• Title/Summary/Keyword: plate-inserted

Search Result 162, Processing Time 0.029 seconds

Evaluation of Moment Resisting Post-Base Connection Using Multi-directional Connector (다방향 접합철물 삽입형 기둥-기초 접합부 모멘트 저항성능평가)

  • Kim, Keon-Ho;Lee, Sang-Joon
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.4
    • /
    • pp.331-337
    • /
    • 2014
  • The purpose of this paper is to evaluate the moment resistance of glulam post-to-base connections by applying quasi-static cyclic loads. The connectors consisted of inserted plates and drifted pins according to the load direction. The connection types employed in this study were total three including two unidirectional types (H, V) and the multi-directional type (M). The moment resistance of 8 mm-plate M-type is compared to 6 mm plate. Total four types of Post-to-base connection are prepared and tested under pseudo-static reversed cyclic loading. Test results showed that the yield moment of multi-directional connection is about 2 times higher than that uni-directional connections. The ductility ratio of multi-directional connection determined by EEEP was higher that that of uni-directional connection. It was becoming higher as the thickness of plate is increased. The Finite Element Analysis was conducted to estimate the stress distribution behavior of tested connections. Results showed the failure of multi-directional type were caused by the split of pined hole and the shear failure of lifted part of post.

  • PDF

Wide Band Bow-Tie Slot Antenna with Dual Reflector (듀얼 반사판을 이용한 광대역 보우타이 슬롯 안테나)

  • Lee Jae-Sung;Lee Sang-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.8
    • /
    • pp.1352-1358
    • /
    • 2006
  • In this paper, we have fabricated and tested a broad band bow-tie slot antenna with dual reflector. If we put 1/2 length thin and long slot on a wide metal plate, the slot antenna radiates efficient and strong radio wave as same as 1/2 dipole antenna does. we made with bow-tie form slot which has wider broad band than normal rectangular slot. At first, we made and test a single reflector slot antenna. To enlarge the broad band, we inserted another reflection plate between the slot antenna and reflection plate. After the test, we could have known that the low band(VSWR<2.0) has about $22%(793MHz\sim992MHz)$, high band(VSWR<2.0) has about 61% (1626MHz\sim3064MHz).

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Computational analysis of sandwich shield with free boundary inserted fabric at hypervelocity impact (비구속 삽입된 직물 섬유를 이용한 샌드위치 쉴드의 초고속 충격 해석)

  • Moon, Jin-Bum;Park, Yu-Rim;Son, Gil-Sang;Kim, Chun-Gon
    • Composites Research
    • /
    • v.24 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • In this paper, a novel hybrid composite shield to protect space structures from hypervelocity impact of micrometeoroid and space debris is proposed. The finite element model of the proposed shield was constructed and finite element analysis was conducted to approximate the energy absorption rate. Before the final model analysis, analysis of each component including the aluminum plate, PMMA plate, and intermediate layer of fabric was performed, verifying the finite element model of each component. The material properties used in the analyses were predicted material property values for high strain rates. The analysis results showed that, other than the fabric, the energy absorption rate of each component was in agreement. Afterwards, the finite element model of the hybrid composite shield was constructed, where it was analyzed for the restrained and unrestrained fabric boundary condition cases. Through the finite element analysis, the fiber pullout mechanism was realized for the hybrid shield with free boundary inserted fabric, and it was observed that this mechanism led to energy absorption increase.

Polarization Phase-shifting Technique for the Determination of a Transparent Thin Film's Thickness Using a Modified Sagnac Interferometer

  • Kaewon, Rapeepan;Pawong, Chutchai;Chitaree, Ratchapak;Bhatranand, Apichai
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.474-481
    • /
    • 2018
  • We propose a polarization phase-shifting technique to investigate the thickness of $Ta_2O_5$ thin films deposited on BK7 substrates, using a modified Sagnac interferometer. Incident light is split by a polarizing beam splitter into two orthogonal linearly polarized beams traveling in opposite directions, and a quarter-wave plate is inserted into the common path to create an unbalanced phase condition. The linearly polarized light beams are transformed into two circularly polarized beams by transmission through a quarter-wave plate placed at the output of the interferometer. The proposed setup, therefore, yields rotating polarized light that can be used to extract a relative phase via the self-reference system. A thin-film sample inserted into the cyclic path modifies the output signal, in terms of the phase retardation. This technique utilizes three phase-shifted intensities to evaluate the phase retardation via simple signal processing, without manual adjustment of the output polarizer, which subsequently allows the thin film's thickness to be determined. Experimental results show that the thicknesses obtained from the proposed setup are in good agreement with those acquired by a field-emission scanning electron microscope and a spectroscopic ellipsometer. Thus, the proposed interferometric arrangement can be utilized reliably for non-contact thickness measurements of transparent thin films and characterization of optical devices.

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

Pressure drop and heat transfer characteristics of a flat-plate solar collector with heat transfer enhancement device (열전달 향상 장치에 따른 평판형 태양열 집열기의 압력강하 및 열전달 특성)

  • Ahn, Sung-Hoo;Shin, Jee-Young;Son, Young-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.453-460
    • /
    • 2013
  • The surface roughness and heat transfer enhancement devices are known to increase the performance of a flat plate soar collector. This study includes the experiments on the effect of the several heat transfer enhancement devices inserted in duct to simulate the flat-plate solar collector. Experiment was basically at a constant heat flux on the upper duct wall. Inserted heat transfer enhancement devices are Chamfered rib $10^{\circ}$, Chamfered rib $20^{\circ}$, Rib & Groove and Rib & Dimple. Reynolds number is in the range of 2,300 to 22,000 which corresponds to turbulent regime. With the heat transfer enhancement devices, heat transfer would increase by the secondary flow and the increase of the heat transfer area. Pressure drop also increases with the insertion of the enhancement devices. Rib & Dimple model is the best in heat transfer enhancement, however, Chamfered rib $10^{\circ}$ model is the lowest in the pressure drop. Considering the heat transfer enhancement simultaneously with low pressure drop increase, performance factor was the best for the Chamfered rib $10^{\circ}$.

A Study on the Reduction of Scattered Ray in Outside Radiation Field (조사야 외부의 산란선량 감소 방법에 관한 연구)

  • Je, Jaeyong;Jang, Howon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.539-543
    • /
    • 2016
  • In this research, The way to decrease a patient's exposure dose by reducing the scattered radiation dosage outside a radiation field with an diagnosis X-ray was examined. The scattered radiation dosage reaching other parts outside the radiation field was to be reduced by attaching a self-produced $150{\times}190mm^2$ lead plate to the lower part of a collimator. When a lead plate was inserted additionally and the scattered radiation dosage of the X axis was measured in the direction of the central X-ray axis, It was found out to have been decreased by 26 to 36%, and in the direction of Y axis, which was vertical direction from the central axis, The scattered radiation dosage depending on whether a lead plate was used or not displayed no large differences. These results shows that the impact of the scattered radiation by the off focus X-ray that was generated around the focus was bigger than that generated by the shutter of the collimator. Therefore it has been concluded that installing an additional lead plate in the lower part of the existing collimator can decrease the scattered radiation dosage outside a radiation field.

Design of the Parabolic Reflector Antenna with Bended Elliptical Conductor Plate Feed (절곡된 타원형 도체평판 급전부를 갖는 포물선 반사판 안테나 설계)

  • Kim, Byung-Mun;Yun, Li-Ho;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.989-996
    • /
    • 2017
  • The proposed directional pencil beam antenna consists of a waveguide feeder with bended elliptical conductor plate feed and a parabolic curved reflector. Two rectangular apertures located at the broad wall near the end of the feed waveguide inserted from behind the reflector are located at the focus of the reflector and emit electromagnetic energy with bended elliptical conductor plate. This plate is designed to reflect electromagnetic energy primarily and to face the main reflector. The two rectangular apertures located at the waveguide end have inwardly protruding tabs for impedance matching of the antenna system, the shape of the tabs is a truncated oval. The proposed parabolic reflector antenna has a diameter of 400 mm and a focal length of 134.23 mm. The antenna gain is 33.68 dBi at the center frequency of 16.5 GHz, the beam width is $3.3^{\circ}$ and the reflection loss is -15 dB. Using the HFSS-IE, simulation results are performed to validate the proposed antennas.

The Removal of Plates after Craniomaxillofacial Surgery: A Retrospective Study (두개 악안면 수술 후 플레이트 제거에 관한 후향적 연구)

  • Park, Dae-Kyun;Yoo, Sang-Chul;Park, Seung-Ha;Koo, Sang-Hwan
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.186-190
    • /
    • 2007
  • Purpose: Plate systems have been used for osteosynthesis of cranial and oromaxillofacial fracture. However, there is no consensus on the need for routine removal of plate and the question about indications of removal. Therefore, we present the retrospective study to clarify the indications and consensus of removal. Methods: The medical records of patients who were treated with rigid internal fixation using plates after craniofacial trauma were reviewed. Study variables included age, gender, type of fracture, type of plate, seniority of the operator, causes of removal, and time between insertion and removal. All results amendable to statistics were analyzed using SPSS 10.0 to determine which set of variables might affect the fate of the plates. Results: For a period of 10 years (March 1, 1994 through July 31, 2004), total of 41 plates(6.7%) were removed among 609 plates inserted into 419 patients; 27 plates were removed from 15 patients for infection, which is the most common cause of removal accounting for 65.8%. Mean time between insertion and removal is 35.2 months and mean age is 41.4 years. Most plates were removed from combined fracture(14.92%) and facial fracture(8.47%) and these were statistically significant. The age, gender, seniority of the operator and other variables were not statistically associated with plate removal. Conclusion: This retrospective study shows that routine removal does not appear to be clinically indicated due to respectively low removal rate and that the commonest indications for removal were infection.