• Title/Summary/Keyword: poor connection

검색결과 139건 처리시간 0.021초

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제10권3호
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin;Li, Rui;Jung, Heetaek;Chen, Liuyi;Oh, Kyunghwan
    • Steel and Composite Structures
    • /
    • 제15권5호
    • /
    • pp.507-518
    • /
    • 2013
  • The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

The structural detailing effect on seismic behavior of steel moment resisting connections

  • Farrokhi, Hooman;Danesh, F. Ahmadi;Eshghi, Sassan
    • Structural Engineering and Mechanics
    • /
    • 제35권5호
    • /
    • pp.617-630
    • /
    • 2010
  • Different types of moment resisting connections are commonly used to transfer the induced seismic moments between frame elements in an earthquake resisting structure. The local connection behavior may drastically affect the global seismic response of the structure. In this study, the finite element and experimental seismic investigations are implemented on two frequently used connection type to evaluate the local behavior and to reveal the failure modes. An alternative connection type is then proposed to eliminate the unfavorable brittle fracture modes resulted from probable poor welding quality. This will develop a reliable predefined ductile plastic mechanism forming away from the critical locations. Employing this technique, the structural reliability of the moment resisting connections shall be improved by achieving a controllable energy dissipation source in form of yielding of the cover plates.

전기적 신호와 열적특성 분석에 의한 접촉불량 예측 (Prediction of Poor Contact by Analysis of Electrical Signal and Thermal Characteristics)

  • 이흥수;김두현;김성철;김윤복
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.36-41
    • /
    • 2012
  • Electrical Connections often cause fires due to poor contact. Occurrence rate of these fires tends to increase annually. The reason why poor contacts occur is often because it is the low mechanical pressure at the contact points. A typical connection method using mechanical pressure is a screw terminal type. This study reviewed these poor contact cases in the screw terminals. In order to get reproduction of such cases, two types of experiments were conducted. the first one was conducted under the normal contact condition, and the other one was conducted under the poor contact condition that screw terminal of breaker was loosen and did not meet the requirements of toque value. In both types of experiments, compulsory vibration was adopted as a variable to aggravate poor contacts. Each of various current values(4.5A, 9.0A, 13.5A) is input. In these experiments, relationships of a contact, electrical signal such as current and electric pulse by ZCT and thermal characteristics according to vibration effect are analyzed. The suggested data and results in this study provide the useful resources helping to investigate fires due to poor contact, and they develop the detector for poor contact and finally reduce the electrical fire occurrence rate.

카본열선을 사용하는 전기장판의 국부가열에 의한 화재원인 분석 (Fire Cause Analysis of Local Heating on Carbon Type Hot Wire Electric Pad)

  • 송재용;김진표;남정우;사승훈
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.104-108
    • /
    • 2010
  • 본 논문은 카본열선을 사용하는 전기장판에서 발생한 전기화재에 관하여 기술하였다. 카본열선을 사용하는 전기장판은 카본 재질의 특성상 전기용접이나 납땜 등의 방법으로 접속이 불가능하며, 열선 끝단을 카본 재질의 연결부를 만들어 접속해야 한다. 이러한 과정에서 열선 사이의 불완전 접속이 발생되며, 불완전 접속부에는 접촉저항의 증가로 국부적인 발열이 발생되고, 최종적으로 화재사고로 진전된다. 본 논문에서는 카본 열선 접속부에서 불완전 접속이 형성되는 경우, 접속부에서 전기적 발열에 의해 발생되는 열선의 손상 형태를 분석하여 화재원인을 규명하였다. 이러한 분석 결과는 카본 열선을 사용하는 전기장판의 화재원인 조사의 기초 자료로 활용 가능할 것으로 기대한다.

MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구 (Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact)

  • 김동우;이기연;문현욱;김향곤;최충석
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.54-60
    • /
    • 2008
  • 본 논문에서는 MCCB 및 단자대 접속부의 접촉불량에 의한 소손특성을 분석하였으며, 발열을 감지하여 화재를 예방할 수 있는 다양한 기법들을 제시하였다. 첫째로, 열전대를 사용하는 방법과 적외선 열화상기를 사용하여 접촉불량 등의 원인에 의해서 발열을 감지하는 방법을 분석하였다. 또한, 접촉불량 발생시 변색여부로 쉽게 이상유무 판단이 가능한 서모캡의 특성을 분석하였으며, 공간 등의 제약을 덜 받으면서 접속부위에 상시 설치하고 감시할 수 있는 방식인 향 캡슐과 향 검지기를 사용하여 과열을 감지하는 시스템의 원리 및 특징을 분석하였다. 마지막으로, 가융합금의 용융특성을 응용한 접촉불량 감지나사를 제작하여 단자대에 적용 및 실험하여 성능을 검증하였다. 상기 제시된 기법들을 적절히 적용된다면 MCCB 및 단자대등의 접속부의 접촉불량에 의한 전기화재 예방에 기여할 수 있을 것으로 기대된다.

건강증진모델학교 분석: 도시 지역 대규모 초등학교를 중심으로 (Analysis of Health Promoting Schools: Focusing on Large-sized Elementary Schools in Urban Areas)

  • 김미주
    • 한국학교보건학회지
    • /
    • 제30권3호
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the operational status and operational problems of health promoting model schools, particularly of the large-sized elementary schools in urban areas. Methods: The study analyzed the data of 14 large-sized elementary schools in urban areas selected from 85 health promoting model schools, an initiative led by the Ministry of Education from 2012 to 2014. Results: The study examined the operation process of health promoting schools in five stages; system development, needs survey & current status survey, school health policy development, program development & execution, and evaluation. In addition, the study discovered three key factors in operating health promoting schools and examined the status of each factor; connection with the curriculum, connection with the community, and consensus among members. Four problems were identified as operational problems: lack of research on faculty health issues, school physical environment and community resources, inadequate presentation of performance indicators, no close coordination in core task development and lack of linkage with the curriculum. Conclusion: It turned out the concept of health promoting school suggested by WHO was relatively faithfully realized in this study. Compared to small-sized elementary schools in rural areas, health promoting schools in this study showed better aspects overall. The connection with the community was good, but the connection with the curriculum was poor.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

고학력 남자 직장인의 비만도에 따른 식생활 태도 조사 (A Study on Dietary Attitude of Male Employees of Higher Education according to Obesity)

  • 우인애
    • 한국식품영양학회지
    • /
    • 제12권5호
    • /
    • pp.462-469
    • /
    • 1999
  • The study purpose was to investigate pattern of dining-out and effects of obesity on the dietary attitude of the 213 male employees with high educational background. The results are as follows : Subjects were 20's bachelor and unmarried mostly. Mean height weight BMI and fat(%) were 172.1cm 70.5kg 23.8 and 21.3% respectively. The most frequency for dining-out was 3∼4 times/week Younger unmarried subjects had more dining-out. The most common meal for dining-out was dinner there being no connection with age, education level marrige and income. The most favorite food style among the subjects was Korean-style. Obese subjects answered that the took more consideration into nutritional balance regularity and proper amount of diet. Also they showed more food-intake especially animal protein and fats. all subjects had scores in dietary attitude there being no connection with obesity. Despite of high education they showed poor dietary attitude. Thus it is necessary to develop the nutritional education program for proper nutritional status of employees.

  • PDF

금속입자가 전도성 잉크의 전도도에 미치는 영향 (Effect of Metal Powders on the Conductivity of Conductive Inks)

  • 권두효;정태의;김남수;한국남
    • 한국공작기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.97-103
    • /
    • 2008
  • In this investigation, conductivity of conductive inks was measured. A particular attention has been given to the effect of metal powders with various conductivity on the overall conductivity of the bulk ink. The conductivity of various solutions simulating conductive inks consisting of copper and silver was measured and the results have been discussed in relation to various applications of conductive inks in practice. A conductivity model simulating systems consisting of various materials has been introduced and the results were discussed. Materials of good conductivity are adversely affected by mixing with materials of poor conductivity simply through serial connection. However, parallel connection has rather little effect on the overall conductivity. The practical implication of various mixtures of materials on conductive inks has been discussed.