyo-Joong
    • Journal of Internet Computing and Services
    • /
    • v.9 no.5
    • /
    • pp.1-7
    • /
    • 2008
  • This paper explains a new design and Implementation of an efficient portable braille point system for visually Impaired person, The information systems for the visually impaired persons require efficiently designed devices, tools and accessibility to use the devices, and education support. These three conditions are the basic requirements of designing systems for the visually impaired persons, The system proposed in this paper satisfies the above three conditions. The system converts data and web documents between the braille and Hangul using an algorithm stored in a PC, and transfers the converted data to portable devices. And the portable braille device presents the transferred data in an electromagnetic way.

  • PDF

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

Operating characteristics of an air cooling PEMFC for portable application (이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구)

  • Sohn Young-Jun;Park Gu-Gon;Yang Tae-Hyun;Yoon Young-Gi;Lee Won-Yong;Yim Sung-Dae;Kim Chang-Soo
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF

Development of Portable u-Health Monitoring System (휴대형 u-Health 모니터링 시스템 개발)

  • Han, Jung-Soo;Kim, Gui-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.46-53
    • /
    • 2009
  • This study aims to develop a mobile-based portable u-Health Monitoring System which provides a personal medical service on demand by processing patients' data intellectually achieved through sensing technique of non-restriction/non-consciousness oriented and deciding. To do this, we composed a USN-based portable monitoring unit. It is the one, that contains a somatometry sensor which is attached to patient's body and detects bio information, a portable wireless terminal which receives information from the sensor and transmits it to monitor server, and a monitor server which interprets received data through wireless network and processes. Also, it tries to develop a non-restriction /non-consciousness oriented sensing technique which is related to glycosuria and cardiovascular diseases.

A Study on the Measurement of Texture Depth of Pavement Using Portable Laser Profiler (Portable Laser Profiler를 이용한 도로 포장의 노면조직 깊이 측정 방법 연구)

  • Hong, Seong Jae;Hyun, Tak Jib;Kim, Hyung Bae;Kwon, Oh Sun;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.14 no.6
    • /
    • pp.45-55
    • /
    • 2012
  • PURPOSES : Skid resistance and noise of roads highly depend on the characteristics of pavement texture. Therefore, estimation of texture characteristics may give useful information for the skid resistance and noise of road. Generally, Sand Patch Test is performed in order to estimate MTD(Mean Texture Depth). However, it is time-consuming and needs traffic control. This study aimed to investigate the effectiveness of measurement texture depth using the Portable Laser Profiler that give the MPD(Mean Profile Depth). METHODS : MTD and MPD were collected on the number of expressway sections including Central Inland Test Road sections in Korea. Statistical analysis are performed to establish the relationship between MTD data based on Sand Patch Test and MPD data obtained by the Portable Laser Profiler. RESULTS : Linear relationship MPD and MTD is observed for both of asphalt pavement and concrete pavement such as R-square of 0.51 to 0.58. CONCLUSIONS : Even though, the test method and definition of MPD and MTD are different. EMTD(Estimated Mean Texture Depth) can be obtained by using the correlationship between MPD with MTD.

A Study on Buckling Analysis of Portable Prestressing Device for Pretensioning PSC girders (프리텐션 방식의 PSC 거더 이동식 제작장치의 좌굴해석 연구)

  • Kim, Jong-Suk;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.419-424
    • /
    • 2012
  • This study is a research on the buckling analysis of a portable prestressing device using finite element analysis program, ABAQUS. In order to produce 50m-span PSC girders using pretensioning method, a portable prestressing device has to endure a large jacking force about 10MN. Therefore it shall be safe and stable about the jacking force. In this study, the buckling analysis technique is developed and the buckling analysis of a portable prestressing device is performed using previous studies about the analytical model that the validity of the analytical model was demonstrated by comparing analytical results with experimental results. The stability of the device to produce 10m span PSC girders is investigated.

The Survey for the Maximum Noise Level of Portable Audio Equipments and Its Assessment (휴대용 음향기기 소음실태 및 소음도 평가)

  • Lee, Jaewon;Gu, J.H.;Park, H.G.;Lee, W.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Recently, the impact on hearing induced by using of portable audio equipment have been actively studied. In general, Because they turn the volume up with loud background noise, they may expose to louder noise. In this study, we investigated the maximum noise level of 20 the domestic potable audio equipment and estimated the impact of the hearing induced by portable audio equipment in according to exposure time. As a result, the use of portable audio equipment is assumed to be more three hours when the level of more than 50 % of volume is most likely to affect the hearing.

Portable-size Drone Design Using TRIZ Method (TRIZ 기법을 통한 휴대가 용이한 Drone 설계)

  • Kim, Jong Hyeong;Kim, Hyung-jik;Jung, Jae Nam;Jang, Dong-hee;Kwon, Hyuk-dong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.230-237
    • /
    • 2017
  • Various drones have extended application area very fast. In this paper, we define two contradictions in designing a portable-size drone by using TRIZ technique. The first is a physical contradiction between high rigidity and good portability, and the second is a technical contradiction between high stability and good portability. Through TRIZ technique, six design principles, which guide direction for optimal design, were driven. Consequently, an umbrella mechanism and design criteria were proposed for a portable-size drone. Detail design is verified through finite element method. Test results for the portable-size prototype drone show good performance, and prove its usefulness to be equivalent to a general full-size drone.

Improvement on Pressure Drop Performance of Flow Control Disk in Portable Resuscitator (CFD 해석을 통한 인공호흡기 유량조절디스크의 압력 강하 성능개선)

  • Kim, Young-Soo;Kim, Min-Wook;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • Cases of cardiac arrests due to cardiovascular ailments have increased recently., portable Current portable resuscitators which can be automatically supply oxygen operated by the pressure of supplied oxygen without manual or electronic actuators are now widely used in emergency worldwide. However, reductions in Pressure drop characteristics through the extended use of this type of resuscitator, however, is are not well-known described. This paper describes the reduction in pressure loss drop performance of the various holes in within the flow control disc of with various hole size of the portable resuscitators using on breathing resistance through the CFD simulation, and suggests the an optimum optimal design of the hole shapes for the minimization of alteration in order to minimize this pressure drops.