• Title/Summary/Keyword: plastic filter

Search Result 92, Processing Time 0.029 seconds

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Forward Gene Mutation Assay of Seven Benzophenone-type UV Filters using L5178Y Mouse Lymphoma Cell

  • Jeon, Hee-Kyung;Sarma, Sailendra Nath;Kim, Youn-Jung;Ryu, Jae-Chun
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • The effects of high energy short wave solar radiation on human skin have received much publicity as the major cause of accelerated skin ageing and of skin cancers. To meet public demand, the cosmetic industry has developed sun protection factor products, which contain a variety of so-called "UV filters", among others benzophenone (BP) and its metabolites are the widely used UV filters. UV filters are also used to prevent UV light from damaging scents and colors in a variety of cosmetics products and to protect of plastic products against light-induced degradation. There are many variants of BP in use. In this respect, to regulate and to evaluate the hazardous effect of BP-type UV filters will be important to environment and human health. The genotoxicity of 7 BP-type UV filters was evaluated in L5178Y $(tk^{+/-})$ mouse lymphoma cells in vitro. BP, benzhydrol, 4-hydroxybenzophenone 2-hydroxy-4-methoxybenzophenone and 2, 4-dihydroxybenzophenone did not induce significant mutation frequencies both in the presence and absence of metabolic activation system. 2, 2'-Dihydroxy-4-methoxybenzophenone appeared the positive results at the highest dose, i.e. 120.4 ${\mu}g/mL$ only in the absence of metabolic activation system. And also, 2, 3, 4-trihydroxybenzophenone revealed a significant increase of mutation frequencies in the range of 138.1-207.2 ${\mu}g/mL$ in the absence of metabolic activation system and 118.3-354.8 ${\mu}g/mL$ in the presence of metabolic activation system. Through the results of MLA with 7 BP-type UV filters in L5178Y cells in vitro, we may provide the important clues on the genotoxic potentials of these BP-type UV filters.

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

[Retraction]Characterization of carbon black nanoparticles using asymmetrical flow field-flow fractionation (AsFlFFF)

  • Kim, Kihyun;Lee, Seungho;Kim, Woonjung
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.77-87
    • /
    • 2019
  • High viscosity carbon black dispersions are used in various industrial fields such as color cosmetics, rubber, tire, plastic and color filter ink. However, carbon black particles are unstable to heat due to inherent characteristics, and it is very difficult to keep the quality of the product constant due to agglomeration of particles. In general, particle size analysis is performed by dynamic light scattering (DLS) during the dispersion process in order to select the optimum dispersant in the carbon black dispersion process. However, the existing low viscosity analysis provides reproducible particle distribution analysis results, but it is difficult to select the optimum dispersant because it is difficult to analyze the reproducible particle distribution at high viscosity. In this study, dynamic light scattering (DLS) and asymmetrical flow field-flow fractionation (AsFlFFF) analysis methods were compared for reproducible particle size analysis of high viscosity carbon black. First, the stability of carbon black dispersion was investigated by particle size analysis by DLS and AsFlFFF according to milling time, and the validity of analytical method for the selection of the optimum dispersant useful for carbon black dispersion was confirmed. The correlation between color and particle size of particles in high viscosity carbon black dispersion was investigated by using colorimeter. The particle size distribution from AsFlFFF was consistent with the colorimetric results. As a result, the correlation between AsFlFFF and colorimetric results confirmed the possibility of a strong analytical method for determining the appropriate dispersant and milling time in high viscosity carbon black dispersions. In addition, for nanoparticles with relatively broad particle size distributions such as carbon black, AsFlFFF has been found to provide a more accurate particle size distribution than DLS. This is because AsFlFFF, unlike DLS, can analyze each fraction by separating particles by size.

False positive and false negative reactions of acidic hydrogen peroxide for enhancing blood (Acidic hydrogen peroxide로 혈액을 증강할 때의 위양성 및 위음성 반응)

  • Lee, Wonyoung;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.124-128
    • /
    • 2022
  • Blood-sensitive reagents may exhibit false positives or negatives under the influence of substances other than blood. Since these reactions lead to the misinterpretation of blood evidence, it is essential to investigate the possibility of false-positive and -negative reactions of blood-sensitive reagents. Acidic hydrogen peroxide (AHP) is a recently discovered blood-sensitive reagent, and it is not yet known whether it causes false-positive or -negative reactions. To confirm this, 20 µL of blood was placed on metal surfaces, plastic surfaces, paper surfaces, paint surfaces, foods, vegetable oils, detergents, and petroleum hydrocarbons, and then AHP was applied. The blood was observed through an orange filter under a 505-nm light source, and no false-positive or false-negative reactions were observed with any of the substances/materials. However, it was confirmed that polyethylene terephthalate surfaces, polyvinylchloride surfaces, some paint surfaces, and foods exhibit their own photoluminescence under the conditions of blood observation, which interferes with blood observation.

Radiochemical Analysis of Filters Used During the Decommissioning of Research Reactors for Disposal

  • Kyungwon Suh;Jung Bo Yoo;Kwang-Soon Choi;Gi Yong Kim;Simon Oh;Kanghyun Yoo;Kwang Eun Lee;Shinkyoung Lee;Young Sang Lee;Hyeju Lee;Junhyuck Kim;Kyunghun Jung;Sora Choi;Tae-Hong Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.489-500
    • /
    • 2022
  • The decommissioning of nuclear facilities produces various types of radiologically contaminated waste. In addition, dismantlement activities, including cutting, packing, and clean-up at the facility site, result in secondary radioactive waste such as filters, resin, plastic, and clothing. Determining of the radionuclide content of this waste is an important step for the determination of a suitable management strategy including classification and disposal. In this work, we radiochemically characterized the radionuclide activities of filters used during the decommissioning of Korea Research Reactors (KRRs) 1 and 2. The results indicate that the filter samples contained mainly 3H (500-3,600 Bq·g-1), 14C (7.5-29 Bq·g-1), 55Fe (1.1- 7.1 Bq·g-1), 59Ni (0.60-1.0 Bq·g-1), 60Co (0.74-70 Bq·g-1), 63Ni (0.60-94 Bq·g-1), 90Sr (0.25-5.0 Bq·g-1), 137Cs (0.64-8.7 Bq·g-1), and 152Eu (0.19-2.9) Bq·g-1. In addition, the gross alpha radioactivity of the samples was measured to be between 0.32-1.1 Bq·g-1. The radionuclide concentrations were below the concentration limit stated in the low- and intermediatelevel waste acceptance criteria of the Nuclear Safety and Security Commission, and used for the disposal of the KRRs waste drums to a repository site.

Opening Size Determination of Geotextiles Using Dry and Wet Methods (건식/습식 방법을 이용한 토목섬유의 유효구멍크기 측정방법 평가)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • Dry and wet test methods established by Korean industrial standards to estimate opening size of 3 types of geotextile which are widely used for filter of plastic drain board in Korea are performed to evaluate characteristics of the test methods and to compare the test results. Judging from test results, dry method is a relatively poor test, having lots of problems causing many errors but a simple-quick test. Wet method is a very specific test avoiding many of the problems of dry method such as electrostatic charges, trapping in the geotextiles and so on. However, one of wet test methods, KS K ISO 12956, takes long time to complete a test and is too strict to handle loss of granular material. Generally, opening size of a geotextile by wet test method is smaller than that of dry test method. Especially, opening size by KS F 2126 which is called hydrodynamic method but at present is not used anymore is similar to or smaller than that by KS K ISO 12956 method.

Varietal Responses of Soybean Germination and Seedling Elongation to Temperature and Polyethylene Glycol Solution (온도와 PEG에 대한 대두품종의 발아 및 묘신장 반응)

  • Seong, Rak-Chun;Chung, Hae-Joon;Hong, Eun-Hi
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.1
    • /
    • pp.31-37
    • /
    • 1988
  • Germination and seedling elongation of soybeans [Glycine max. (L.) Merr., cults. Bangsakong, Hill, Paldalkong, Danyupkong, Baegwun-kong. Kwangkyokong, Changyupkong and Hwangkeumkong] were measured at two temperatures (15 and 30$^{\circ}C$) and four polyethylene glycol 10,000 (PEG) solutions (0, 20, 30 and 35g/100g-H$_2$O). Adjustments of PEG solution were based on water potentials of 0.0, -0.5, -1.1 and -1.5 MPa at room temperature. Observations were made at 3, 6, 9 and 12 days for 15$^{\circ}C$ and 1, 2, 3 and 4 days for 30$^{\circ}C$. Fifteen seeds of each cultivar were placed on Whatman No. 1 (9cm) filter paper in plastic pertridishes, and adjusted to 15 ml of the proper PEG solution supplemented with 0.2 percent thiram using automatic syringe. The dishes were covered with cap. The seeds were germinated at a continuous temperature of 15 or 30$^{\circ}C$ under dark conditions for programmed period. Seedling moisture content and seedling length of eight soybean cultivars decreased as PEG concentration increased both at 15 and 30$^{\circ}C$. Cultivar differences in seedling moisture content and seedling length were found among eight soybean cultivars at temperatures of 15 and 30$^{\circ}C$. Larger sized cultivar absorbed more moisture than samller sized cultivar. However, reverse results were obtained on the seedling moisture content of each of eight soybean cultivars. Cultiver Hill and Paldalkong showed greater seedling length than the other six cultivars from 20 to 30g/100g water of PEG concentrations both at 15 and 30$^{\circ}C$. The results of this study indicated that germination test of soybean seeds in aqueous solutions of PEG has potential for screening soybean cultivars for improved emergence during moisture stress.

  • PDF

Reliability and Accuracy of the Deployable Particulate Impact Sampler for Application to Spatial PM2.5 Sampling in Seoul, Korea (서울시 PM2.5 공간 샘플링을 위한 Deployable Particulate Impact Sampler의 성능 검증 연구)

  • Oh, Gyu-Lim;Heo, Jong-Bae;Yi, Seung-Muk;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.3
    • /
    • pp.277-288
    • /
    • 2017
  • Previous studies of health effects of $PM_{2.5}$ performed spatial monitoring campaigns to assess spatial variability of $PM_{2.5}$ across people's residences. Highly reliable portable and cost-effective samplers will be useful for such campaigns. This study aimed to investigate applicability of the Deployable Particulate Impact Sampler(DPIS), one of the compact impact samplers, to spatial monitoring campaigns of $PM_{2.5}$ in Seoul, Korea. The investigation focused on the consistency of $PM_{2.5}$ concentrations measured by DPISs compared to those by the Low-volume Cyclone sampler (LCS). LCS has operated at a fixed site in the Seoul National University Yeongeon campus, Seoul, Korea since 2003 and provided qualified $PM_{2.5}$ data. $PM_{2.5}$ sampling of DPISs was carried out at the same site from November 17, 2015 through February 3, 2016. $PM_{2.5}$ concentrations were quantified by the gravimetric method. Using a duplicated DPIS, we confirmed the reliability of DPIS by computing relative precision and mean square error-based R squared value ($R^2$). Relative precision was one minus the difference of measurements between two samplers relative to the sum. For accuracy, we compared $PM_{2.5}$ concentrations from four DPISs (DPIS_Tg, DPIS_To, DPIS_Qg, and DPIS_Qo) to those of LCS. Four samplers included two types of collection filters(Teflon, T; quartz, Q) and impaction discs(glass fiber filter, g; pre-oiled porous plastic disc, o). We assessed accuracy using accuracy value which is one minus the difference between DPIS and LCS $PM_{2.5}$ relative to LCS $PM_{2.5}$ in addition to $R^2$. DPIS showed high reliability (average precision=97.28%, $R^2=0.98$). Accuracy was generally high for all DPISs (average accuracy=83.78~88.88%, $R^2=0.89{\sim}0.93$) except for DPIS_Qg (77.35~78.35%, 0.82~0.84). Our results of high accuracy of DPIS compared to LCS suggested that DPIS will help the assessment of people's individual exposure to $PM_{2.5}$ in extensive spatial monitoring campaigns.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.