• Title/Summary/Keyword: plate-inserted

Search Result 162, Processing Time 0.027 seconds

Adaptive mesh refinement for 3-D hexahedral element mesh by iterative inserting zero-thickness element layers (무두께 요소층을 이용한 육면체 격자의 반복적 적응 격자 세분)

  • Park C. H.;Yang D. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.79-82
    • /
    • 2004
  • In this study, a new refinement technique for 3-dimensional hexahedral element mesh is proposed, which is aimed at the control of mesh density. With the proposed scheme the mesh is refined adaptively to the elemental error which is estimated by 'a posteriori' error estimator based on the energy norm. A desired accuracy of an analysis i.e. a limit of error defines the new desired mesh density map on the current mesh. To obtain the desired mesh density, the refinement procedure is repeated iteratively until no more elements to be refined exist. In the algorithm, at first the regions of mesh to be refined are defined and, then, the zero-thickness element layers are inserted into the interfaces between the regions. All the meshes in the regions, in which the zero-thickness layers are inserted, are to be regularized in order to improve the shape of the slender elements on the interfaces. This algorithm is tested on a simple shape of 2-d quadrilateral element mesh and 3-d hexahedral element mesh. A numerical example of elastic deformation of a plate with a hole shows the effectiveness of the proposed refinement scheme.

  • PDF

Evaluation of Ballistic Performance of Ceramic-Tile-Inserted Metal Block (세라믹 타일이 삽입된 금속 블록의 최적 방호구조 연구)

  • Lee, Seunghwan;Lee, Minhyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.297-304
    • /
    • 2016
  • A numerical simulation has been performed for the penetration of a long-rod penetrator into a metal block (ceramic-tile-inserted 4340-steel plate). The impact velocity is 1.5km/s at a normal incidence angle. The first two validations are conducted for a semi-infinite block measuring the depth of penetration (DOP). The material model of ceramic is the JH-2 (Johnson-Holmquist) model. The predicted DOP values are in close agreement with the experimental data. Then, the primary simulation is performed by varying the position of the confined ceramic tile for three types of thickness of ceramic tile. The residual velocity, residual mass and residual kinetic energy of the long-rod are obtained from the simulation. Based on these predicted values, the trend of the ballistic performance of the protective structure is estimated. In addition, the mass efficiency is calculated in order to determine the performance of the ceramic-tile-inserted metal block. Finally, the optimum protective structure is identified.

A STUDY OF THE KOREAN SINGLE VOWEL SOUND DISTORTION IN RELATION TO THE PALATAL PLATE THICKNESS -LINEAR PREDICTION CORRELATION AND LOG AREA RATIO ANALYSES BY COMPUTER- (구개상의 두께가 한국어 단모음 발음에 미치는 영향에 관한 연구 -컴퓨터를 이용한 선형 예측 분석과 LOG AREA RATIO 분석-)

  • Lee, Joung-Man;Choi, Dae-Gyun;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.31-49
    • /
    • 1988
  • This study was performed to investigate the sound distortion following the alternation of the palatal plate thickness, for this study, 3 subjects who were born in Seoul and spoke Seoul dialect were recruited from K university male student population. First, their sounds of /아(a)/, 어(e)/, 오(o)/, 우(u)/, 으($\.{+}$), 이(i)/,에(e)/ without inserting plate were recorded , and then the sounds with palatal plates of different thickness were recorded, respectively. The palatal plates was constructed to cover the alveolar & palatal surfaces of the maxilla with an approximate thickness of 1.0mm, 2.5mm, and thickness of 2.5mm over the alveolar ridge & 1.0mm elsewhere and, named B, C, D-type, in succession. Series of analysis were administered through Computer (16 bit IBM PC/AT) at analyze the sound distortions. These experiments were analyzed by the LPC, Log Area Ratio. The findings led to the following conclusions: 1. Sound distortions were relatively minute in each condition and informations, however, /이(i)/ was the most distorted vowel in all conditions. 2. By and large, sound distortion was large in C, D-types. However, there was no correlation of the distortion rate on the 3 informants, and all tested vowels. 3. It was similar to LPC, Log Area Ratio distortion rates. 4. It was found that the sound distortion wit]1 plate inserted was verified to the numeric value with LPC and Log Area Ratio method.

  • PDF

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.

Comparison of Sequelae According to the Types of Implants in Blow-Out Fracture (안와 파열 골절 치료 시 삽입물 종류에 따른 후유증 비교)

  • Kim, Tae-Gon;Im, Jong-Hyo;Lee, Jun-Ho;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: Blow out fracture can present tenderness, swelling, enophthalmos, extraoccular muscle limitation, paresthesia, diplopia according to severity of injury, so reconstruction of blow out fracture is important. Orbital soft tissue should be in orbit and defected orbital wall should be corrected by autologus tissue or alloplastic implants. Every implants have their merits and faults, every implants are used various. This study was designed to compare the sequelae of blow-out fracture repair using the alloplastic implants: micro-titanium mesh(Micro Dynamic titanium $mesh^{(R)}$, Leibinger, Germany), porous polyethylene ($Medpor^{(R)}$, Porex, USA), absorbable mesh plate(Biosorb $FX^{(R)}$ . Bionx Implants Ltd, Finland). Methods: Between January 2006 and April 2008, 52 patients were included in a retrospective study analysing the outcome of corrected inferior orbital wall fracture with various kind of implants. Implants were inserted through subciliary incision. Twenty patients were operated with micro-titanium mesh, fourteen patients with porous polyethylene and eighteen patients with absorbable mesh plate. In comparative category, enophthalmos, diplopia, range of motion of extraoccular muscle, inferior orbital nerve injury were more on frequently statistically in patients. Results: Fourteen of 18 patients underwent surgical repair to improve diplopia, 11 of 17 patients to improve parasthesia, 11 of 15 patients to improve enophthalmos, 8 of 9 patients to improve extraoccular muscle limitation. Duration of follow-up time ranged from 6 months to 12 months(mean, 7.4 months). There was no statistic difference of sequelae between micro titanium mesh and porous polyethylene and absorbable mesh plate in blowout fracture, inferior wall. Conclusion: There is no difference of sequelae between micro-titanium mesh, porous polyethylene and absorbable mesh plate in blow-out fracture, inferior wall. The other factors such as defect size, location, surgeon's technique, may influence the outcome of blow-out fracture repair.

Accurate Fastening of Blind Rivet Nuts: A Study (블라인드 리벳 너트 체결 적합성에 관한 연구)

  • Kim, C.;Gu, B.;Yi, S.;Choi, J.M.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.29 no.6
    • /
    • pp.331-337
    • /
    • 2020
  • Blind rivet nuts (BRNs) are increasingly used in automotive industry because unlike conventional bolt fastening, BRN fastening requires access from one side only. Generally, fastening is conducted using automated units, but manual fastening may be resorted to in case of small quantities. Since the fastening direction is not exactly perpendicular to the sheet metal, the BRN axis is tilted with respect to the plate and may result in damage or incomplete fastening. As the tilt angle (clamping angle α) increases, undesired plate deformation occurs and the contact area of the plate with the BRN fastening area decreases, reducing the clamping effect. In this study, the reduction of the clamping effect with the α was investigated to ensure stable fastening force. M6 BRNs were used in the tests. The fastening force was measured as follows: the plate was cut in half through the center of the hole; the BRN was inserted into the hole and fastened; and the clamping angle a was measured (values, 0° ≤ α ≤ 9°). The force leading to the separation of the halves was measured using a universal testing machine (UTM). The maximum α range, in which the fastening force remains stable, was determined. Finite element (FE) analysis confirmed that the fastening force decreases approximately linearly with increasing α. Based on the experiment and FE analysis using various α, the fastening force was found to decrease with α. Further, the maximum tolerance for α that provides secure fastening without damage is suggested.

Displacement Current in a Parallel Plate Capacitor Biased by DC Voltages (직류전압을 건 평행판 축전기에서 변위전류 고찰)

  • Kim, Jae-Dong;Jang, Taehun;Ha, Hye Jin;Sohn, Sang Ho
    • Journal of Science Education
    • /
    • v.45 no.2
    • /
    • pp.219-230
    • /
    • 2021
  • In this study, we derived several formulas for magnetic fields and induced voltages in a parallel plate capacitor biased by DC voltages. The computer simulation based on the derived formulas reveals that the magnetic fields due to the displacement current fall within the range of 10-10T to 10-9T and thence the experiment for the displacement current is not possible because the magnetic field sensor used in Data Logger could measure the magnetic fields of above 10-5T range. Contrary to this, the computer simulation confirms that the induced voltages in a toroidal coil due to the displacement current range measurable values of 0.002~0.021V. The results imply that the displacement current can be confirmed by measuring the induced voltages in a toroidal coil inserted into a parallel plate capacitor under DC biasing.

Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoid-splitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

  • Noh, Young-Min;Kim, Dong Ryul;Kim, Chul-Hong;Lee, Seung Yup
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.220-226
    • /
    • 2018
  • Background: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. Methods: From May 2014 to February 2016, 16 patients with displaced 3- or 4-part proximal humeral fractures were treated by application of a locking plate with an endosteal strut allograft via a deltoid splitting approach with a minimum follow-up of 12 months. The allograft was inserted through a fractured gap of the greater tuberosity to support the humeral head and then fixed by a locking plate with meticulous soft tissue dissection to protect the axillary nerve. Surgical outcomes were evaluated by the American Shoulder and Elbow Surgeons (ASES) and visual analogue scale (VAS) scores, radiological imaging, and clinical examination. Fixation failure on radiographs was defined as a >$5^{\circ}$ loss of neck shaft angle (NSA) compared to that on an immediate postoperative radiograph. Avascular necrosis (AVN) of the humeral head was also evaluated. Results: In all cases, complete union was achieved. The ASES and VAS scores were improved to $85.4{\pm}2.1$ and $3.2{\pm}1.3$, respectively. Twelve patients (75.0%) had greater than a $5^{\circ}$ change in NSA; the average NSA change was $3.8^{\circ}$. Five patients (31.3%) had unsatisfactory ranges of motion exhibiting a <$100^{\circ}$ active forward flexion. No axillary nerve injuries or AVN were observed at the last follow-up. One patient was converted to reverse total arthroplasty due to severe pain and functional deficit. Conclusions: Minimally invasive fixation via a locking compression plate and an endosteal fibula strut allograft in Neer classification 3-or 4-part fractures with severe osteoporosis in elderly patients can achieve good clinical results.

A Study on Reinforcing Effect of Multi-Bar Spring Nailing (다철근 스프링 네일링 공법의 보강효과 검토에 관한 연구)

  • Lee, Choong-Ho;Jung, Young-Jin;Kim, Dong-Sik;Chae, Young-Su
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.2
    • /
    • pp.147-169
    • /
    • 2007
  • This study investigates the reinforcing effects of the Multi-bar Spring nails with respect to the conventional Soil-nails in artificial slopes. Based on wide experience related to design and construction, soil nails have been widely applied to reinforce slope in the world. Multi-bar spring nails are one of the improved soil nailing methods. These method maximizes bending, shearing, pull-out resistance for those multi-nails, not unit nail, that are inserted in the borehole using special spacer at regular intervals. In addition, because cutting plane is confined effect resulting from a pressured plate at the end of the nails with compression spring equipment, slope stability is secured using MS-nailing method. Analyzing bending, pull-out, shearing condition of MS-nail, it was examined throughly elastic region, load transfer capacity, reinforcing effect on cutting plate of MS-nails. In addition, Pilot and laboratory tests, numerical analysis were carried out to verify the superiority of MS-nailing method. In case, MS nailing method is applied to reinforce artificial slope, it was analyzed that bending, pull-out, shearing resistance was increased more than existing nailing method was applied. In this study, it was shown that surface failure was more or less prevented using MS-nailing method, confining effect on cutting plane using spring stuck to flexible equipment.

  • PDF

Study on the Optical Performance of Evacuated Solar Collectors (진공복사관식 집열기의 성능실측 및 최적화 연구)

  • Chun, Won-Gee;Kang, Sang-Hoon;Kim, Ki-Hong;Lee, Yong-Kuk;Chang, Rae-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.63-71
    • /
    • 2001
  • This work has been carried out to find the ideal operating conditions for solar vacuum tube collectors which are widely used at present. Various types of solar collectors including a flat plate one were experimentally tested and examined to determine their thermal efficiencies and operating characteristics. Generally, solar vacuum tubes can be classified into two groups according to their design features. Of these, one is characterized by the insertion of a metallic device(such as a finned heat pipe) in an evacuated glass tube for the collection and transportation of solar energy. The other utilizes double glass tubes where the smaller one is contained inside the bigger one and soldered to each other after the small gap between them is evacuated. Both of these solar collectors are designed to minimize convection heat losses by removing the air which is in direct contact with the absorber surface. The performance of the former type can be readily analyzed by applying the relevant correlations developed for flat plate solar collectors. This has been demonstrated in the present study for the case of a solar collector where a heat pipe is inserted in an evacuated tube.

  • PDF