• 제목/요약/키워드: plate type heat exchanger

검색결과 129건 처리시간 0.029초

확관을 고려한 불균일 내면가공관의 전열특성 (Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.

종이 물성이 전열교환 엘리먼트 성능에 미치는 영향 (Effect of Paper Properties on the Performance of a Enthalpy Exchanger)

  • 김내현;조진표;송길섭;김동훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

배기 열 회수 열교환기 형식이 디젤 엔진 성능에 미치는 영향 (The effect of heat exchanger type for exhaust heat recovery system on diesel engine performance)

  • 김철정;최병철;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.639-647
    • /
    • 2014
  • 지구 온난화와 화석 연료 고갈로 인해 $CO_2$ 저감과 효율 상승을 동시에 만족하는 기술 개발이 요구된다. 배기 열 회수 기술은 두 가지를 모두 만족할 수 있는 대표적인 기술이다. 본 연구는 배기 열 회수 장치를 위한 세 가지 형식의 증발기용 열교환기를 배기관에 설치하여 실험 및 분석하였다. 고속최대부하에서 판형 열교환기의 배압이 가장 높아지고 실린더 최고 압력이 낮아지며 일산화탄소 배출량도 증가하였다. 또한 고속에서 배압이 2배 이상 증가하며 연료소비율이 2% 증가되어 열교환기 중 가장 높은 증가량을 나타내었다. 핀 튜브 열교환기는 전반적으로 배기 배출물이 적게 배출되고 연료소비율도 가장 적게 나타났다. 쉘 앤 튜브는 판형과 핀 튜브 성능의 중간정도이다. 엔진에 미치는 영향으로만 판단할 때 핀 튜브 열교환기가 배기 열 회수에 가장 적합한 열교환기로 판단된다.

균일유동에서 백연저감용 전열판 형태에 대한 열유동 특성 (Heat Flow Characteristics on Type of Heat Transfer Plate for White Smoke Reduction under Uniform Flow Condition)

  • 손준;차재민;왕쩐후안;권영철
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.591-596
    • /
    • 2016
  • 굴뚝의 백연을 줄이기 위하여 6종의 전열판을 선정하여 각각에 대한 열유동 특성을 연구하였다. 본 연구에서는 전열판의 열전달 성능(열전달 능력, 압력강하, 난류운동 에너지, 열전달계수 등)을 조사하기 위하여 상용 전산유체역학 프로그램인 ANSYS CFX Ver.14를 활용하여 균일유동 조건에서 수치해석을 수행하였다, 다른 유로구조를 가지는 6종의 전열판에 대한 전산해석으로부터 기본형, 사각형, 삼각형, 파형 열교환기의 열유동 과정이 모사되었다. 균일유동 해석으로부터 6종 열교환기들의 열전달 능력, 압력강하, 난류운동 에너지, 열전달계수들은 다른 경향을 보였으며, 유로 내의 열유동 특성은 주어진 유량, 전열판 형상, 종횡비에 좌우됨을 알 수 있었으며, 동일 파형에서는 종횡비가 낮을수록 열전달 성능이 우수하였다. 본 연구의 결과는 백연저감용 열교환기의 설계 기초자료로 활용될 것이다.

전산유체해석을 이용한 연구용원자로 수조수관리계통 열교환기 설계 및 수조수 온도 예측 (Design of the Heat Exchanger in Pool Water Management System of a Research Reactor and Estimation of the Pool Water Temperature Using CFD)

  • 정남균
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.45-51
    • /
    • 2016
  • 연구용원자로에서 여러 수조 및 일차냉각계통 내부에 존재하는 냉각재를 정화시키기 위해 설치되는 수조수관리계통은 일차냉각계통 펌프가 정지한 후 원자로에서 발생하는 노심 붕괴열을 제거한다. 또한, 작업수조 내의 조사물과 사용후핵연료저장조 내에 저장된 사용후핵연료에서 발생하는 열을 제거하여 수조수의 온도를 제한 값 이내로 유지하는 기능도 수행한다. 본 연구에서는 수조수관리계통의 설계와 운전 방법을 설계 초기단계에서 결정하기 위해서 상용프로그램인 Flowmaster를 이용한 전산해석방법으로 수조수관리계통의 열교환기를 설계하고, 각 수조수의 온도를 시간에 따라 예측하였다.

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

독립 핀-튜브 열교환기의 열전달 성능특성에 관한 연구 (Study on Heat Transfer Characteristics of Discrete Fin-and-tube Heat Exchangers)

  • 이호성;김용한;최종민;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.274-280
    • /
    • 2005
  • The objective of this study Is to investigate the heat transfer performance of plate discrete fin-and-tube heat exchangers with large fin pitch. In this study, twenty-two heat exchangers were tested with a variation of fin pitch, number of tube row, longitudinal tube pitch and fin alignment. Discrete fin type exchangers improved heat transfer performance more than 10% compared to tile continuous fin type heat exchangers. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row, The staggered fin alignment improved heat transfer performance more than 6% compared to the inline fin alignment. The effect of longitudinal tube pitch was insignificant on the j-factor and experiments found opposite effects on the j-factor with respect to fin alignment. Heat transfer correlations were developed from the measured data for flat plate discrete fin-and-tube heat exchangers with large fin pitch. The correlations yielded good predictions of the measured data with mean deviations of 1,4% and 0.3% for tire inline and staggered tube alignment, respectively.

  • PDF

TRNSYS 기반 무창기공형 공기식 집열 시스템 부프로그램 개발에 관한 연구 (Study on Development of Subroutine based on TRNSYS for Unglazed Transpired Air Collector System)

  • 박준언;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.81-90
    • /
    • 2003
  • UTAC(unglazed transpired air collector) system has unique advantage for space heating and tempering ventilation air over the conventional collector system such as flat plate and vacuum collector. UTAC can improve radiative and convective loss due to nonglazed component and enhanced plate surface configuration. and heating energy and its equivalent green house emission performance can be improved from the use of this like collector in building application. The Option D Calibration simulation approach of IPMVP(International Performance Measurement and Verification Protocol) in ESCO businesses has been recommended to use of the calibrated computer modules like these Energy-10. DOE2.1E and TRNSYS(transient system simulation). This study is to develop subroutine type-203 of TRNSYS15.2 program and appraise thermal performance of UTAC. With newely addeded subroutine type-203. 1) Thermal performance of unglazed transpired collector could be possible based on dimensionless variables such as efficiency and heat exchanger effectiveness. and 2) Assessement of energy consists of solar useful and insulation saving for UTAC could be possible.

Development of a Plate-Fin Type Gas Turbine Recuperator

  • Kwak Jae-Su;Yang In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1068-1076
    • /
    • 2006
  • A plate-fin type recuperator for a gas turbine/fuel cell hybrid power generation system was designed, manufactured, and tested. Performance analysis shows that the performance of the system is directly affected by the performance of the recuperator. Therefore, the recuperator should be designed and manufactured carefully, and its performance should be tested and verified before it is integrated into the system. In this paper, the developing procedure including designing, manufacturing, and testing of a cross flow plate-fin type recuperator was presented. Performance test results showed that the design requirements of the recuperator were almost satisfied. Based on the test results, improved design to reduce the size of the recuperator was suggested.

1차원 유동 네트워크 모델 및 다공성매질 모델을 이용한 판형 열교환기의 수치적 연구 (A Numerical Study on Plate-Type Heat Exchanger Using One-Dimensional Flow Network Model and Porous-Media Model)

  • 박재현;김민성;민준기;하만영
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.21-28
    • /
    • 2016
  • A typical heat exchanger, found in many industrial sites, is made up of a large number of unitary cells, which causes difficulties when carrying out full-scale three-dimensional numerical simulations of the heat exchanger to analyze the aero-thermal performance. In the present study, a three-dimensional numerical study using a porous media model was carried out to evaluate the performance of the heat exchanger modelled in two different ways : full-scale and simplified. The pressure drop in the air side and gas side along with the overall heat transfer rate were calculated using a porous media model and the results were then compared to results obtained with a one-dimensional flow network model. The comparison between the results for two different geometries obtained using a porous media model and a one-dimensional flow network model shows good agreement between the simplified geometry and the one-dimensional flow network model. The full-scale geometry shows reasonable differences caused by the geometry such as sudden expansion and contraction.