• Title/Summary/Keyword: poor water quality

Search Result 275, Processing Time 0.025 seconds

Ecological Health Assessments and Water Quality Patterns in Youdeung Stream (유등천에서의 생태학적 건강도 평가 및 수질양상)

  • Lee, Jae-Yon;Jang, Ha-Na;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.341-351
    • /
    • 2005
  • Ecological stream health, based on the index of biological integrity (IBI) , was evaluated at five sampling locations of Youdeung Stream during August-October 2004. For the study, we also analyzed spatial and temporal patterns of conventional water quality over tine period of 1995 ${\sim}$ 2004, using the water chemistry dataset, obtained from the Ministry of Environment, Korea. The water quality parameters used here were conductivity, total suspended solids (TSS), biochemical oxygen demand $(BOD_5)$, chemical oxygen demand $(COD_{mn})$, total nitrogen (TN), and total phosphorus (TP). The multi-metric model values averaged 27.8 in the stream and ranged 24 ${\sim}$ 32. The health condition was judged as 'Fair' to 'Poor' conditions, according to the stream health criteria of US EPA (1993). Longitudinal variation occurred from the upstream to downstream reach; largest differences in all water quality variables occurred between Site 5 and the other sites. This was mainly attributed to the impacts of wastewater treatment plants near the locations. Also, relative proportions of tolerance and omnivore species increased in downstream reaches. The model values, however, did not match the values, based on water quality parameters. We assume that this may be associated with primarily reduced water volumn during dry season in the stream along with modified physical habitat conditions.

Effectiveness Analysis of Alternatives to Rehabilitate the Distorted hydrologic Cycle in the Anyangcheon Watershed using HSPF (HSPF 모형을 이용한 안양천 유역의 물순환 건전화 대안기술 효과분석)

  • Chung, Eun-Sung;Lee, Joon-Seok;Lee, Kil Seong;Kim, Sang-Ug;Kim, Kyung-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.973-984
    • /
    • 2007
  • This study developed and calculated alternative evaluation index (AEI) from the effectiveness analyses of alternatives for rehabilitation of distorted hydrologic cycle. The feasible alternatives for the poor-conditioned region in the Anyangcheon watershed were proposed and quantitatively analyzed using continuous water quantity/quality simulation model, Hydrological Simulation Program-Fortran (HSPF). The effectiveness analyses include 355th flow and 275th flow of flow duration curve and number of increased days to satisfy the target monthly flow for water quantity and BOD average concentration, total daily loads and number of increased days to satisfy the target concentration and total daily loads. The feasible alternatives are restoration of covered stream, prevention of streamflow loss through sewers, redevelopment of existing reservoir, reuse of treated wastewater, use of groundwater collected by subway stations and construction of small wastewater treatment plant. Therefore, alternative priority ranking was derived from AEIs. It will be effective to make an integrated watershed management for sustainable development.

A Case Study on Dry Stream Protection Design Using Causes Analysis of the Dry Stream Weakness Section (하천 건천화 취약구간 원인 분석을 통한 방지 대책: 설계사례)

  • Yoo, Chan-Ho;Park, Se-Young;Kang, Moon-Gu;Hwang, Jung-Soon;Oh, Byung-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1494-1501
    • /
    • 2008
  • Recently, the demand of water resources is constantly increasing due to the substantial increase of population, economy, and living standard. However, it is expected that the water resources should undergo serious problems of poor quality of water as well as shortage of water supply in the near future. Additionally, thoughtless groundwater development have caused to dry river and stream. In this study, the effectiveness of dry stream protection plan is evaluated by using 3-D groundwater flow modeling for the study area which is located in Namyangju of Kyoungi Province. Aquifer tests are performed to obtain the input data of the model. To analyze causes of dry stream using modeling results that water balance is analyzed for situations of before and after closing the wells.

  • PDF

Analysis for Environmental Consciousness on Conservation Planning Considering the Regional Characteristic -The Case of Daegu City- (지역특성을 고려한 환경보전계획수립을 위한 시민환경의식 분석)

  • Ryu, Ji-Won;Jung, Eung-Ho
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2071-2082
    • /
    • 2014
  • In this study, the environmental consciousness of Daegu citizen on conservation planning considering the regional characteristics was investigated. Data were collected throughout a survey and 1400 people were selected using a stratified sampling method based on populations of Daegu administration district. Results wee followings; First, the levels of environmental consciousness were different dependent on districts' characteristics. Second, poor awareness on Daegu Agenda 21 (Clear and Green Daegu 21) were shown. Daegu Agenda 21 is the action plan for the sustainable environmental conservation activities of the City of Daegu. Third, waste was the most serious environmental problems of Daegu, air quality was second worst, and third was river water quality from the survey, but differentiated awareness was shown dependent on regional spatial factors and pollution emission factors. Last, a public environmental education was the most important issue to make invigorations and progress for future environmental policy.

A Practical Approach to the Real Time Prediction of PM10 for the Management of Indoor Air Quality in Subway Stations (지하철 역사 실내 공기질 관리를 위한 실용적 PM10 실시간 예측)

  • Jeong, Karpjoo;Lee, Keun-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2075-2083
    • /
    • 2016
  • The real time IAQ (Indoor Air Quality) management is very important for large buildings and underground facilities such as subways because poor IAQ is immediately harmful to human health. Such IAQ management requires monitoring, prediction and control in an integrated and real time manner. In this paper, we present three PM10 hourly prediction models for such realtime IAQ management as both Multiple Linear Regression (MLR) and Artificial Neural Network (ANN) models. Both MLR and ANN models show good performances between 0.76 and 0.88 with respect to R (correlation coefficient) between the measured and predicted values, but the MLR models outperform the corresponding ANN models with respect to RMSE (root mean square error).

The Development of Normal Strength-High Fluidity Concrete to Improve Compaction of Concrete Wall and Flatness of Slab (충전성 및 평탄도 개선을 위한 일반강도 중유동 콘크리트 개발)

  • Kim, Yong-Ro;Park, Jong-Pil;Kim, Rae-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.55-56
    • /
    • 2022
  • Recently, water leak is increasing due to poor compaction or segregation of concrete on external wall. In addition, the flatness quality of the slab is lowered due to the deterioration of the workability of concrete. In this study, the performance of high fluidity concrete of 21MPa using a polycarboxylate-based superplasticizer was evaluated to improve the compaction and quality of the concrete wall.

  • PDF

Caking in Food Powders

  • Ruan, Roger;Choi, Young-Jin;Chung, Myong-Soo
    • Food Science and Biotechnology
    • /
    • v.16 no.3
    • /
    • pp.329-336
    • /
    • 2007
  • Caking has been a serious problem in food, feed, pharmaceutical, and related industries, where dry powdered materials are produced and/or utilized. Caking of dry food powders occurs when water is redistributed or absorbed by the powders during processing and storage. The powders become sticky when their surfaces are mobilized by water, resulting in inter-particle binding, formation of clusters, and inter-particle fusion, which lead to caking. As a result of caking, the solubility of the powdered materials may decrease, lipid oxidation and enzymatic activity may increase, and sensory qualities such as flavor and crispness may deteriorate. Caking may also lead to microbial growth. For consumers, caking of powder products is a sign of poor quality and possible food safety problems. This paper provides a review of factors affecting caking, caking mechanisms, and analysis of caking based on previous studies.

창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

An Experimental Studies on Properties of Antiwashout Admixtures (수중불분리성 혼화제의 성능평가를 위한 실험적 연구)

  • 문한영;김성수;이재준
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.51-60
    • /
    • 1999
  • When placed under water, concrete is diluted with separating cementitious material and as a result the quality of concrete becomes poor. So as to solve the problem, underwater concrete is increasingly used for the construction and repair of the concrete structure under water. In this paper, 4 kinds of antiwashout admixtures and varying sand percentages were chosen to measure the suspended solids, pH, air contents, setting time and compressive strength of underwater concrete, and they meet "Standard for antiwashout admixture used for concrete". When sand percentage is 43%, the fluidity and filling of underwater concrete are superior to the others.he others.

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.