• Title/Summary/Keyword: plastic filter

Search Result 92, Processing Time 0.029 seconds

Competition Responses of Populus alba Clone ‘Bolleana’ to red:far-red light

  • Bae, Han-hong;Kang, Ho-duck;Richard B. Hall
    • Plant Resources
    • /
    • v.7 no.1
    • /
    • pp.77-86
    • /
    • 2004
  • The reduced ratio of red:far-red (R:FR) light acts as a measure of the proximity of competitors and plants can detect the potentially competing neighbor plants by perceiving reflected R:FR signals and initiate the response of “shade avoidance” before actual shading occurs. The phytochrome system is responsible for monitoring the changes in the R:FR and initiating the shade avoidance response. The response to low R:FR ratio was studied in a white aspen Populus alba clone ‘Bolleana’ using two filter systems: a clear plastic filter system that allows a R:FR ratio less than 1.0 to pass from adjacent border plant reflection; and a special commercial plastic that blocks FR light and creates a R:FR ratio above 3.0. The reduced R:FR signals enhanced the stem elongation in response to competition at the expense of relative stem diameter growth. Trees grown inside clear chambers were 27 % taller than trees grown inside the FR-blocking filter chambers. Stem taper of clear chamber trees was 16% less than the FR-blocking filter trees. Low R:FR also induced 22% more stem dry weight and 13% greater petiole length per leaf compared to the FR-blocking filter trees. There were no statistically significant differences in leaf area, leaf number increment, and total dry weight between the two light filter treatments.

  • PDF

The Ammonia Removal Capacity of a Few Kinds of Filter Media in a Water Reuse quaculture System (순환 여과식 양식 시설에 이용될 수종의 여과 재료의 효능에 관한 연구)

  • KIM In-Bae;KIM Pyong-Kih;CHEE Young-Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.561-567
    • /
    • 1987
  • The purpose of this study was to find out the removal capacity of harmful ammonia by different filter media in the submerged biological filters in a given space of chamber. Four materials, pile cloth, corrugated skylight roofing plate, embossed plastic plate, and gravel, were used as the experimental filter media. Each filter medium was placed in two aquariums, each aquarium measuring $90cm\times60cm\times60cm\;(depth)$. Under the normal operating condition, the average of mean ammonia removal rates during the first and second functioning periods by each filter material which occupied tile space in the filter chamber (aquarium) was as follows: 1. Pile cloth: $8.381\;g{\cdot}m^{-3}.\;day^{-1}$ 2. Corrugated skylight roofing plate: $7.834\;g{\cdot}m^{-3}.\;day^{-1}$ 3. Embossed plastic plate: $7.797\;g{\cdot}m^{-3}.\;day^{-1}$ 4. Gravel: $7.051\;g{\cdot}m^{-3}.\;day^{-1}$ Thus, there were no significant differences between the media, but at the time of practical application of these materials, some other factors such as investment cost, easiness for the removal of excess detritus accumulated in tile interstices of filter media, etc. should be fallen into consideration. When large units are required, in particular, removal of excess detritus from tile gravel bed is extremely difficult, and in case of pile cloth filters the installation work is much complicated and a problem in supporting the structure when drained also exists. In these respects, corrugated skylight roofing plate and embossed plastic plate seem to be more optimal, but again in practice the local situation for the availability and the price of the materials should be rechecked and the fitness of tile materials in the particular filter chambers under use or under consideration for construction must be taken into account.

  • PDF

Plastic LCDs for 2D-3D Convertible Mobile Phone Application

  • Kwon, Soon-Bum;Choi, Man-Seob;Park, Seo-Kyu;Kim, Wan-Su
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.293-296
    • /
    • 2004
  • We first report an application of plastic LCDs to 2D-3D convertible mobile phones. Plastic LCDs are proven to be most suitable solution for filter LCDs attached on main LCDs of 3D mobile phones in terms of quality and cost wises. The design and fabrication of plastic LCD filters are discussed in this paper.

  • PDF

A Study on Use and improvement of Construction type infiltration gallery (조립식 집수암거의 개량과 이용에 관한 연구)

  • 함준호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2593-2602
    • /
    • 1972
  • Plastic pipes Wrapped with synthetic filter are recently used for drainage or Collecting of Underground water. But it's use is possible only for small size of diameter less than 300mm, because large size plastic pipes are not readily availabe. For large diameter infiltration gallery, porous concrete pipes are now used, but it's heavy weight brings difficulties in making, moving and setting of the pipes. With it's conventional method of filter setting, fine sands are brought into the pipes to make trouble to lifting pumps and channels Therefore, initial construction cost and maintenance cost become high. To solve-this problem, new method is developed and tested. Small PVC pipes(diameter 14mm) are assembled at the site of construction to newly devised I beam type circls. The size of circular inpiltration gallery is optionally determined by I beam type circle which support small PVC pipes and is made of PVC amterial. This gallery are wrappd with syntheitc filter to prevent sand instruction. In this test, the diameter of 300, 400, 500mm were used. I beam type circles were made with PVC plated with thickness. t=6, 9, 12mm. Water quantity collected through the PVC circulor gallery are measured and the strengths of the gallery. 1. Allowable setting depth of gallery pipe below graund for the case of t=6mm, D=500mm is 2.72m. 2. Collected water quantity depends on soil texture, depth of water grandient of water surface, filter material angle of setting etc. 3. About 126% of water quantity collected from the one gallery pipe measured in two gallery pipes of two parallel installation.

  • PDF

A Study on the Flow Field Characteristics of Air Induction System for Reducing the Signal-to-Noise in the MAFS Output

  • Yoo, Seoung-Chool
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 2000
  • This study presents the flow visualization results, velocity and turbulence intensity measurements made within an air filter cover and entry region of a mass air flow sensor (MAFS) which is used in an induction system of 3.8L engine. Flow structure in two air filter cover assemblies were examined. The first was a clear plastic replica of the production cover while the second was a modified clear plastic cover with a geometry configured to reduce fluctuations. High speed flow visualization and laser doppler velocimetry (LDV) systems were used to reveal and analyze the flow field characteristics encountered in the sensor design process under steady flow conditions. A 40-watt copper vapor laser was used as a light source. Its beam is focused down to a sheet of light approximately 1.5mm thick. The light scattered off the particles was recorded by a 16mm high speed rotating prism camera at 5000 frames per second. A comparison of the flow patterns and LDV measurements in the original and modified air filter covers is presented to illustrate the controlling effect of the cover design on the turbulence structure formation near the bypass and on the sensor output signal. In both axial and radial planes of the main passage it was found that the turbulence flow pattern is remarkably influenced by the air filter cover and main passage configuration.

  • PDF

Acoustical Characteristics of Air Filter in the Engine Intake System (엔진 흡기계 공기 여과기의 음향 특성)

  • Kang, J.H.;Ih, J.G
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.190-193
    • /
    • 2005
  • The air filter in engine intake system filters the dirt in the breathing air but also it attenuates the noise although the phenomenon has been regarded negligible. For the analysis of the acoustical performance of air filter, an acoustical model is suggested in this paper. The air filter consists of a porous filter element, which catches the particulate dirt, and a plastic filter box, which supports the filter element. Fibrous structure of the filter element is modeled as a micro-perforated panel using the flow resistivity and porosity. The pleated geometry of the filter element is modeled as two coupled ducts and a mathematical model is developed for the analysis of sound propagation. The filter box Is modeled as a rigid rectangular box. By combining two models, a 4-pole transfer matrix for the air filter is derived. The transmission loss calculated using the transfer matrix of the suggested model is compared with the measured data. Reasonably good agreement is observed. The result can be improved by considering the visco-thermal effect in modeling, in particular at a frequency range near the troughs of TL curve.

  • PDF

Acoustic modeling of an air cleaner filter in the engine intake system (자동차 흡기계 공기 여과기 필터의 음향학적 모델)

  • Ih, Jeong-Guon;Kang, Jang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.114-117
    • /
    • 2006
  • The air filter in engine intake system has a function of filtrating the dirt in the scavenging air as well as attenuating the noise. The noise attenuation within the air cleaner filter, however, has been regarded as negligible by the field engineers. In this paper, for the analysis of the acoustical performance of air filter, an acoustical model was suggested and the characteristics of air filter system were investigated. Fibrous structure of the filter element was modeled as a micro-perforated panel using the flow resistivity and porosity. The pleated geometry of the filter element was modeled as two coupled ducts that have permeable walls, in which each duct area was assumed being constant. Using such simplified geometry, a mathematical model was developed for the sound propagation within a narrow duct system. Visco-thermal effect was considered in modeling the sound propagation through such tubes; the filter box was modeled as a rigid rectangular box. By combining two models, a four-pole transfer matrix was derived. For the validation purpose, transmission loss was measured for a plastic rectangular box containing an air filter. A noticeable effect of the air filter element was observed by including the filter into the box. Comparing the predicted and measured data, we found that the predicted TL agrees well with experimental results, in particular, in magnitude and frequency at TL troughs.

  • PDF

Optimizing the Injection Molding Process for Cooling Filter Using Computer Simulation and Taguchi Methods (컴퓨터 시뮬레이션과 다구치 방법을 이용한 냉각 필터 사출성형 공정의 최적화)

  • Lee, Seung-Hoon;Min, Byeong-Hyeon;Kim, Byeong-Gon
    • IE interfaces
    • /
    • v.15 no.3
    • /
    • pp.263-269
    • /
    • 2002
  • The injection molding process is a one of the most efficient techniques for manufacturing plastic parts of complex shape at low cost. In injection molding, molten plastic material is injected into the mold and cooled. Selection of molding conditions greatly affects the quality of molded parts. In this case study, we attempted to optimize the injection molding condition for a cooling filter using Taguchi experimental design methodology. The injection molding experiments were carried out using the Moldflow simulation software.

Removal characteristic on micropollutants as ibuprofen, acetaminophen, caffeine in small water fall system using HBC ring media (생물막 끈상여재를 이용한 낙차형태별 수중 미량유해물질 ibuprofen, acetaminophen, caffeine분해특성)

  • Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.129-135
    • /
    • 2009
  • PPCP (pharmaceuticals and personal care products) is known as micropollutant that is released from wastewater treatment plant. Research represents that these contaminants have increased in the last 10 years. This study tries to make four different trickling filter systems using plastic fiber media to remove PPCP such as acetaminophen, ibuprofen, caffeine. The results of the experiment that compares the process efficiencies of four different systems (A, B, C and D) using HBC media show that almost all the reactor has around 95% removal efficiency. Slope type HBC reactor has twice higher efficiency rather than submerged type reactor to remove PPCP in water system. In 8 hours, 89% of acetaminophen, ibuprofen, caffeine are removed in slope type reactor while 39% of them in submerged type.

Quality and Measure Controls for Plastic Board Drains Method (PBD공법의 품질 및 계측관리)

  • 박영목
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.133-145
    • /
    • 2001
  • This paper presents quality and measure controls of Plastic Board Drains(PBD) for improvement of soft ground. Laboratory and field tests has been carried out to evaluate the quality of PBD focussing on : discharge capacity of flow area; permeability of filter sleeve; migration of fine particles; deformed shape of PBD; consolidation of clay in the close vicinity of PBD; tensile strength of PBD; long-term consolidation behavior of clay-PBD. Test results show that the quality of PBD is sufficient to perform the improvement of soft silty and clayey ground. But, geotechnical engineer must make efforts minimizings of PBD damage and ground disturbance, continuity of drainage system during construction. Adequate monitoring system should apply at ground focussing on number, location, and accuracy of geotechnical instrumentation, measurement and evaluation of data for ground behaviour.

  • PDF