• Title/Summary/Keyword: pollutant removal efficiency

Search Result 209, Processing Time 0.025 seconds

Development of the Empirical Model for Estimating the Delivered Pollutant Loads Considering Geomorphic and Hydraulic Characteristics (유역형상과 수리특성을 고려한 경험론적 유달부하식 개발)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.913-919
    • /
    • 2007
  • This study was conducted to develop a model equation to estimate the delivered point and nonpoint pollutant loads, which are critical factor to determine the water quality of watersheds. The model equation was developed by considering various factors such as biological removal and delivered distance of pollutants, basin shape and geomorphic runoff condition. The parameters for the model equation were estimated in 3 periods, which are October to March, April to June, and July to September. As a parameter, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$, a and b for $BOD_5$-delivered pollutant loads were estimated to be 0.010~0.0155, 0.051, -0.033, 0.018~0.050 and 0.93, respectively. For T-N, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$ a and b were estimated to be 0.0060~0.0140, 0.014, -0.02, 0.044~0.079 and 0.93, respectively. The same parameters for T-P were estimated to be 0.0160, 0.014, -0.0250, 0.015 and 1.21, respectively. The relationship, $E^2$ (Model efficiency), between observed and calculated delivered pollutant loads showed 0.65 for $BOD_5$, 0.81 for T-N, and 0.66 for T-P, respectively. Consequently, the model equation is effective to estimate delivered pollutant loads for TMDL.

A Study on the Factors Affecting Removal of Chromium(VI) Using $TiO_{2}$ Photocatalyst in a Circular Type Reactor (순환식 반응기에서 $TiO_{2}$ 광촉매를 이용한 Chromium(VI)의 제거에 미치는 영향인자에 대한 연구)

  • Kim, Hyun-Yong;Cho, Il-Hyoung;Lee, So-Jin;Ki, Won-Ju;Lee, Hong-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.64-69
    • /
    • 1999
  • This study was carried out the removal of Cr(VI) which was known to the toxic pollutant in industry using the process of UV and TiO$_2$ photocatalyst in a circular type reactor. In this experiment, the series of photocatalytic process for the removal of Cr(VI) has been selected as a model reaction in a circular type reactor in order to obtain the basic data on the influence of various experimental parameters such as circulation flow rate, pH of solution, initial Cr(VI) light illumination and TiO$_2$ dosage, and salicylic acid concentration. The results of this study were as follows; 1. With both UV light illumination and TiO$_2$ present, Cr(VI) was more effectively eliminated than with either UV or TiO$_2$ alone. 2. As the circulation flow rate of solution increased, the removal efficiency of Cr(VI) was increased. However, over 2.4 l/min of circulation flow rate, the efficiency wa limited. 3. A increase in the photocatalytic removal of Cr(VI) was noticed with decreasing pH. 4. An increase in the photocatalytic removal of Cr(VI) was noticed with decreasing Initial Cr(VI) concentration and first order kinetics was observed from the result at different initial concentration of Cr(VI). 5. Photocatalytic removal efficiency of Cr(VI) increased with increasing TiO$_2$ dosage. However, over 1.0 g/l of TiO$_2$ dosage, the efficiency reached a plateau. 6. As low concentration of saliculic acid were added, there was an increase in the removal efficiency of Cr(VI). However, over 300 mg/l of salicylic acid, the efficiecy was decreased. It eas found that application of photocatalysis to water treatment that contains both Cr(VI) and salicylic acid was possible.

  • PDF

A Study on the filtering bed of porous sintering-product and hydrophytes for sewage treatment (오·폐수처리를 위한 수생식물 다공성 소결체여상의 기초연구)

  • Kim, Ju-Hyung;Yun, Chan;Oh, Joon-Seong
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2001
  • The purpose of this study was to find the optimum condition of the high removal efficiency of water pollutant as sewage treatment technology using a filtering bed charged with porous sintering-pellet which was planted with hydrophytes. Experiment was carried out by changing concentration of water pollutants(COD, T-N, T-P), kind of hydrophyte, kinds of filtering material and size, and HRT. The result of removal efficiency was obtained as following: COD removal 73.8~87.1% for input concentration range of 50~450mg/L, T-N removal 61.3~77.3% for input concentration range of 7~124mg/L, T-P removal 89.5~99.1% for input concentration ranger of 3~27mg/L. In a comparative experiment of three kinds of hydrophyte(Iris pseudoacorus, Phragmites communis $T_{RIN}$., Oenanthe javanica Dc.), the best removal efficiency of COD and T-N was gained with Iris pse-udoacorus, and Phragmites communis $T_{RIN}$ showed better result than two hydrophytes for the removal efficiency of T-P. In a comparative experiment of four kinds of filtering-materials, the removal efficiencies were in the order of porous sintering-pellet, gravel, nonused-tire and nonused-concrete. It was found that for the porous sintering-pellet, the smaller its diameter, the better its result. In the filtering bed in which was charged with porous sintering-pellets of 5mm diameter and planted with Iris pseudoacorus, the removal efficiency of COD, T-N and T-P were over 80%, 70% and 90% under the concentration of COD 250mg/L, T-N 70mg/L and T-P 15mg/L for 24hrs treatment. Thus, we concluded that a filtering bed charged with porous sintering-pellet and planted with hydrophytes will be suitable for treatment of sewage water as a pro-natural treatment technology.

  • PDF

Evaluation of NOx Removal Efficiency of Photocatalytic Concrete for Road Structure (도로구조물 적용을 위한 광촉매 콘크리트의 질소산화물(NOx) 제거효율 평가)

  • Kim, Young Kyu;Hong, Seong Jae;Lee, Kyung Bae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.49-58
    • /
    • 2014
  • PURPOSES : In areas of high traffic volume, such as expressway across large cities, the amount of nitrogen oxides (NOx) emitted into the atmosphere as air pollution can be significant since NOx gases are the major cause of smog and acid rain. Recently, the importance of NOx removal has arisen in the world. Titanium dioxide ($TiO_2$), that is one of photocatalytic reaction material, is very efficient for removing NOx. The NOx removing mechanism of $TiO_2$ is the reaction of solar photocatalysis. Therefore, $TiO_2$ in road structure concrete need to be contacted with ultraviolet rays (UV) to be activated. In general, $TiO_2$ concretes are produced by replacement of $TiO_2$ as a part of concrete binder. However, considerable portion of $TiO_2$ in concrete cannot contact with the pollutant in the air and UV. Therefore, $TiO_2$ penetration method using the surface penetration agents is attempted as an alternative in order to locate $TiO_2$ to the surface of concrete structure. METHODS : This study aimed to evaluate the NOx removal efficiency of photocatalytic concrete due to various $TiO_2$ application method such as mix with $TiO_2$, surface spray($TiO_2$ penetration method) on hardened concrete and fresh concrete using surface penetration agents. The NOx removal efficiency of $TiO_2$ concrete was confirmed by NOx Analyzing System based on the specification of ISO 22197-1. RESULTS : The NOx removal efficiency of mix with $TiO_2$ increased from 11 to 25% with increasing of replacement ratio from 3 to 7%. In case of surface spray on hardened concrete, the NOx removal efficiency was about 50% due to application amount of $TiO_2$ with surface penetration agents as 300, 500 and 700g/m2. The NOx removal efficiency of surface spray on fresh concrete due to all experimental conditions, on the other hand, which was very low within 10%. CONCLUSIONS : It was known that the $TiO_2$ penetration method as surface spray on hardened concrete was a good alternative in order to remove the NOx gases for concrete road structures.

Chemical/Electro-Chemical Method for Swine Wastewater Treatment (화학적/전기화학적 방법을 이용한 돈사폐수 처리)

  • Yoon, S.J.;Jo, W.S.;Kim, C.H.;Park, J.I.;Shin, J.S.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.641-648
    • /
    • 2003
  • In a batch mode treatment process, which electrolyzes the wastewater after derivation of N-P crystal formation and recovery, the characteristics of pollutant removal induced with the changes of loading rate and hydraulic retention time were studied. $MgCl_2$ was used as Mg source for the formation of struvite and the molar ratio of $MgCl_2$ to $PO_4^{3-}$ in influent was 1.3. When analyzing the average treatment efficiencies and removal characteristics obtained from four separate operations (Run I, II, III, IV), removal efficiencies of PO43- was not function of its loading rate. Under a condition of sufficient aeration and Mg source provided, over 88% of $PO_4^{3-}$ was eliminated by the formation of MAP without any pH adjustment, in spite of loading rate variation. An optimum-loading rate of NH4-N to achieve high removal efficiency was approximately $100g/m^3/d$. Below that loading rate, the removal of NH4-N was proportional to the loading rate into the system, and hence stable and high removal efficiency, over 90%, was achieved. However, when the loading rate increased over that rate, removal efficiency began to drop and fluctuate. Removal efficiency of TOCs was dependant upon the hydraulic retention time ($r^2$=0.97), not upon the loading rate. Stable and high color removal (94%) was obtained with 2 days of HRT in electrolysis reactor.

Investigation on the Factors Affecting Urban Stormwater Management Performance of Bioretention Systems (식생체류지의 도시 강우유출수 처리효율 영향인자 조사 연구)

  • Geronimo, Franz Kevin F.;Maniquiz-Redillas, Marla C.;Hong, Jungsun;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Bioretention systems, an advance low impact development and green infrastructure approach were currently utilized in different parts of the world because it promotes biodiversity thereby mimicking and preserving the pre-developed state of an area. This study investigated and compared the capability of four bioretention systems to identify factors affecting the hydraulic capabilities and pollutant removal efficiencies of each system. The two bioretention type A referred as Type A-C and Type A-FC were planted with perennials such as Chrysanthemum and Fan columbine, respectively. On the other hand, the two type B bioretention systems referred as Type B-A and Type B-JM were planted with shrub plant species such as Azalea and Japanese Meadowsweet, respectively. Based on the results, TV, infiltration mechanism, filter media depth and plant species were identified as the factors affecting the difference in flow attenuation, retained volume and pollutant removal efficiency of Type A-C, Type A-FC, Type B-A and Type B-JM bioretention systems. The design of bioretention Type B-A and Type B-JM were advantageous considering greater volume retention, groundwater recharge, longer HRT and peak flow attenuation and greater pollutant removal efficiency. On the other hand, the design of bioretention Type A-C and Type A-FC was more appropriate for design considering reduced groundwater contamination.

Maintenance of Infiltration-type Facilities for Non-point Source Pollutant (침투형 비점오염원 처리시설의 유지관리에 관한 연구)

  • Lee, Hosik;Lee, Sanghwan
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.145-152
    • /
    • 2013
  • This study was conducted to improve the Nonpoint-source pollutant treatment plant efficiency and maintenance. Field and laboratory permeability test were conducted three times each before and after displacement. The removal efficiency such as TSS, BOD, CODmn, T-N, and T-P were investigated from the year of 2006 to 2011. The coefficient of permeability right after displacement was calculated to be $1.07{\times}10^{-3}(cm/s)$, coefficient of permeability after a year was calculated to be $0.88{\times}10^{-3}(cm/s)$, and after five years, it was calculated to be $0.3{\times}10^{-3}(cm/s)$ and accordingly, the amount of infiltration decreased. In case of the removal efficiency, it generally tended to decrease, but it showed the higher rates than the expected rates BOD 40%, SS 76%, T-N 39% and T-P 53%. It is concluded that displacement cycle should be at least five years and that dredging cycle should be at least three months and at most one year.

Drainage and Treatment Characteristics of Runoff by Media (여재에 따른 도로면 유출수의 배수 및 처리특성)

  • Kim, Seog-gu;Yun, Sang-Ieen;Kim, Young-im;Lee, Yong-jae;Kim, Ree-ho;Kim, Jong-oh
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.500-505
    • /
    • 2004
  • While more attention has been paid in recent years to urban point source pollution control, no considerable measures have been taken to control urban non-point source pollution. Contaminants from non-point sources deposited on urban impermeable surfaces such as road and highway are easily released to the public waters by rainfall, leading to the deterioration in water quality in urban area. The present study investigated a system using filter media to reduce the level of contamination in urban road runoff. Three different media, designated as J-P (polypropylene, blowing type), B-P (polypropylene, fiber type), and P-F (Polyvinyl alcohol, cube and sheet type) were evaluated on the basis of pollutant removal efficiency as well as hydraulic property. Experiments were peformed using a 1/4-scale treatment unit at various pollutant roading and rainfall intensity with real rainwater runoff collected from road surfaces. The results at different rainfall intensities shows that the medium J-P is superior to the other media for water permeability. J-P was not blocked at 10 mm/hr rainfall and its permeability was stable. On the other hand, B-P and P-F resulted in substantial overflow ratio even at I mm/hr rainfall intensity. Comparing treatment efficiencies for suspended solids, all media showed similar removal ranged from 91 % to 95%. However, J-P seems to be better than the other media considering its higher water permeability. J-P and P-F, both hydrophobic, yielded over 76% of heavy metal removal. But, the hydrophilic media B-P showed much smaller removal ranging from 26% to 47%. This indicates that J-P and P-F are beneficial to remove heavy metal due to their hydrophobic property. The treatment efficiencies over PAHs (poly aromatic hydrocarbons) showed the similar removal efficiency ranging from 66% to 97% for all three media.

A Study on the removal of B.T.X by UV Photooxidation-Activated Carbon (광산화-활성탄 복합공정에 의한 B.T.X. 분해에 관한 연구)

  • Jeong, Chang Hun;Bae, Hae Ryong
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In this study, The decomposition of gas-phase Benzene and Toluene, Xylene in air streams by direct UV Photolysis, UV/TiO$_2$ and UV/TiO$_2$/A.C process was studied. The experiments were carried out under various UV light intensities and initial concentrations of B.T.X to investigate and compare the removal efficiency of the pollutant. B.T.X was determined by GC-FID of gas samples taken from the a glass sampling bulb which was located at reactor inlet and outlet by gas-tight syringe. From this study, the results indicate that UV/TiO$_2$/A.C system (photooxidation-photocatalytic oxidation-adsorption process) is ideal for treatment of B.T.X from the small workplace. Although the results needs more verifications, the methodology seems to be reasonable and can be applied for various workplace (laundry, gas station et al.).

Effect of Removal Efficiency of Formaldehyde by Input Coating Concentration of Photocatalyst - with Study of Standardization of Coating Thickness - (광촉매 코팅농도가 포름알데히드 제거능에 미치는 효과 - 코팅 두께 표준화 연구를 중심으로 -)

  • Park Young G.;Han Man-So
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.51-58
    • /
    • 2005
  • Photocatalytic degradation using $TiO_2$ Particles suspended in a reactor was experimentally performed to degrade the formaldehyde of indoor pollutants. Exponential increase of degradation appears to prove light availability due to the scattering of W light by particles themselves. Comparative removal studies of formaldehyde were done in both cases of dipping and spraying immobilized techniques of $TiO_2$ Particles suspended in solution. Experiments were performed under several different experimental conditions such as initial concentration of formaldehyde, UV intensity and concentration of photocatalysts. Optimal conditions to degrade formaldehyde were obtained under the conditions of $30\;mg/cm^2$ concentration of catalyst and UV intensity of 30 Watt at the distance of 30 cm using immobilized technique by dipping coating.