• Title/Summary/Keyword: point defects

Search Result 497, Processing Time 0.025 seconds

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF

Study on Satellite Vibration Control using Adaptive Control Scheme

  • Oh, Se-Boung;Oh, Choong-Seok;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.6 no.2
    • /
    • pp.1-16
    • /
    • 2005
  • Adaptive control methods are studied for the Satellite to isolate vibration in spite of the nonlinear system dynamics and parameter uncertainties of disturbance. First, a centralized control scheme is developed based on the particle swarm optimization(PSO) algorithm and feedback theory to automatically tune controller gains. A simulation study of a 3 degree-of-freedom device was conducted to evaluate the performance of the proposed control scheme. Next, since a centralized control scheme is hard to construct model dynamics and not goad at performance when controller and systems environment are easily changed, a decentralized control scheme is presented to avoid these defects of the centralized control scheme from the point of view of production and maintenance. It is based on the adaptive control methodologies to find PID controller parameters. Experiment studies were conducted to apply the adaptive control scheme and evaluate the performance of the proposed control scheme with those of the conventional control schemes.

The Inner Pipeline Scanning Method by Digital Image Processing and Lens Combination (영상처리기법과 렌즈조합에 의한 관로내 탐사기법)

  • Kim, Won-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.1
    • /
    • pp.67-73
    • /
    • 2008
  • The most common method of pipeline inspection is to use a remote-controlled-machine equipped with a CCTV, which, however, has many limitations to accurately inspect pipeline condition. In case of a typical CCTV, since the camera looks at the end point of the pipe, the locations of the defects and distance-readings are often different. In addition, the quality and accuracy of the inspection is highly dependent on the operator's skill and experience. In this research a new system is developed by use of the image processing techniques and the lens combination. The image acquisition system is developed that acquires the front and the side view of the pipe simultaneously. Side view unwrapping and stitching technology using image process techniques are developed which delivers high resolution image data.

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

Dipole Distributions on a Hyperboloidal Panel (쌍곡면 패널에의 다이폴 분포)

  • Chang-Sup Lee;Jung-Chun Suh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.2
    • /
    • pp.32-42
    • /
    • 1995
  • When the thickness becomes so small as in the case of the trailing edge of the propeller blade or when the curvature of the surface varies rapidly as in ship stem, the existing panel method employing a flat-surface panel, obtained by collapsing the original non-planar surface into its mean location, suffers the leakage problem and also gives inaccurate induction upon the field point very close to the panel. The hyperboloidal panel deals with the induction from the dipole distributed on the non-planar surface without approximation, overcoming the defects of the flat-surface panel. This paper introduces two distinct derivations of the formulae to compute the integral for the potential induced by a dipole of uniform density distributed on a non-planar hyperboloidal surface element. One method is based on the Gauss-Bonnet theorem and the other is based on the transformation of the surface integral into a line integral.

  • PDF

A Study on the Inherent Defects in the eUCP Article 11 & Implication for the Revision (eUCP 11조의 잠재적 하자의 규명과 합리적 개정방안의 모색)

  • Kim, Ki-Sun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.35
    • /
    • pp.41-69
    • /
    • 2007
  • This study analyzes some important implications for the forthcoming revision of eUCP through the methodology of expected utility maximization theory. The overall results are as follows. First, beneficiary with an initial wealth has a risk-averse utility in traditional letter of credit transaction, and he would be more risk-averse in eUCP transaction. Secondly, the beneficiary who has risk-averse utility will pay for the risk premium to reduce the risk of corruption of an electronic record by means of cost of loss reduction activities. Thirdly, the cost of loss reduction activities is represented by a convex cost function, Fourthly, a risk averse beneficiary pursues loss reducing activities to the point where the expected marginal product of loss reduction is less than its marginal cost. Fifthly, a more risk-averse eUCP beneficiary will always select a higher level of loss reduction as long as the effectiveness of loss reduction is certain. Sixthly, when the effectiveness of loss reduction is uncertain, the more risk-averse eUCP beneficiary does not necessarily choose a higher level of loss reducing activities. Finally, it would be more reasonable that eUCP Article 11 should protect eUCP beneficiary who pursues a higher level of loss reducing activities.

  • PDF

Countermeasures for Preventing Electric Shock in Low-Voltage Handhole (저압 지중함에서 감전사고 방지를 위한 대책연구)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.195-200
    • /
    • 2007
  • This paper describes the countermeasures for preventing the electric shock which can be occurred in the low-voltage handhole underwater. Low-voltage handholes were designed and made for the test in the testing field. Which were installed 4 cases. a metal handhole cover was employed in case 1; FRP(Fiber glass Reinforced Plastic) handhole cover in case 2; an insulated rubber was put on the joint of the cables in case 3; the exposed conductors(cover, frame etc) were commoned and grounded in case 4. Thus, an ground potential near the low-voltage handhole was measured and evaluated quantitatively for the 4 cases. The measured results show that the potential of case 2.3 were lower than that of case 1 because the insulated rubber and the FRP cover prevented direct contact to the fault point. The case 4 is the lowest among the 4 cases because the common and grounding helps the fault current release into the ground, which makes the ground potential rise lower. As a result, although each case has the defects, these ways can effectively lower the electric shock risk in the low-voltage handhole.

Design of Moir${\acute{e}}$- and Starburst-Free Metal Meshes for Touch Screen Panels (모아레, 스타버스트 현상이 없는 터치스크린 패널용 메탈 메쉬 설계)

  • Shin, Dong-Kyun;Park, Jong-Woon;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.83-90
    • /
    • 2014
  • Using a ray tracing simulation, we have investigated the moir${\acute{e}}$ and starburst phenomena of touch screen panels (TSPs) based on opaque metallic grids (square, hexagonal, and random grids). It is demonstrated that employing a random metal mesh is the most effective way to suppress the moir${\acute{e}}$ and starburst phenomena at the same time. At high crossing angles between metal mesh of TSPs and black matrix (BM) of displays, however, a random metal mesh brings in stronger moir${\acute{e}}$ phenomenon than a square metal mesh due to point defects. Though the square metal mesh suppresses the moir${\acute{e}}$ effect substantially at high crossing angles, yet it results in the strongest starburst patterns. We have also provided the simulation scheme that can capture the moir${\acute{e}}$ and starburst patterns observed experimentally and useful design guidelines for metal grids.

A study on the inspection algorithm of FIC device in chip mounter (칩 마운터에의 FIC 부품 인식에 관한 연구)

  • Lyou, Kyoung;Moon, Yun-Shik;Kim, Kyoung-Min;Park, Gwi-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.384-391
    • /
    • 1998
  • When a device is mounted on the PCB, it is impossible to have zero defects due to many unpredictable problems. Among these problems, devices with bent corner leads due to mis-handling and which are not placed at a given point measured along the axis are principal problem in SMT(Surface Mounting Technology). It is obvious that given the complexity of the inspection task, the efficiency of a human inspection is questionable. Thus, new technologies for inspection of SMD(Surface Mounting Device) should be explored. An example of such technologies is the Automated Visual Inspection(AVI), wherein the vision system plays a key role to correct this problem. In implementing vision system, high-speed and high-precision are indispensable for practical purposes. In this paper, a new algorithm based on the Radon transform which uses a projection technique to inspect the FIC(Flat Integrated Circuit) device is proposed. The proposed algorithm is compared with other algorithms by measuring the position error(center and angle) and the processing time for the device image, characterized by line scan camera.

  • PDF

A Study on the Silicon Damages and Ultra-Low Energy Boron Ion Implantation using Classical Molecular Dynamics Simulation (고전 분자 동 역학 시뮬레이션을 이용한 실리콘 격자 손상과 극 저 에너지 붕소 이온 주입에 관한 연구)

  • 강정원;강유석;손명식;변기량;황호정
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.30-40
    • /
    • 1998
  • We have calculated ultra-low energy silicon-self ion implantations and silicon damages through classical molecular dynamics simulation using empirical potentials. We tested whether the recently developed Environment-Dependent Interatomic Potential(EDIP) was suitable for ultra low energy ion implantation simulation, and found that point defects formation energies were in good agreement with other theoretical calculations, but the calculated vacancy migration energy was overestimated. Most of the damages that are produced by collision cascades are concentrated into amorphous-like pockets. Also, We upgraded MDRANGE code for silicon ion implantation process simulation. We simulated ultra-low energy boron ion implantation, 200eV, 500eV, and 1000eV respectively, and calculated boron profiles with silicon substrate temperature and tilt angle. We investigated that below 1000eV, channeling effect must be considered.

  • PDF