• Title/Summary/Keyword: plasma ion

Search Result 1,289, Processing Time 0.033 seconds

Effects of Hydroxide and Silicate ions on the Plasma Electrolytic Oxidation of AZ31 Mg Alloy (AZ31 마그네슘 합금의 플라즈마전해산화 피막 형성에 미치는 수산화 이온 및 규산 이온의 영향)

  • Moon, Sungmo;Yang, Cheolnam;Na, Sangjo
    • Journal of Surface Science and Engineering
    • /
    • v.47 no.4
    • /
    • pp.147-154
    • /
    • 2014
  • Formation behavior of PEO (Plasma Electrolytic Oxidation) films on AZ31 Mg alloy was studied in aqueous solutions containing various concentrations of hydroxide ion ($OH^-$) and silicate ion ($SiO_3{^{2-}}$) by voltage-time curves, and corrosion resistance of the PEO film-covered specimen was investigated by immersion test in 0.5 M NaCl solution. From the analyses of the voltage-time curves, it is suggested that two different types of anions are essentially needed for the formation of PEO films on AZ31 Mg alloy: film formation agent and local film breakdown agent. $SiO_3{^{2-}}$ ion acts only as a film formation agent but $OH^-$ ion acts not only as a film formation agent but also film breakdown agent. The PEO films prepared on AZ31 Mg alloy in alkaline silicate solution showed very good corrosion resistance without any pitting or filiform corrosions up to 480 h of immersion in 0.5 M NaCl.

Plasma Immersion Ion Implantation을 적용한 알루미늄합금의 방열 및 내부식특성에 관한 연구

  • Kim, Jeong-Hyo;Kim, Seung-Jin;Cha, Byeong-Cheol;Kim, Seon-Gwang;Son, Geun-Yong;Gwon, A-Ram
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.247-247
    • /
    • 2012
  • 기존형광등보다 에너지소비가 적고, 수명이 길다는 장점을 가진 LED소자는 조명분야뿐만 아니라 선박 및 해양플랜트시장에까지 적용분야가 확대되고 있다. 그러나 LED소자의 수명연장 및 제품신뢰성을 위해서 방열에 관한 연구가 필수적이며 특히, 해양환경적용을 위해서는 내부식성을 요구하는 방열 재료개발에 대한 연구가 필요하다. 일반적으로 방열판소재로 사용되는 알루미늄의 경우 열전도도가 우수하며, 대기 중에서 쉽게 생기는 자연산화막보다 내부식특성을 향상시키기 위해 현재 국내 외의 표면처리 방법으로 전기화학적 방법을 이용한 Anodizing기술을 적용하고 있다. 하지만, Anodizing에 사용되는 질산과 황산액을 처리하는 과정에서 유독물질을 발생시킴으로 유해물질사용제한 등 국제적으로 환경규제가 강화되고 있어 Anodizing기술의 적용이 제한적인 단점이 있다. 본 연구에서는 친환경적 기술인 Plasma Immersion Ion Implantation (PIII)방식을 사용하여 알루미늄표면에 $Al_2O_3$을 형성하였다. 최적의 산화막증착 조건을 찾기 위해 Gas Flow양, Pulse Voltage, 공정온도, 시간 등을 변수로 실험을 진행하였다. SIMS (Secondary ion mass spectroscopy)를 통해 $Al_2O_3$ 박막두께 및 Oxygen의 정량분석을 하였으며, Anodizing처리된 알루미늄시편과 열전도특성과 내부식특성을 비교하기 위해 각각 Hot Disk 열전도율측정기와 Salt water tester chamber를 사용하였다.

  • PDF

The Development of Cl-Plasma Etching Procedure for Si and SiO$_2$

  • Kim, Jong-Woo;Jung, Mi-Young;Park, Sung-Soo;Boo, Jin-Hyo
    • Journal of Surface Science and Engineering
    • /
    • v.34 no.5
    • /
    • pp.516-521
    • /
    • 2001
  • Dry etching of Si wafer and $SiO_2$ layers was performed using He/Cl$_2$ mixture plasma by diode-type reactive ion etcher (RIE) system. For Si etching, the Cl molecules react with the Si molecules on the surface and become chemically stable, indicating that the reactants need energetic ion bombardment. During the ion assisted desorption, energetic ions would damage the photoresist (PR) and produce the bad etch Si-profile. Moreover, we have examined the characteristics of the Cl-Si reaction system, and developed the new fabrication procedures with a $Cl_2$/He mixture for Si and $SiO_2$-etching. The developed novel fabrication procedure allows the RIE to be unexpensive and useful a Si deep etching system. Since the etch rate was proved to increase linearly with fHe and the selectivity of Si to $SiO_2$ etch rate was observed to be inversely proportional to fHe.

  • PDF

Determination of Clotiazepam in the Plasma Using Gas Chromatography/Mass Spectrometry with an Ion-Trap Detector and its Application to Pharmacokinetics in Healthy Volunteers

  • Kwon, Oh-Seung;Kim, Seung-Yong;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2006
  • A method determining the plasma concentration of clotiazepam was developed by using gas chromatography/mass spectrometry with an ion-trap detector and was validated for applying pharmacokinetics to human volunteers orally taken 5 mg dose of clotiazepam. The detection limit was 1 ng/ml and the limit of quantitation was 5 ng/mt. Intraday reproducibility and accuracy bias % were less than 8.2 and 10.2% with inter-day variations for those being within 7.0 and 13.8%, respectively. The recovery of clotiazepam was higher than 87%. The principal pharmacokinetic parameters were determined from the plasma concentration-time plot by non-compartmental or two-compartmental analysis. In non-compartmental analysis, the elimination half-life of 10.4 hr and the area under the curve of 651.3 ng hr/ml were determined, and the maximal concentration (158.6 ng/ml) in the plasma was obtained at 0.56 hr post-dose. The developed method can be appropriate to apply pharmacokinetics and bioequivalence of clotiazepam.

Work Function Changes on MgO Protective Layer after O2plasma Treatment from Ion-induced Secondary Electron Emission Coefficient (산소 플라즈마 처리후의 이차전자방출계수(γ)를 이용한 MgO 보호막의 일함수(φW) 변화)

  • Jeong, Jae-Cheon;Yu, SeGi;Cho, Jaewon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.3
    • /
    • pp.259-263
    • /
    • 2005
  • The changes in secondary electron emission coefficient(${\gamma}$) and work function($\Phi$$_{\omega}$) have been studied on the surface of MgO protective layer aster plasma(Ar. $O_2$) treatment using ${\gamma}$-focused ion beam (${\gamma}$-FIB) system. The values of ${\gamma}$ varied as follows: $O_2$-treated MgO > Ar-treated MgO > Non-treated MgO, and the work functions varied in the reverse order. The result indicates that both the physical etching and the chemical reaction of $O_2$-plasma removed the contaminating materials from the surface of MgO.

Characterization of a Micro-Laser-Plasma Electrostatic-Acceleration Hybrid-Thruster

  • Akira Igari;Masatoshi Kawakami;Hideyuki Horisawa;Kim, Itsuro ura
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.271-277
    • /
    • 2004
  • As one of the concepts of the laser/electric hybrid propulsion system, a feasibility study on possibilities of electrostatic acceleration of a laser ablation plasma induced from a solid target was conducted. Energy distributions of accelerated ions were measured by a Faraday cup. A time-of-flight measurement was also conducted for ion velocity measurement. It was found that an average speed of ions from a pure laser ablation in this case was about 20 km/sec for pulse energy of 40 $\mu$J/pulse with pulse width of 250 psec. On the other hand, through an electrostatic field with a + I ,000 V electrode, the speed could be accelerated up to 40 km/sec. It was shown that the electrode with positive potential was more effective than that with negative potential for positive-ion acceleration in laser induced plasma, or pulsed plasma, in which ions were induced with the Coulomb explosion following electrons. In addition, the ion-acceleration or deceleration strongly depended on conditions of pairs of inner diameter and electrodes gap.

  • PDF

PIII&D (Plasma immersion ion implantation & deposition) 기술을 이용하여 제조된 NbN 박막이 인공관절용 UHMWPE 소재의 마모에 미치는 영향 평가

  • Park, Won-Ung;Kim, Eun-Gyeom;Mun, Seon-U;Kim, Gyeong-Hun;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.228-228
    • /
    • 2012
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위하여 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 마모에 관여하여 인공관절의 수명에 영향을 미치게 되는데, 헤드 소재로서는 Co-Cr-Mo 합금이, 라이너 소재로서는 고분자 소재인 UHMWPE (Ultra High Molecular Weight Polyethylene)가 주로 사용되고 있다. 이러한 MOP (Metal-On-Polymer) 구조의 인공관절의 경우, 충격흡수의 장점이 있는 반면, 관절 운동시 발생하는 UHMWPE의 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재시술을 필요로 하게 된다. 또한 메탈 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 낮추는 또 하나의 요인이 되고 있다. 이러한 문제점들을 해결 하기 위하여, 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재 위에 niobium nitride (NbN) 박막을 증착하여 상대재인 UHMWPE의 마모를 줄이고자 하는 연구를 진행하였다. 마모량의 감소를 위하여, 박막을 증착하기 전에 Co-Cr-Mo 합금 위에 질소를 이온주입 하는 pre-ion implantation 공정을 도입하였으며, Co-Cr-Mo 합금과 NbN박막 사이의 접착력을 증가시키기 위하여 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. 실험 결과 pre-ion implantation 공정을 도입한 경우 현재 상용화 되어있는 Co-Cr-Mo 합금에 비하여 마모량을 2배 이상 감소시키는 것을 확인 할 수 있었으며, dynamic ion mixing 공정을 도입한 경우 장시간의 마모 시험에서도 UHMWPE의 마모량을 2배 가까이 줄일 수 있었다.

  • PDF

The Analysis of Fatigue Crack Initiation and Microstructure of Plasma Ion Nitrided SACM645 Steel (플라즈마 이온질화한 SACM645 강의 미세조직 및 피로균열 발생의 해석)

  • Kim, K.T.;Kwum, S.I.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.1
    • /
    • pp.69-77
    • /
    • 1996
  • The fatigue crack initiation behavior of plasma ion nitrided SACM645 steel was investigated through the rotary bending fatigue test and residual stress measurement by XRD. It was shown by XRD and EPMA that the plasma ion nitrided surface was composed of ${\gamma}^{\prime}(Fe_4N)$phase and ${\varepsilon}(Fe_{2-3}N)$phase, and that the nitrogen atoms existed in Fe matrix in diffusion layer. The OM, SEM and Auger spectroscopy showed that the depth of compound layer, mixed compound and diffusion layer, and diffusion layer was $8{\mu}m$, $30{\mu}m$ and $300{\mu}m$, respectively. However, the microhardness test showed that the depth of hardened layer was $500{\mu}m$. The tensile strength of the ion nitrided SACM645 was lower than that of the unnitrided SACM645, and the ion nitrided specimen was fractured without plastic deformation. The nitrided SACM645 showed much poorer low cycle fatigue properties than the unnitrided one. In rotary bending fatigue, the fatigue strength of the ion nitrided SACM645 was higher than that of the unnitrided specimen, and the fatigue crack initiation sites changed by applied fatigue stress levels. The XRD result showed that the ion nitrided SACM645 has the compressive residual stress from surface to $600{\mu}m$ deep and the tensile residual stress from $600{\mu}m$ to deeper site. It is thought that crack initiation takes place at the point where the total stress of residual stress and applied stress is maximum.

  • PDF

Ginsentology III;Identifications of Ginsenoside Interaction Sites for Ion Channel Regulation

  • Choi, Sun-Hye;Shin, Tae-Joon;Lee, Byung-Hwan;Lee, Jun-Ho;Hwang, Sung-Hee;Pyo, Mi-Kyung;Nah, Seung-Yeol
    • Journal of Ginseng Research
    • /
    • v.32 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • A ligand - whether an endogenous hormone, neurotransmitter, exogenous toxin or synthetic drug - binds to plasma membrane proteins (e.g., ion channels, receptors or other functional proteins) to exert its physiological or pharmacological effects. Ligands can also have functional groups, showing stereospecificity for interaction sites on their counterpart plasma membrane proteins. Previous reports have shown that the ginsenoside Rg$_3$, a bioactive ginsenoside, meets these criteria in that: 1) an aliphatic side chain of $Rg_3$ plays a role as a functional group, 2) Rg$_3$ regulates voltage- and ligand-gated ion channels in a stereospecific manner with respect to carbon-20, and 3) $Rg_3$ regulates subsets of ligand-gated and voltage-gated ion channels through specific interactions with identified amino acid residues inside the channel pore, in the outer pore entryway, or in toxin binding sites. Rg$_3$, therefore, could be a candidate for a novel ginseng-derived glycosidic ligand regulating ion channels and receptors. This review will examine how Rg$_3$ regulates voltage-gated and ligand-gated ion channels through interactions with its target proteins in the plasma membrane. Hopefully, this review will advance understanding of ginseng pharmacology at the cellular and molecular levels.

Development of Large-Area RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Chang, Doo-Hee;Jeong, Seung Ho;Kim, Tae-Seong;Park, Min;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.179.2-179.2
    • /
    • 2013
  • A large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER device. Negative hydrogen ion sources are major components of neutral beam injection (NBI) systems in future large-scale fusion experiments such as ITER and DEMO. The RF sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck-Institute for Plasma Physics), Garching, for the ASDEX-U and W7-AS neutral beam heating systems. Ion sources of the first NBI system (NBI-1) for the KSTAR tokamak have been developed successfully with a bucket plasma generator based on the filament arc discharge, which have contributed to achieve a good plasma performance such as 15 sec H-mode operation with an injection of 3.5 MW NB power. There is a development plan of RF ion source at the KAERI to extract the positive ions, which can be used for the second NBI system (NBI-2) of the KSTAR and to extract the negative ions for future fusion devices such as Fusion Neutron Source and Korea-DEMO. The development progresses of RF ion source at the KAERI are described in this presentation.

  • PDF