• Title/Summary/Keyword: plating time

Search Result 296, Processing Time 0.027 seconds

Study on the Formation Mechanism of Hard Chrome Surface Morphology by Atomic Force Microscopy

  • Lee, B.K.;Park, Y.;Kim, Man;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.35-35
    • /
    • 2002
  • Atomic force microscopy was applied to study the formation and growth mechanism of thin chrome layers prepared under various pulse plating conditions. The chrome was electro-deposited from an electrolyte bath containing 250 gl-l of chromic acid, 25 gl-l of sulfuric acid using direct current density of $1.6{\;}mA.$\textrm{mm}^{-2} and pulse currents with on-off time from 5 to 900 ms. The higher current density enhanced nucleation rate which resulted in refining grain size. The chrome growth kinetics determining nodule size and shape significantly depends on the duration of on-time rather than duration of off-time and on/off time ratio.

  • PDF

The effect of TiN and coating parameters on the tool life extension (TiN 및 TiCN 코팅 특성이 공구수명에 미치는 영향에 대한 연구)

  • 백영남;정우창
    • Journal of Surface Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.317-324
    • /
    • 1998
  • TiN and TiCN films were deposited on the high speed steel by Cathode Arc Ion Plating(CAIP) Process to investigate the tool life extension effect. The experiment variables were bias voltage and deposit time for the TiN coating and reactive gas flow rate ($CH_4:N_2$) under fixing deposit pressure, are current, bias voltage for the TiCN coating respectively. The micro structure and mechanical properties were investigated and compared for among the coating conditions using various methods and machining practice.

  • PDF

A Polyphialidic Hyphomycete Gonytrichum macrocladum New to Korea from the Arable Soil in Jinju-shi

  • Lee, Seon-Ju;Go, Seung-Joo
    • Mycobiology
    • /
    • v.28 no.3
    • /
    • pp.127-129
    • /
    • 2000
  • During the study of soil mycoflora in Jinju-shi in 1997, a dematiaceous hyphomycete, Gonytrichum macrocladum, was isolated using the soil dilute plating method. The isolate was recovered with very low frequencies and recorded for the first time in Korea. illustrated descriptions are presented for the isolate examined in the present study.

  • PDF

Clinical Aspects among Platers (도금공(鍍金工)에 대한 임상적(臨床的) 관찰(觀察))

  • Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.16-24
    • /
    • 1977
  • This is a result of clinical examination for workers working with Chromic acid and Chromium compounds in the plating room of their companies. I selected two companies that the plating process and the kinds of plating were similar. One (SW Co.) was more or less improved the operating environment with the ventilation machine so on and another (SR Co.) did not it so. The former was examined at March 29th 1977, the latter was at June 28th 1976. But the respiratory communicable diseases, flue or common cold so on were not spreaded there at that time. The clinical aspects were compared between the group of SW, and SR. The swelling and hyperemic signs of nasal mucous membrane and the experience of nasal bleeding were about 50%, generally, in all the groups. The following problem was dizziness or vertigo. The nasal signs in the group of SW (improved ventilation of the room air) were relatively weak, but in another, it was some what severe; - there was necrotic sign with thick nasal clast. They were only used of gauze mask when the vapors of various solvents were deeply full in the room. And there was very high rate of bronchial signs, sputum or coughing in the group of SW improved ventilation so called, than another one. I suppose that it means chronic inflammatory change of the bronchial mucous membrane with deeper signs, due to the individual protectors were carelessly or not used according to the improving of the operating environment. Theses nasal signs mentioned the above were not nearly in the other groups had not been done the Chromium plating. The Status of RBC, Hb and Ht, of urine protein and urobilinogen were mostly in normal range. But the number of WBC was more or less showed with a positive correlation to the working duration.

  • PDF

Optimization of Electrolysis Using Sacrificial Electrode for the Treatment of Electroless Nickel Plating Wastewater (희생전극을 이용한 무전해 니켈 도금 폐수의 전기분해처리 최적화)

  • Kim, Young-Shin;Jeon, Byeong-Han;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.204-209
    • /
    • 2015
  • The effluent limit of nickel from electroplating wastewater has been strengthened from 5 mg/L to 3 mg/L from 2014. However, currently applied treatment process for nickel plating wastewater is unable to meet the effluent limit, most of the treatment concept conducted by treatment plant is dilution with other metal bearing wastewater. This can cause very significant impact to the environment of nickel contamination. With this connection, the feasibility test has been conducted with the use of electrolysis by using sacrificial electrodes. Experiments were conducted in synthetic and electroless nickel plating wastewater. Optimal condition of current density, pH were derived from the synthetic wastewater. It was found that the removal efficiency of nickel exceeded 94% at the operation condition of at pH 9 and the current density of $1{\sim}2mA/cm^2$. At this conditions, the iron sludge was generated very low amount. However, it was unsuccessful to meet the effluent limit by applying these treatment conditions to the real electroplating wastewater. This can be explained due to the matrix effect of other metals and anions contained real electroplating wastewater. From the result of further study, the optimal conditions for the real wastewater treatment were found out to be at pH 9, current density $6{\sim}7mA/cm^2$, for 5 minutes of operating time. At these conditions, 88% removal of nickel was achieved, which results the residual nickel concentration was below 3 mg/L.

A Study on Microstructure, Mechanical Properties, Friction and Adhesion of TiN Thin Films Coated on SKD61 and Radical Nitrided SKD61 Substrates by Arc Ion Plating (SKD61과 Radical Nitriding 처리된 SKD61 기판상에 Arc Ion Plating으로 증착된 TiN 박막의 미세구조 및 기계적 특성, 마찰 및 접착력에 관한 연구)

  • Joo, Yun-Kon;Yoon, Jae-Hong;Fang, Wei;Zhang, Shi-Hong;Cho, Tong-Yul;Ha, Sung-Sik
    • Journal of Surface Science and Engineering
    • /
    • v.40 no.6
    • /
    • pp.254-257
    • /
    • 2007
  • TiN coating on tool steel has been widely used for the improvement of durability of tools. In this work, radical nitriding(RN) is carried out on SKD61 at $450^{\circ}C$ for 5 hours in the ammonia gas pressure $2.7{\times}10^3\;Pa$. The TiN coating is carried out by arc ion plating(AIP) with the process parameters: arc power 150 A, bias voltage -50V, coating time 40 minutes and nitrogen gas pressure $4{\times}10^3\;Pa$. Hardness, elastic modulus, friction coefficient and adhesion of TiN coating on substrates of both TiN/SKD61 and TiN/RN SKD61 coatings are investigated comparatively. The primary crystalline faces of TiN surface are(200) and(111) for TiN/SKD61 and TiN/RN SKD61 respectively. In addition to the primary phase, Fe phase exists in TiN/SKD61 coating, but not in TIN/RN SKD61. The hardness of TiN/RN SKD61 is about 700 Hv, 250 Hv(56%) higher than that of TiN/SKD61 at the near interface of TiN and substrates. At the TiN surface, hardness of TiN/RN SKD61 is 2,149 Hv, 71 Hv(3%) higher than that of TiN/SKD61. The elastic modulus of TiN coating is improved to 26.7 GPa(6%) by radical nitriding. The adhesion is improved by the RN coating showing no spalling. buckling and chipping on the scratch test track which are shown on the non-RN TiN/SKD61.

Parameters Affecting the TiN Coated Machining Tool's Life (질화 티타늄이 코팅된 절삭공구의 수명에 영향을 미치는 인자)

  • 최병대;김동수
    • Journal of Surface Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.77-82
    • /
    • 1995
  • In this study, we examined the relationships between the coating film's properties, such as microhardness, adhesion of coating fil $m_strate, and machining tool's life time. Samples were prepared by coating TiN on the 5.5 diameter twist drills using reactive ion plating technology, For measuring microhardness and adhesion of fil $m_strate, HSS plate was used for substrate. TiN coated drill's life time was dependent on the adhesion of fil $m_strate and averagely increased by several ten times more than uncoated drill's. The major parameter affecting TiN coated drill's life time was the strong adhesion between coating film and substrate.ate.

  • PDF

Rates of Recovery of Enterobacter sakazakii (Cronobacter spp.) from Powdered Infant Formula Using Both a Chromogenic Agar and Real-Time PCR : A Preliminary Study

  • Song, Kwang-Young;Seo, Kun-Ho;Chon, Jung-Whan
    • Journal of Dairy Science and Biotechnology
    • /
    • v.39 no.3
    • /
    • pp.113-120
    • /
    • 2021
  • Although the number of incidences of illness caused by ingestion of the bacterial pathogen Enterobacter sakazakii (Cronobacter spp.) has dramatically declined, there remains a need for a robust isolation method to recover this microbe from powdered infant formula (PIF). The current method described in the FDA's Bacteriological Analytical Manual requires multiple steps, and 3-4+ days for complete analysis of PIF isolated E. sakazakii (Cronobacter spp.). We describe a bacteriological method including a one-step enrichment followed by plating on chromogenic agar for presumptive identification of E. sakazakii (Cronobacter spp.). Suspected colonies are confirmed by either biochemical analyses, or a Real-Time PCR-based assay. Using this method, E. sakazakii (Cronobacter spp.) in PIF can be isolated and identified within one day (24 hours).

Analysis of the Bacterial Community during the Storage of Gorosoe(Acer mono Max.) Sap (고로쇠 수액의 저장 중 세균군집 분석)

  • Oh, Jung-Hwan;Seo, Sang-Tae;Oh, Hye-Young;Hong, Jin-Sung;Kang, Ha-Young
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.4
    • /
    • pp.492-496
    • /
    • 2009
  • The composition of the bacterial populations in Gorosoe(Acer mono Max.) sap was characterized during storage with different heat treatments($63^{\circ}C$ for 30 min and $73^{\circ}C$ for 15 sec). The saps were aseptically collected at 0, 15 and 30 days of storage and analyzed by dilution plating and 16S rDNA PCR-DGGE analysis. There were significant differences in the total number of colony forming units(CFUs) of bacteria between heated and nonheated saps. Bacteria of nonheated sap were present at a level of $3.4{\times}10^7CFU/m{\ell}^{-1}$, whereas living bacteria were not detected in the heated sap. According to the 16S rDNA sequence and DGGE analysis, Pseudomonas sp. was the most abundant bacterial strain in the samlpes, and the bacterial community structures become more simplified with time and were composed of the Chryseobacterium sp. with time. These results allowed us to characterize the dominant bacteria involved in Gorosoe sap and to better understand their dynamics throughout storage.

Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation (도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구)

  • 이병규;신용철
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).