• 제목/요약/키워드: plasma ion

검색결과 1,286건 처리시간 0.029초

박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구 (A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS)

  • 김형우;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

유전자재조합 단백질 회수 공정에서의 고체상 재접힘 기술: 여러 바이오의약 단백질에의 적용 사례 (Solid-Phase Refolding Technology in Recombinant Proteins Recovery: Application Examples to Various Biopharmaceutical Proteins)

  • 김민영;서창우;김창성;조태훈;박상중;최원찬;이은규
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.187-201
    • /
    • 2005
  • 최근 전통적인 액체상 공정을 대체하는 기술로서 고체 담체와 단백질 사이의 '생물인식' 기능을 이용하는 새로운 생물공정기술이 개발되고 있다. 통상 고체 담체로는 표면에 특정한 기능기가 노출되어 있는 크로마토그래피용 담체를 사용한다. 단백질의 반응이나 상호작용이 단백질이 담체 표면에 부착되어 있는 상태에서 일어나기 때문에 이 '고체상 기술'은 액체상 기술에 비해 뚜렷한 장점을 갖고 있다. 고체상 재접힘은 변성제에 의해 용해된 내포체 형태의 재조합 단백질을 이온교환수지 표면에 흡착시켜 시작한다. 변성제를 단백질 주위로부터 서서히 제거시키면서 고유의 3차 구조로 재접힘시킨다. 재접힘이 완료되면 염 구배와 같은 전통적인 방법에 의해 재접힘된 단백질을 정제된 상태로 용출시킨다. 이 개념은 '확장층 흡착 재접힘'에도 연장 적용된다. 세포파쇄액에 변성제를 첨가하여 용해한 내포체 단백질은 확장층 흡착 크로마토그래피용 Streamline 담체에 흡착되고 세포찌꺼기와 불순 단백질들은 확장층 사이로 빠져 칼럼 밖으로 제거된다. 흡착된 목적 단백질은 고체상 재접힘 방법에 의해 재접힘 된 후 용출된다. 수년간 연구 발전되어 온이 새로운 재접힘 기술은 정제수율 향상, 공정 단계 감축, 공정 시간 및 부피 감소에 따라 생물의약공정의 경제성을 크게 향상시킬 수 있는 것으로 증명되고 있다. 본 논문에서는 실험실에서 수행한 여러 생물의약용 단백질들을 대상으로 한 연구 실험 자료를 바탕으로 고체상 재접힘 기술의 적용 사례를 서술하였다.

치과기공소 주조체 산세척과정에서 발생하는 폐수내 중금속 농도 (A Study on Heavy Metal Concentrations in Waste Water Produced in the Casting Pickling Process at Dental Technical Laboratories)

  • 정다이;사공준
    • 한국환경보건학회지
    • /
    • 제44권1호
    • /
    • pp.55-62
    • /
    • 2018
  • Objectives: This study set out to measure the heavy metal concentrations in waste water produced in the casting pickling process at dental technical laboratories and examine the actual state of its treatment. Methods:The investigator measured the concentrations of each heavy metal at 55 dental technical laboratories using an inductively coupled plasma optical emission system. Results: The annual usage of electrolytes was under 10 L in 50 (90.9%), and was 10L or more in five (9.1%) laboratories. Among the laboratories, 15 (27.3%) commissioned the treatment of waste,12 (21.8%) treated the waste with general sewage,and 28 (50.9%) treated the waste in aseptic tank. The arithmetic $mean{\pm}standard$ deviation and the geometric mean of chrome(Cr) were $75.3{\pm}50.9$ and 58.3 mg/L; those of cobalt (Co) were $112.3{\pm}106.7$ and 66.1 mg/L; those of nickel (Ni) were $62.9{\pm}83.5$ and 8.9 mg/L; those of molybdenum (Mo) were $17.1{\pm}13.4$ and 12.0 mg/L; those of iron (Fe) were $31.5{\pm}44.1$ and 6.2 mg/L; those of lead (Pb) were $0.3{\pm}0.3$ and 0.3 mg/L; those of beryllium (Be) were $3.6{\pm}3.6$ and 2.0 mg/L. The hydrogen ion concentration was under pH 2 across all the samples. Conclusions: The findings show that the dental technical laboratories were not doing well with the separation, storage, collection, and treatment of the electrolytes they discarded, and that most of the electrolytes were introduced through the general sewage or aseptic tank. The causes of this include alack of perception among the practitioners at dental technical laboratories and contracted companies avoiding collection for economic reasons. There is a need for education to improve the perceptions of waste water treatment among the practitioners at dental technical laboratories. Environment-related departments should be stricter with legal applications in the central and local governments. It is also required to provide proper management of commissioned treatment.

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Tandem Mass Spectrometric Analysis for Disorders in Amino, Organic and Fatty Acid Metabolism : 2 Years of SCL Experience in Korea

  • Yoon, Hye-Ran;Lee, Kyung Ryul
    • 대한유전성대사질환학회지
    • /
    • 제3권1호
    • /
    • pp.86-93
    • /
    • 2003
  • Background : The SCL began screening of newborns and high risk group blood spots with tandem mass spectrometry (MS/MS) in April 2001. Our goal was to determine approximate prevalence of metabolic disorders, optimization of decision criteria for estimation of preventive effect with early diagnosis. This report describes the ongoing effort to identify more than 30 metabolic disorders by MS/MS in South Korea. Methods : Blood spot was collected from day 2 to 30 (mostly from day 2 to 10) after birth for newborn. Blood spot of high risk group was from the pediatric patients in NICU, developmental delay, mental retardation, strong family history of metabolic disorders. One punch (3.2 mm ID) of dried blood spots was extracted with $150{\mu}L$ of methanol containing isotopically labelled amino acids (AA) and acylcarnitines (AC) internal standards. Butanolic HCl was added and incubated at $65^{\circ}C$ for 15 min. The butylated extract was introduced into the inlet of MS/MS. Neutral loss of m/z 102 and parent ion mode of m/z 85 were set for the analyses of AA and AC, respectively. Diagnosis was confirmed by repeating acylcarnitine profile, urine organic acid and plasma amino acid analysis, direct enzyme assay, or molecular testing. Results : Approximately 31,000 neonates and children were screened and the estimated prevalence (newborn/high risk group), sensitivity, specificity and recall rate amounted to 1:2384/1:2066, 96.55%, 99.98%, and 0.73%, respectively. Confirmed 28 (0.09%) multiple metabolic disorders (newborn/high risk) were as follows; 13 amino acid disorders [classical PKU (3/4), BH4 deficient-hyperphenylalaninemia (0/1), Citrullinemia (1/0), Homocystinuria (0/2), Hypermethioninemia (0/1), Tyrosinemia (1/0)], 8 organic acidurias [Propionic aciduria (2/1), Methylmalonic aciduria (0/1), Isovaleric aciduria (1/1), 3-methylcrotonylglycineuria (1/0), Glutaric aciduria type1 (1/0)], 7 fatty acid oxidation disorders [LCHAD def. (2/2), Mitochondrial TFP def. (0/1), VLCAD def. (1/0), LC3KT def. (0/1). Conclnsion : The relatively normal development of 10 patients with metabolic disorders among newborns (except for the expired) demonstrates the usefulness of newborn screening by MS/MS for early diagnosis and medical intervention. However, close coordination between the MS/MS screening laboratory and the metabolic clinic/biochmical geneticists is needed to determine proper decision of screening parameters, confirmation diagnosis, follow-up scheme and additional tests.

  • PDF

복숭아 품종별 핵과 종자의 항염증 및 항산화 효과간의 상관관계 (In vitro correlation between anti-inflammatory and anti-oxidant effects of stone and seed of peaches cultivars)

  • 정경미;백승화
    • 한국식품저장유통학회지
    • /
    • 제25권1호
    • /
    • pp.90-97
    • /
    • 2018
  • 본 연구에서는 현재 재배되고 있는 복숭아 품종 중 미황, 가납암백도 및 천홍의 핵과 종자를 이용하여 항산화 및 항염증 활성에 관한 연구를 하였다. 총 phenol 및 flavonoid 함량은 3품종 모두 종자에 비해 핵에서 월등히 높았으며, 품종간에는 천홍의 핵에서 가장 높은 함량을 나타내었다. DPPH radical 소거능과 FRAP 및 CUPRAC에 의한 항산화 활성은 3품종 모두 종자에 비해 핵에서 활성이 높았고, DPPH radical 소거활성은 가납암백도와 천홍, FRAP 활성은 천홍, CUPRAC 활성은 가납암백도에서 유의성 있게 높았다. NO 생성 억제 효과는 RAW 264.7 세포의 경우 핵 추출물에서 가납암백도 74%, 미황 70%, 천홍 58%이며, BV2 세포의 경우 미황 90%, 가납암백도 78%, 천홍 65%로 각각 염증 반응을 감소시켰다. 복숭아 3품종 핵과 종자의 총 phenol 함량과 총 flavonoid 함량은 높은 상관 관계를 나타내었고, 항산화 활성간의 상관성은 모두 유의적인 관계가 확인되었으나, 항염 활성과 항산화 활성, 항염 활성과 총 phenol 및 flavonoid 함량간은 낮은 상관관계를 나타내었다.

석개재 지역 하부 막골층 탄산염암의 광물조성, 미세구조 및 지화학적 특성 (Mineralogical, Micro-textural, and Geochemical Characteristics for the Carbonate Rocks of the Lower Makgol Formation in Seokgaejae Section)

  • 박채원;김하;송윤구
    • 자원환경지질
    • /
    • 제51권4호
    • /
    • pp.323-343
    • /
    • 2018
  • 본 연구에서는 석개재 지역 하부 막골층 탄산염암을 대상으로 광물조성, 미세구조 및 지화학적 특성을 분석하고 퇴적 환경에 영향을 준 유체의 특성에 대해 고찰해보았다. X-선 회절을 이용한 광물 정량 분석, SEM-BSE를 이용한 미세구조 분석에 근거하여 막골층 최하부와 하부의 탄산염암 미세구조를 4가지 Type으로 분류하고, EPMA 및 LA-ICP-MS를 이용해 각 Type 내 탄산염광물을 대상으로 주원소 및 미량원소를 분석하여 비교하였다. 다양한 크기의 반자형에서 타형의 돌로마이트 결정이 치밀하게 맞물린 구조를 갖는 Type 1과 다양한 크기의 자형에서 반자형의 돌로마이트 결정이 치밀하게 맞물린 구조를 갖는 Type 2의 돌로마이트는 상대적으로 높은 Mg/Ca ratio, 평평한 기울기의 REE 패턴, 낮은 또는 중간 이하의 Fe 함량, 낮은 Mn 함량 특성을 가진다. 돌로마이트가 광범위하고 치밀하게 맞물린 구조로 나타나는 것은 고염수로부터 지속적인 Mg 유입의 가능성을 지시한다. 반면, 세립질의 자형에서 타형의 돌로마이트 결정이 산재된 특성을 보이는 Type 3와 다양한 크기의 자형에서 반자형의 돌로마이트 결정을 갖는 Type 4는 Type 1, 2에 비해 돌로마이트 결정의 미세구조가 덜 치밀하게 맞물린 형태를 가진다. 또한 상대적으로 낮은 Mg/Ca ratio, MREE가 부화된 패턴, 중간 이상의 또는 높은 Fe 및 Mn 함량 특성을 가진다. 부분적인 돌로마이트화와 덜 치밀하게 맞물린 구조가 관찰되는 것은 해수와 염수의 혼합수 환경에서 Mg의 제한적인 유입을 지시한다. 또한 Type 4에서 나타나는 철함유 광물과 돌로마이트 결정에서 관찰되는 재결정화와 상대적으로 높은 Fe, Mn 함량을 갖는 특성은 속성 유체의 영향과 아산화 환경에 노출되면서 돌로마이트가 재결정화 작용을 받았을 가능성을 제시한다. 막골층 최하부와 하부의 주구성광물인 돌로마이트와 방해석의 광물학적, 미세구조적, 지화학적 분석을 종합한 결과, 최하부는 고염분의 대규모 퇴적수 영향을 받았고 하부는 담수와 해수의 혼합수 환경에서 속성 유체 영향을 받았음을 뒷받침한다.

Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰 (A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume)

  • 김진구;함준철;오신현;강천구;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.20-26
    • /
    • 2020
  • 핵의학이란 방사성동위원소 추적자를 인체에 투여하여 관심장기에 대한 형태학적인 정보와 생물학적이고 기능적인 정보를 얻고 평가한다. Dose calibrator는 의료기관에서 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이며, 방사성동위원소의 정확한 용량의 투여는 진단과 치료에 중요한 요인이다. 최근 정량분석을 위한 여러 시스템이 개발되고 있고 ERPF (Effective Renal Plasma Flow), GFR (Glomerular Filtration Rate) 등 정량분석이 필요한 검사에 있어서 정확한 투여 용량 및 재현성 있는 측정이 중요해지고 있다. 따라서 본 논문을 통해 Dose calibrator의 측정 깊이와 용량에 따른 선량 값의 성향을 알아보고 적절한 측정 깊이 및 용량에 대해 알아 보고자 한다. 실험에 사용한 Dose calibrator는 CRC-15R과 CRC-15βeta (Capintec, New Jersey, USA)를 사용하였다. 선원으로는 표준선원(Standard source) 137Cs, 133Ba, 57Co를 사용하였고, 방사성 의약품은 99mTc-pertechnetate를 사용하였다. 표준선원은 측정 깊이만 변화하여 0 cm부터 15 cm까지 1 cm 깊이마다 15회씩 측정했고, 99mTc-pertechnetate의 경우에는 1 mL 주사기로 표준선원과 동일한 깊이로 실험을 진행했고, 용량의 변화를 고려하여 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL로 각 깊이마다 15회씩 측정했다. 표준선원인 137Cs, 133Ba, 57Co의 깊이의 변화에서는 모두 깊이에 따른 선량 값의 변화가 통계적으로 유의한 차이가 있었다(p<0.05). 99mTc-pertechnetate도 깊이에 따른 용량의 변화에서 선량 값이 모두 통계적으로 유의한 차이가 있었다(p<0.05). CRC-15R의 표준선원 비교 그래프에서 137Cs, 133Ba, 57Co는 Plateau를 그리기 시작한 2 cm에서 9 cm까지는 각 선원마다 비교시 통계적으로 유의한 차이가 없었다(p>0.05). CRC-15βeta의 표준선원 비교 그래프에서는 Plateau를 그리기 시작한 영역은 3 cm에서 9 cm로 통계적으로 유의한 차이가 없었다(p>0.05). 99mTc-pertechnetate의 그래프는 0.1 mL에서 1 cm에서 7 cm, 0.3 mL와 0.5 mL에서는 0 cm에서 7 cm, 0.7 mL에서는 0 cm에서 6 cm, 0.9 mL에서는 0 cm에서 5 cm에서 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 본 연구를 통해 방사성동위원소를 환자에게 주입하거나 정도관리를 진행 시 편차가 적고 재현성을 위해 신뢰할 수 있는 구간을 확인 할 수 있었다. 높이에 따른 변화가 가장 적은 Plateau의 구간이 0.3 mL 혹은 0.5 mL의 용량으로 0 cm 에서 7 cm의 깊이에서 측정한다면, 편차를 최소한으로 줄일 수 있을 것으로 사료된다. 표준선원의 경우에는 본 연구의 결과에 따라 장비마다 Plateau의 변화가 가장 적은 구간의 깊이에서 재현성 있게 측정하는 것이 중요하다고 생각된다. 적절한 구간을 찾아서 재현성 있는 검사를 시행하면 검사의 품질향상 및 피폭선량저감 그리고 진단능을 높이는데 이바지 할 것이라고 생각된다.

CIGSe2 박막태양전지용 Mo 하부전극의 물리·전기적 특성 연구 (A Study of Mo Back Electrode for CIGSe2 Thin Film Solar Cell)

  • 최승훈;박중진;윤정오;홍영호;김인수
    • 한국진공학회지
    • /
    • 제21권3호
    • /
    • pp.142-150
    • /
    • 2012
  • CIGS 박막 태양전지 기판소재인 소다라임유리 표면에 플라즈마 전처리 후 DC 마그네트론 스퍼터링 방법으로 Mo 박막을 제조하였다. 증착압력과 증착시간 변화에 따른 Mo 박막의 물리적, 전기적 특성을 분석하였고, 셀렌화 처리 조건에 따른 $MoSe_2$ 생성 여부와 경향성을 연구하였으며, Mo 박막 두께에 따른 AZO/i-ZnO/CdS/CIGS/Mo/SLG 구조의 태양전지를 제조하여 그 특성을 분석 및 평가하였다. 증착압력이 4.9 mTorr에서 1.3 mTorr로 감소할수록 치밀하고 결정입자 사이의 공극이 적고, 증착속도가 감소하고 전기저항도가 낮은 Mo 박막이 증착되었다. 증착온도가 상온에서 $200^{\circ}C$로 증가할수록 Mo 박막은 치밀한 구조를 가지고 결정성은 향상되어 면저항이 낮게 나타났다. 셀렌화 시간이 길어질수록 Mo 박막 층은 줄어들고, $MoSe_2$ 층 생성두께가 커지는 것을 알 수 있었고, 열처리로 인해 결정화 되면서 전체 박막의 두께가 줄어들었으며, $MoSe_2$ 층의 배양성은 c축이 Mo 표면과 수직 방향으로 성장된 것을 알 수 있었다. Mo 박막의 두께가 1.2 ${\mu}m$와 0.6 ${\mu}m$인 AZO/i-ZnO/CdS/CIGS/Mo/SLG 구조로 이루어진 CIGS 박막 태양전지를 제조하였다. Mo 박막의 두께가 1.2 ${\mu}m$일 때 보다 0.6 ${\mu}m$일 때 CIGS 박막 태양전지의 변환 효율은 9.46%로 비교적 우수한 특성을 나타났다. CIGS 박막 태양전지에서 하부전극인 Mo 박막 특성은 유리기판 및 광흡수 층과의 계면 형성 따라 큰 영향을 미친다는 것을 알 수 있었고, 유리기판의 플라즈마 처리와 Mo 박막의 두께조절로 Na 효과 및 $MoSe_2$층 형성 제어함으로써 CIGS 박막 태양전지의 특성 개선에 효과를 가질 수 있었다.

토마토 뿌리조직에서 분리한 마이크로솜 이온펌프의 특성 (Characterization of Microsomal ATPases Prepared from Tomato Roots)

  • 조광현;사공정;김영기
    • Applied Biological Chemistry
    • /
    • 제41권2호
    • /
    • pp.130-136
    • /
    • 1998
  • 토마토의 뿌리조직에 존재하는 여러 가지 이온이동 기작을 밝혀내기 위하여 뿌리조직으로부터 마이크로솜을 분리하였고, 마이크로솜에 존재하는 이온점프(ATPase)의 활성을 측정하였다. 원형질막과 액포막에 위치하는 $H^+-ATPase$들의 활성은 각각의 선택적 저해제인 vanadate와 $NO^-_3$를 이용하여 평가하였고, 이들의 활성은 각각 마이크로솜 ATPase 총활성의 ${\sim}30%$, ${\sim}38%$로 나타났다. 이들 두 가지 저해제 효과는 additive하게 나타났으며, 전체활성의 약 $50{\sim}70%$를 저해함을 확인하였다. 마이크로솜 ATPase활성은 pH의 영향을 받으며, 최대 활성은 pH 7.4에서 나타났다. ATPase 활성은 또한 10 mM 이상의 $K^+$에 의해서 약 30% 증가를 보였으며, $K^+$에 의한 활성촉진 효과는 $Na^+$에 의해서 완전히 저해되었다. $K^+$에 의한 ATPase 활성증가 기작을 조사하기 위해, 반응용액의 $K^+$농도를 조절하면서 선택적 저해제들의 효과를 측정하였다. 반응용액에 $K^+$이 없는 조건과 120mM $K^+$을 함유하는 조건에서 vanadate는 ATPase 활성을 동일하게 27% 저해하였으나, $NO^-_3$는 각각의 조건에서 32%, 40% 저해하였다. 이것은 $NO^-_3$에 민감한 액포막의 $H^+-ATPase$활성이 $K^+$에 의해서 촉진된다는 것을 시사한다. 마이크로솜 ATPase 활성은 $Ca^{2+}$에 의해서도 저해되었으며, $NO^-_3$$Ca^{2+}$에 의한 저해효과를 억제하였다. 이상의 결과는 토마토 뿌리조직의 마이크로솜 ATPase중 액포막의 $H^+-ATPase$ 활성이 $K^+$에 의해서 증가하며, $Ca^{2+}$에 의해서 저해되는 것을 보여준다.

  • PDF