• Title/Summary/Keyword: point to point (P2P)

Search Result 3,517, Processing Time 0.046 seconds

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

The Formative Characteristics of Seogo-jeongsa & Sameun-jeong Byeolseo Gardens in Toerori Miryang (밀양(密陽) 퇴노리(退老里) 서고정사(西皐精舍)와 삼은정(三隱亭) 별서(別墅)의 조영(造營) 특성(特性))

  • Lee, Hyun-Woo;Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.4
    • /
    • pp.70-83
    • /
    • 2013
  • To widen prospect of villa as Korea traditional garden, the result of the research about constructional characteristics of Seogo-jeongsa and Sameun-jeong of Yeoju Lee family at Toero-ri, Miryang-si, Gyeongsangnam-do, Korea, is abstracted as below. Seogo-jeongsa(西皐精舍) and Sameun-jeong(三隱亭) was intended to practise retirement with sense of unity with the head residence, since Seogo-jeongsa was 340m far and sameun-jeong was 630m far away from head residence, which set within 1km. Although Seogo-jeongsa's basic prop, Sameun-jeong's timber, which are both from designer's pen name and head residence name, "Hangjae(恒齋)" and "Yongjae(庸齋)," and Hanseoam have each different exposure, it is homogeneous as space configurational side in order to optimize the gaze leading effect and appreciated domestic trees from the pond, which is center of the garden and the significant facility. Method of direction of Seogo-jeongsa's Hwalsudang(活水塘) and Sameunjeong's pond of Sameun-ji(三隱 池) gets attention by distinction. Especially, directing of 3 step water flow from behind to front and traditional pond method, called Bangji-Bangdo(方池方島), were very unique that any other place can be found. Also, the middle islet on the pond at both villa, which isn't more supper, but more for the symbolic molding that seek a stone pagoda(石假山), is more interesting directing method as considering the relationship of the 3 stone pagoda imageries on the surface of Ghwayukchon(果肉泉) At the same time, Seogo-jeongsa and Sameun-jeong shows very different characteristics from traditional villa that adopted both domestic trees and foreign trees. Particularly, it is extremely exceptional case to plant vigorous needleleaf tree, such as Chamaecyparis pisifera, C. obtusa, Pinus bungeana, P. palustris, Sciadopitys verticillata, Metasequoia glyptostroboides and Cedrus deodara, on Sameun-jeong. Moreover, adopting foreign wild needleleaf trees for landscaping trees, such as a Torreya nucifera, Taxus cuspidata, P. parviflora, and foreign landsacping trees, such as P. bungeana, Cryptomeria japonica and C. obtusa tells planting trend of the late Joseon dysnasty era. Also, as we can know from 2 Jipgyeong(集景), which is 'Seogo-jabyoung 17 young(西皐雜詠十七詠)', and 'Sameun-jeong 12 Gyoung(三隱亭十二景)' which are set on both villa, the intend to expand the garden area is strongly shown by the natural forest directing. As a result, Seogo-jeongsa and Sameun-jeong, located at Toero-li Miryang, are sharing the traditional Joseon dynasty era's custom, such as space and visual composition; however, it is different and attractive garden remains as a point of view of water directing, stone pagodas, and adopting foreign landscaping trees.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

A Study on the Model Development and Empirical Application for Predicting the Efficiency and Optimum Size of Investment in Domestic Seaports (국내항만투자의 효율성 및 적정 투자규모 예측을 위한 모형개발 및 실증적 적용에 관한 연구)

  • Park, Ro-Kyung
    • Journal of Korea Port Economic Association
    • /
    • v.26 no.3
    • /
    • pp.18-41
    • /
    • 2010
  • The purpose of this paper is to show the empirical measurement way for predicting the seaport efficiency by using Super SBM(Slack-based Measure) with Wilcoxson signed-rank test under CRS(constant returns to scale) condition for 20 Korean ports during 11 years(1997-2007) for 3 inputs(port investment amount, birthing capacity, and cargo handling capacity) and 5 outputs(Export and Import Quantity, Number of Ship Calls, Port Revenue, Customer Satisfaction Point for Port Service and Container Cargo Throughput). The main empirical results of this paper are as follows. First, Super SBM model has well reflected the real data according to the Wilcoxon signed rank test, because p values have exceeded the significance level. Second,Super-SBM has shown about 87% of predicting ratio for the ports efficiency and the optimal size of investment in domestic seaport. The policy implication to the Korean seaports and planner is that Korean seaports should introduce the new methods like Super-SBM method with Wilcoxon signed rank test for predicting the efficiency of port performance and the optimal size of investment as indicated by Panayides et al.(2009, pp.203-204).

Assessment of buccal bone thickness of aesthetic maxillary region: a cone-beam computed tomography study

  • Fuentes, Ramon;Flores, Tania;Navarro, Pablo;Salamanca, Carlos;Beltran, Victor;Borie, Eduardo
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • Purpose: The aim of this study was to analyze the anatomical dimensions of the buccal bone walls of the aesthetic maxillary region for immediate implant placement, based upon cone-beam computed tomography (CBCT) scans in a sample of adult patients. Methods: Two calibrated examiners analyzed a sample of 50 CBCT scans, performing morphometric analyses of both incisors and canines on the left and right sides. Subsequently, in the sagittal view, a line was traced through the major axis of the selected tooth. Then, a second line (E) was traced from the buccal to the palatal wall at the level of the observed bone ridges. The heights of the buccal and palatal bone ridges were determined at the major axis of the tooth. The buccal bone thickness was measured across five lines. The first was at the level of line E. The second was at the most apical point of the tooth, and the other three lines were equidistant between the apical and the cervical lines, and parallel to them. Statistical analysis was performed with a significance level of $P{\leq}0.05$ for the bone thickness means and standard deviations per tooth and patient for the five lines at varying depths. Results: The means of the buccal wall thicknesses in the central incisors, lateral incisors and canines were $1.14{\pm}0.65mm$, $0.95{\pm}0.67mm$ and $1.15{\pm}0.68mm$, respectively. Additionally, only on the left side were significant differences in some measurements of buccal bone thickness observed according to age and gender. However, age and gender did not show significant differences in heights between the palatal and buccal plates. In a few cases, the buccal wall had a greater height than the palatal wall. Conclusions: Less than 10% of sites showed more than a 2-mm thickness of the buccal bone wall, with the exception of the central incisor region, wherein 14.4% of cases were ${\geq}2mm$.

A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD (정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구)

  • Shin, Dong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

한국산의 죽류에 관한 연구(제육보) 산죽류의 번식에 관하여

  • 정현배
    • Journal of Plant Biology
    • /
    • v.7 no.2
    • /
    • pp.9-13
    • /
    • 1964
  • As to the up-lnd bamboos, I have reported, in my previous works, that Korea has two species in the genus of Pseudosasa, four in Pleioblastus, and other four in Sasa. In the present work, I dealt with Sasamorpha Purpurascens Nakai var. Borealis Nakai which proved the strongest vitality of all up-land bamboo yet found in various up-lands of Korea, and which might be most important from the utility view-point. This report is chiefly on its procreation. Sasamorpha Purpurascens Nakai var. Borealis Nakai can be found almost everywhere throughout the country, and its leaves and stems are much used in farms in various forms of manufacture. It is also welcomed as the feed for livestocks and as cover plants for aforestation, especially as the excellent means of errosion control on devastated hill sides. It is also widely accepted that it will provide, in the immediate future, abundant sources for the up-land bamboo pulp. As the first phase of my research plan on the subject, I undertook to determine the possible best way of its procreation, for which were included the experiments of inducing the growth of subterranean stems, the entire stand cutting, transplanting, reclaimed planting after burning etc. in order to observe the plant elongation, growing conditon, climatical effect etc. What has been fuond out so far given here as follows: 1) Of the various sections of the country, Mt. Odae area gives out the most excellent Sasamorpha Purpurascens Nakai var. Borealis Nakai(the leaf weight of which is 450 gr.) and Taekwanryong area comes the next class. This species can be transplanted anywhere in the South Korea. 2) The elongation of S.P. Nakai var. Borelais begins at around the middle of May and almost completely stops by the 20th of August. 3) The best studied transplanting season is supposed to be Feb. -April, for those transplanted during that period proved 100% of success. The next best transplanting season may be October. Rain fall does not have so much effect on transplanting as the growing season does. 4) In inducing the subterranean stems, the growing season can be ignored. The root expnsion is most animated during the months of April-June, the most active season for water absorption. Those stems induced during the winter proves more rapid growth. 5) The entire stand cutting shows greater growth than the reclaimed planting after burning and that, the growth is most vigorous during May-July, whereas during the hottest months of Aug-Sept. the growth shows only 5 cm. The new shoots grow slower both in the field of entire stand cutting and in the field of reclaimed planting after burning than in the otherwise fields.

  • PDF