• 제목/요약/키워드: polar low

검색결과 526건 처리시간 0.021초

Diel Cycles of Nitrogen Uptake by Marine Phytoplankton in NO$_3^-$-high and -low Environments

  • Park, Myung-Gil;Shim, Jae-Hyung;Yang, Sung-Ryull;Lee, Sang-Hoon;Cho, Byung-Cheol
    • Journal of the korean society of oceanography
    • /
    • 제32권4호
    • /
    • pp.191-201
    • /
    • 1997
  • To test the roles of NO$_3^-$ concentration and light as controlling factors of NO$_3^-$ uptake in the NO$_3^-$-low and -high environments and to assess the significance of night-time nitrogen (N) uptake in estimating the daily N uptake rate, 2 diel studies of N uptake were conducted in NO$_3^-$-low (the eastern part of the Yellow Sea) and NO$_3^-$-high (the marginal ice zone of the northwestern Weddell Sea) environments on June 14 to 15, 1996 and January 15 to 16, 1995, respectively. Ourobservations confirmed that NO$_3\;^-$ uptake by phytoplankton is mainly determined by ambient NO$_3^-$ concentration in NO$_3^-$-low environment and by light in NO$_3^-$-high environment, respectively, Our results suggest the need for diel studies to accurately estimate the daily N uptake rates and thus new and regenerated production because the daily rates calculated without considering the night-time N uptake would be significantly underestimated (up to 41%), particularly in the NO$_3^-$-low environment.

  • PDF

디젤유/바이오디젤유-열분해유-부탄올 혼합유의 디젤 엔진 적용 가능성에 관한 연구 (A Feasibility Study of Using Diesel/Biodiesel-Pyrolysis Oil-Butanol Blends in a Diesel Engine)

  • 김호승;장영운;이석환;김태영;강건용;윤준규
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.116-125
    • /
    • 2014
  • Pyrolysis oil (PO), derived from biomass through fast pyrolysis process have the potential to displace significant amounts of petroleum fuels. The PO derived from wood has been regarded as an alternative fuel to be used in diesel engines. However, the use of PO in a diesel engine is very limited due to its poor properties like low energy density, low cetane number, high acidity and high viscosity of PO. Therefore, one of the easiest way to adopt PO to diesel engine without modifications is blended with other fuels that have high centane number. However, PO that has high amount of polar chemicals is immiscible with non polar hydrocarbons of diesel or biodiesel. Thus, to stabilize a homogeneous phase of diesel/biodiesel-PO blends, a proper surfactant should be used. Nevertheless, PO which was produced from different biomass type have varied characteristics and this complicates the selection of a suitable additive for a specific PO-diesel emulsion. In this regard, a more simple approach such as the use of a co-solvent like ethanol or butanol to induce a more stable phase of the PO-diesel mixture could be a promising alternative. In this study, a diesel engine operated with diesel/biodiesel-PO-butanol blends was experimentally investigated. Performance and gaseous & particle emission characteristics of a diesel engine were examined under the engine loads of IMEP 0.2 ~ 0.8MPa.

자외선 열화 전후 건조 옻의 용매별 용출 특성 (Extraction Characteristics of Dried Asian Lacquer by Solvents Before and After UV Degradation)

  • 박종서
    • 보존과학회지
    • /
    • 제36권2호
    • /
    • pp.103-111
    • /
    • 2020
  • 건조칠기 유물 세척 시 사용되는 다양한 용매을 대상으로 클리닝 효과를 비교하기 위해 실험을 진행하였다. 건조칠과 자외선에 24일 노출시킨 건조칠에 물, 에탄올, 아세톤, 헥산을 가하여 녹아 나오는 물질을 열분해/GC/MS로 검출하였다. 용출되는 양은 아세톤과 에탄올에서 많았으며, 극성이 높은 용매인 물은 저분자량 용출에 비교적 효율이 좋았다. 비극성 용매인 헥산은 용출량이 매우 낮았다. UV에 24일 노출되어 열화가 많이 진행된 건조칠은 노출되기 전 건조칠에 비해 용출되는 물질이 크게 증가하였다. 열화가 되면서 고분자 형태의 우루시올 사슬이 절단되고 산화되는 과정을 거쳐 dicarboxylic acid를 포함한 저분자량의 극성 물질을 생성하기 때문인 것으로 보인다. 이와 같은 용출특성은 칠기유물을 클리닝하는 용매를 선택할 때 유물의 열화 상태와 더불어 중요한 참고자료가 될 것이다.

Effect of a Compatibilizer on the Microstructure and Properties of Partially Biodegradable LDPE/Aliphatic Polyester/Organoclay Nanocomposites

  • Hwang Kun-Jun;Park Jin-Woo;Kim Il;Ha Chang-Sik;Kim Gue-Hyun
    • Macromolecular Research
    • /
    • 제14권2호
    • /
    • pp.179-186
    • /
    • 2006
  • In the present work, low density polyethylene (LDPE)/aliphatic polyester (APES)/organoclay ternary nanocomposites were prepared. In particular, the effect of a compatibilizer, polyethylene-graft-maleic anhydride (PE-g-MAH), on the morphology and properties of the ternary nanocomposites was investigated. LDPE/APES/organoclay nanocomposites were prepared through melt intercalation method using two different kinds of organoclay. The dispersibility of silicate clays in the nanocomposites was investigated by X-ray diffraction and atomic force microscopy. The ternary nanocomposites showed higher tensile properties than the LDPE/APES blend did. The dispersibility and properties of nanocomposites containing Cloisite 30B were better than those of the nanocomposites containing Cloisite 20A. Unlike Cloisite 20A, hydroxyl groups in the intercalants in Cloisite 30B interlayer underwent a certain polar interaction with the carboxyl group of APES, favoring the intercalation of APES chains and the formation of LDPE/APES/Closite 30B nanocomposites. However, the introduction of the polar hydroxyl groups also enhanced the interaction with the silicate surface at the same time, thereby rendering somewhat difficult the replacement of the surface contacts by LDPE chains, and impeding the extensive intercalation and further exfoliation of Cloisite 30B in the LDPE/APES matrix. The compatibilizer enhanced the intercalation of the polymer chain inside the clay gallery and thus improved the mechanical properties of the ternary nanocomposites. Rheological measurements of the nanocomposites via frequency sweep experiment indicated a certain interaction between the clay platelet and the polymer molecules in the melted state.

동해중층수의 일반적인 분포 특성 (General Characteristics of the East Sea Intermediate Water)

  • 신창웅;변상경;김철수;이재학;김봉채;황상철;승영호;신홍렬
    • Ocean and Polar Research
    • /
    • 제29권1호
    • /
    • pp.33-42
    • /
    • 2007
  • To obtain the overall distribution patterns and characteristics of the East Sea Intermediate Water (ESIW), the historical data obtained by the Japan Maizuru Marine Observatory (MMO) and the Korea Ocean Research and Development Institute (KORDI) were analyzed. To obtain water characteristics of the ESIW on isopycnal surfaces, temperature, salinity and dissolved oxygen were interpolated at every 0.01 interval of potential density. And then the interpolated values were averaged at the same potential density. This potential density average method preserved the salinity minimum layer more clearly compared to the depth average method. The potential density(${\sigma}_{\theta}$) range of the ESIW was $26.9{\sim}27.3$. The representative potential density of the ESIW was found to be 27.2, because the characteristics of the ESIW was clear at this density. From the horizontal distributions of physical properties on the isopycnal surface of $27.2{\sigma}_{\theta}$ it is suggested that the low salinity ESIW circulates anticlockwise over the whole basin with the high salinity intermediate water. The low salinity intermediate water extended from the northwestern part to the east along the sub-polar front and to the Ulleung Basin along the east coast of Korea.

GPS TEC Fluctuations in the Low and High Latitudes During the 2015 St. Patrick's Day Storm

  • Chung, Jong-Kyun;Hong, Junseok;Yoo, Sung-Moon;Kim, Jeong-Han;Jee, Geonhwa;Hegai, Valery V.
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권4호
    • /
    • pp.245-250
    • /
    • 2017
  • As a part of collaborative efforts to understand ionospheric irregularities, the Korea ionospheric scintillation sites (KISS) network has been built based on global positioning system (GPS) receivers with sampling rates higher than 1 Hz. We produce the rate of TEC index (ROTI) to represent GPS TEC fluctuations related to ionospheric irregularities. In the KISS network, two ground-based GPS sites at Kiruna (marker: KIRN; geographic: $67.9^{\circ}$ N, $21.4^{\circ}$ E; geomagnetic: $65.2^{\circ}$ N) and Chuuk (marker: CHUK; geographic: $7.5^{\circ}$ N, $151.9^{\circ}$ E; geomagnetic: $0.4^{\circ}$ N) were selected to evaluate the ROTI value for ionospheric irregularities during the occurrence of the 2015 St. Patrick's Day storm. The KIRN ROTI values in the aurora region appear to be generally much higher than the CHUK ROTI values in the EIA region. The CHUK ROTI values increased to ~0.5 TECU/min around UT=13:00 (LT=23:00) on March 16 in the quiet geomagnetic condition. On March 17, 2015, CHUK ROTI values more than 1.0 TECU/min were measured between UT=9:00 and 12:00 (LT=19:00 and 22:00) during the first main phase of the St. Patrick's Day storm. This may be due to ionospheric irregularities by increased pre-reversal enhancement (PRE) after sunset during the geomagnetic storm. Post-midnight, the CHUK ROTI showed two peaks of ~0.5 TECU/min and ~0.3 TECU/min near UT=15:00 (LT=01:00) and UT=18:00 (LT=04:00) at the second main phase. The KIRN site showed significant peaks of ROTI around geomagnetic latitude=$63.3^{\circ}$ N and MLT=15:40 on the same day. These can be explained by enhanced ionospheric irregularities in the auroral oval at the maximum of AE index

극 좌표를 이용한 클러스터 기반 센서 네트워크의 키 관리 기법 (A key management scheme for the cluster-based sensor network using polar coordinated)

  • 홍성식;유황빈
    • 한국정보통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.870-878
    • /
    • 2008
  • 센서 네트워크를 구성하는 센서 노드는 대부분 보안성이 낮으며, 낮은 연산 능력과 적은 저장 용량으로 효율적인 보안 알고리즘을 적용할 수 없다. 따라서 불법적인 노드의 침입을 억 제할 수 없으며, 센서 노드의 전송 알고리즘만 알게되면 전송되는 정보를 쉽게 도청 할 수 있는 문제점을 갖게 된다. 본 논문에서는 센서 네트워크를 클러 터로 구분하고, 클러스터 내에서 센서 노드가 안전하게 정보를 전송할 수 있으며 불법적인 센서 노드의 침입을 억제할 수 있는 극좌표를 이용한 클러스터 기반의 센서 네트워크의 키 관리기법을 제안한다. 제안된 기법에서는 클러스터 내에서 모든 센서 노드는 CH(Cluster Header)가 제공하는 피벗값을 기반으로 인증키를 설정하도록 하고있다. 시뮬레이션 결과 기존의 페어 와이즈(pair-wise) 기법에 비하여 키 관리측면에서 안전한 키 관리와 불법적인 노드의 침입을 억 제할 수 있는 우수함을 증명하였다.

도전성 고무 매트를 이용한 수소 기반 시설에서 제전 신뢰성 향상 (Conductive Rubber for Enhanced Safety in Hydrogen-based Facilities from Electrostatic Discharge)

  • 이수운;고재환;송지원;김찬우;김충일;김해술;허만억;정재형;송형준
    • 한국안전학회지
    • /
    • 제39권1호
    • /
    • pp.9-15
    • /
    • 2024
  • Hydrogen-based electricity and transportation systems are widely recognized as sustainable power sources. However, the low ignition energy of hydrogen, only 1/10th that of conventional fossil fuels, poses a safety concern involving the risk of ignition due to electrostatic discharge from facility workers. Therefore, anti-static systems are imperative for hydrogen-based electricity facilities. To address this, we propose a reliable conductive rubber mat (CRM) to ensure the safety of these facilities. Unlike conventional anti-static floors that utilize conductive paint (CP), the CRM features a uniform distribution of conductive components in chemically and mechanically stable rubber. As a result, the CRM is unyielding to polar solvents (such as ethanol and hydrosulfuric acid) and non-polar solvents (like mineral oil) without increasing its resistance. Moreover, the CRM can withstand mechanical stress. Consequently, the human-body voltage of workers on the CRM would be sufficiently low enough to protect them from hydrogen explosions, thereby enhancing overall safety.

확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향 (Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors)

  • 한진구;노영만;김현욱
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF

SONDRESTROM 비간섭 산란 레이더 자료를 이용한 극지방 전리층의 기후학적 특성 연구 (CLIMATOLOGICAL CHARACTERISTICS OF THE POLAR IONOSPHERE BASED ON THE SONDRESTROM INCOHERENT SCATTER RADAR MEASUREMENTS)

  • 곽영실;안병호
    • Journal of Astronomy and Space Sciences
    • /
    • 제19권1호
    • /
    • pp.75-88
    • /
    • 2002
  • 전리층의 전기 전도도와 전기장을 구함으로써 극지방 전리층의 기후학적 특성을 살펴보았다 이를 위해, 총 109일간의 Sondrestrom 비간섭 산란 레이더 자료를 이용하였다. 전기 전도도와 전기장을 이용하여 전리층 전류 분포를 추정하였고, 구해진 전리층 전류 밀도와 그로 인해 유발되는 지상 지자기 변화를 비교하였다. 또한 지상 지자기 변화(특히, D 성분)에 대한 연자기력선 전류의 효과도 검토되었다. Sondrestrom 상공 전리층에 대한 몇 가지 흥미로운 기후학적 특성을 본 연구로부터 알 수 있었다: (1) 주간의 전기 전도도 분포는 주로 태양 EUV복사에 의한 것이며, 야간에는 미약하다. (2) 극관 영역 전리층의 전기 전도도 분포는, 주간에는 태양 EUV복사에 의한 분포를 보이는 반면, 야간에는 Hall 및 Pedersen 전기 전도도의 시간 평균이 각각 1.6 및 1.2 siemen으로 아주 낮다. (3) 남북 성분 전기장의 최대치가 낮 영역에 나타나는 경향이 있다. 동서 성분 전기장은 Chatanika에 비해 강하다 (4) 동서 성분 전류는 낮 영역에서 강하게 흐른다. 정오 바로 전에 강한 남향 전류가 흐른다. (5) 오로라제트전류와 동시에 관측된 지상 지자기 변화 $({{\Delta}}H)$ 사이에 높은 상관관계를 나타낸다. 하지만 무한판상을 가정한 전류가 크게 과소평가 된다. 또한 ${{\Delta}}H$의 관계보다 더 높게 나타나며, 이것은 연자기력선 전류가 ${\Delta}7$에 영향을 미친다는 것을 의미한다.