• Title/Summary/Keyword: point-contact

Search Result 1,216, Processing Time 0.032 seconds

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle (II) - Reliability and Reproducibility of the New Automatic Measuring System for Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제2보) -자동 접촉각 측정 시스템의 신뢰성 및 재현성 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.53-58
    • /
    • 2003
  • The newly developed system for measuring a contact angle on a sheet was examined to investigate reliability and reproducibility of the measured results. It was clearly confirmed that the automatic contact angle measuring system was much faster and more reliable way to determine the water resistance of a sheet, comparing with Cobb and Stockigt sizing tests. Cobb test showed less significant results with stringently sized sheets, and Stockigt test exhibited the big deviations by discrepancy of the recognition point of coloring according to different testers in spite of explicit test results. On the other hand, the contact angles measured by the automatic system were reproduced with less deviations, irrespectively of different testers. It was interesting to note that the contact angle might be able to used to predict Cobb and Stockigt sizing degree, based upon the high correlation coefficients of 0.95 and 0.97. Hereafter the automatic system will be upgraded to predict Cobb and stockigt sizing degree through the measurement of contact angle.

A STUDY ON THE DEGREE OF OCCLUSAL CONTACT UNDER THE FIXEDIMPLANT PROSTHESIS OF PARTIALLY DENTULOUS PATIENTS (부분 무치악 고정성 임플랜트 보철하에서 교합접촉정도에 관한 연구)

  • Song, Keum-Young;Kay, Kee-Sung;Cjung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.281-299
    • /
    • 1995
  • The purpose of this study was to evaluate the degree of occlusal contact under the fixed implant prosthesis of partially edentulous patients which was hased on occlusal concept of implant prosthesis. From the patients who have free-standing implant supported prosthesis of unilateral partially edentulous area, occlusal and occlusal contact point of th enatural tooth side and implant side of light closure and heavy closure were analyzed by T-scan system throuht pre-and post-adjustment and the degree of occlusal contact was estimated by Shimstock. The following results were obtained : 1. The occlusal force of natural tooth side(NF) from mid-sagittal axis was relatively constant at light and heavy closure through pre-and post-adjustment, but the occlusal force of implant side(IF) was decreased significantly at light closure(P<0.01) and heavy closure(P<0.05) of post-adjustment. 2. Natural tooth side-implant side moment(MIMoment) fo occlusal force from mid-sagittal axis was significant(p<0.05) through pre-and post-adjustment and the deviation from mid-sagittal axis was increased at light closure of post-adjustment, but was decreased at heavy closure of post-adjustment. 3. Comparing the NF and IF, IF was greater at heavy closure of pre-adjustment, and NF was greater at light closure of post-adjustment, and the NF and IF was relatively equally distributed at light closure of pre-adjustment and at heavy closure of post-adjustment. 4. The number of occlusal contact point of natural tooth side(NC) was relatively constant through pre-and post-adjustment, but the number of occlusal contact point of implant side(IC) was significantly decreased(P<0.05) at light closure of post-adjustment, and was not significant but was lesser at heavy closure of post-adjustment. 5. Difference of the NC and IC was greater at light closure of post-adjustment, but it was less at heavy closure of post-adjustment, and therefore occlusal contact point of natural tooth side and implant side was relatively equally distributed at heavy closure of postadjustment. 6. When bilaterally distribution of occlusal force and occlusal contact point was established, degree of occlusal contact of implant suporoted prosthesis with opoosing teeth at light clousre was $34.13{\pm}21.69{\mu}m$.

  • PDF

Dynamic Wheel/Rail Contact Force due to Rail Irregularities (레일의 상하방향 불규칙성에 의한 차륜과 레일의 동 접촉력)

  • 이현엽
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.616-622
    • /
    • 1998
  • An analytical method has been developed to estimate the dynamic contact force between wheel and rail when trains are running on rail with vertical irregularities. In this method, the effect of Hertzian deformation at the contact point is considered as a linearized spring and the wheel is considered as an sprung mass. The rail is modelled as a discretely-supported Timoshenko beam, and the periodic structure theory was adopted to obtain the driving-point receptance. As an example, the dynamic contact force for a typical wheel/rail system was analysed by the method developed in this research and the dynamic characteristics of the system was also discussed. It is revealed that discretely-supported Timoshenko beam model should be used instead of the previously used continuously-supported model or discretelysupported Euler beam model, for the frequency range above several hundred hertz.

  • PDF

Development of On-machine Measurement System utilizing a Capacitive-type Sensor (정전용량형 센서를 이용한 기상계측시스템의 개발)

  • 김건희;박순섭;박원규;원종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF

Relationship between Interdental Papilla Existence & Distance from Interdental Alveolar Crest to Contact Point in the Posterior Dentition of Korean adults (한국인 구치열에서 치간유두 존재와 치아접촉점과 치간골 거리와의 관계)

  • Kim, Hyun-Chul;Jeon, Yong-Seon;Chang, Moon-Taek;Kim, Hyung-Seop;Park, Jung-Mi
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.625-631
    • /
    • 2001
  • The anatomic structure around interproximal area plays an important role not only in the natural teeth, but also in the implant. The loss of papilla can lead to cosmetic deformity, phonetic problem, food impaction on the anterior dentition, and masticatory problem, food impaction and proximal caries on the posterior dentition. The purpose of this study was to evaluate the relationship between interdental papilla existence and distance from contact point to alveolar crest in Korean posteior dentition. 45 Korean adult patients(31males, 14 females) participated in this study. Measurements were carreid out total 126 interproximal areas, 18 first premolar, 31 second premolar, 40 first molar, and 37 second molar areas. Papilla index was recorded as suggested by Jemt. Distance between contact point and alveolar crest measrued by Florida $probe^{R}$, after flap elevation. Each distance was measured 10 times by every 0.1mm unit. The results showed that the mean Papilla index 1.37 and mean distance between contact point and alveolar crest was 7.44mm. The correlation between the Papilla index and distance was high negative correlation(Pearson correlation=-0.47), and it was statistically significant(P=0.000) When the distance between contact point and alveolar crest was 5mm, the loss of papilla was appeared almost in half cases. When the distance was 6mm, the papilla loss was present 95%, when 7mm, the papilla loss was 100%.

  • PDF

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

ROLL CENTER ANALYSIS OF A HALF-CAR MODEL USING POLE FOR SMALL DISPLACEMENT

  • Lee, J.K.;Shim, J.K.
    • International Journal of Automotive Technology
    • /
    • v.7 no.7
    • /
    • pp.833-839
    • /
    • 2006
  • In this paper, roll behavior of three planar half car models are compared. The first model is a simple model whose contact point between a wheel and the ground is assumed to be fixed with a revolute joint. The second model is a modified model of the fIrst model, whose wheel tread width can vary. In this model, the instant center of a wheel with respect to the ground, which is crucial to find the roll center, is assumed to be at the contact point of a wheel and the ground. The last model uses the pole of a wheel with respect to the ground for small displacement as the instant center of a wheel with respect to the ground. Loci of the center of gravity point, the fixed and the moving centrodes which are traces of roll center position in the ground and the body frame respectively, wheel contact points, and instant centers of a wheel with respect to the ground are calculated.

Thermal Analysis for High Efficiency of Point Contact Solar Cell (후면전극형 태양전지의 열해석에 관한 연구)

  • Nam, Tae-Jin;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.351-354
    • /
    • 2011
  • This paper was carried about thermal analysis for high efficiency point contact solar cell. Therefore, we carried about 2-D device and process simulator according to design and process parameters. As a result of simulations, power transfer efficiency have decreased more increasing temperature. Especially, power transfer efficiency of room temperature have been showed 25%. The other hand, power transfer efficiency of 350 K kalvin temperature have been showed 20%. Therefore, we will considered design with thermal dissipation of device.

Development of Contact Point Estimation Algorithm of Dry type Clutch with Considering the friction pad wear (마찰패드의 마모를 고려한 건식 클러치의 접촉점 추종 알고리즘 개발)

  • Kim, Sung-Mo;Kim, Mo-Seong;Shin, Chang-Woo;Lim, Won-Sik;Cha, Suk-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.692-696
    • /
    • 2011
  • A clutch is a very important component when engine starts and gear shifting is needed. The clutch the most commonly used is the dry clutch. This type of clutch has pads, and they are worn after disengagement of clutch little by little. The characteristics of the clutch changes as these pads wear, so wear needs to be measured, and the clutch should be controlled for proper operation. In this study, the clutch contact point estimation algorithm has been developed. From this algorithm, clutch force map changes depending on wear, and the clutch operates properly. We also see the shifting transient of a vehicle for drivability with throttle valve position control and synchronizer movement.

Measurement of Film Thickness by Fringe Intensity Analysis in Point Contact Elastohydrodynamic Lubrication (점접촉 탄성 유체 윤활에서의 띠 무의 강도에 의한 유막 두께 측정)

  • 장시열;최언진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.103-113
    • /
    • 1999
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by the image processing method for the monochromatic incident light. Interference between the reflected lights both on Cr coating of glass disk and on super finished ball makes circular fringes, which are regarded as film thickness together with numbering of fringe order. In this study, we developed technology to measure the film thickness by analyzing dark and bright intensity waves which results from monochrome green light. Two typical fringe patterns only with intensity values 3re examined for the measurement of point contact EHL film thickness. We expect that this technology will give valuable clue to improve color image processing analysis for high resolution of EHL film thickness with white incident light.

  • PDF