• Title/Summary/Keyword: plasma column

Search Result 236, Processing Time 0.033 seconds

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

Chromatographic Analysis of Cilostazol in Human Plasma

  • Park, Young-Joon;Park, Kyung-Mi;Ban, Eun-Mi;Chun, Soo-Kyung;Kim, Yang-Bae;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.402.3-403
    • /
    • 2002
  • Cilostazol. a quinolinone derivative that inhibits phosphodiesterase. is used for the treatment of intermittent claudication resulting from peripheral arterial disease. In order to perform pharmacological and pharmacokinetic studies of cilostazol, specific. sensitive and reproducible analysis methods are demanded. Therefore. in the present study. an analytical method of cilostazol in human plasma was developed using semi-microbore HPLC equipped with automated column switching system. (omitted)

  • PDF

High Performance Liquid Chromatographic Assay of Non-steroidal Anti-inframmatory Drugs in Plasma (혈장중 비스테로이드성 소염진통제의 HPLC분석)

  • Baek Chai-Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.5 no.2
    • /
    • pp.71-74
    • /
    • 1995
  • A high performance liquid chromatographic method has been developed for the simultaneous analysis of non-steroidal anti-inflammatory drugs in plasma. The simultaneous determination of ibuprofen, fenoprofen and ketoprofen is performed by RP-HPLC with UV detection. The chromatographic system consisted of Spherisorb octyl column$(5{\mu}m)$ ; the mobile phase was $acetonitrile\;-\;0.5\%$ phosphoric acid(55 : 45, v/v) and the detection wavelength was 230nm. Tolmetin was employed as an internal standard. The method described is rapid and simple with sensitivity limits of $2.0{\mu}g/ml$ ibuprofen, $0.5{\mu}g/ml$ fenoprofen and $0.3{\mu}g/ml$ ketoprofen and is suitable for routine clinical and pharmacokinetic studies.

  • PDF

Studies on the anti-coagulant component of Loranthus yadoriki

  • Lee, Sun-Kyung;Song, Hee-Sun;Yoo, Eun-A;Yang, Hyun-Ok
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.71-71
    • /
    • 2003
  • Methanol extract of Loranthus yadoriki showed the prolongation effect of bleeding time in vivo using mice in dose dependent manner. From the MeOH extract of Loranthus yadoriki, compound-A was isolated by the activity guided isolation method using silicagel column chromatography. The anti-coagulant activity was evaluated by the bleeding time test in vivo and plasma recalcification time test in vitro. Compound A showed moderate anti -coagulant activity on plasma recalcification time in vitro.

  • PDF

Effect of Oriental Onion (allium fistulosum) on Platelet Aggregation (파(Allium fistulosum)에 의한 혈소판 응집 억제작용)

  • 정진호;서동철;정승민;이주영;김영식
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.4
    • /
    • pp.273-276
    • /
    • 1996
  • Platelets serve many biological functions, including a major role in the haemostatic process. But platelets also play a crucial role in the formation of arterial thrombosis, arteriosclerosis and other pathologic processes. Thus, there have been many studies to develop new antiplatelet agents from foods and plants for decades. Inthis study, inhibitory effects of the oriental onion (Allium fistulosum) on platelet aggregation were investigated using platelet rich plasma (PRP). Water extracts of oriental onion was separated into two fractions (Fraction I and Fraction II) by Sephadex G-150 column. Platelet aggregations were inhibited by total water extracts as well as Fraction I and II. IC50 value of Fraction I was much lower than that of Fraction II. Inhibitory effects of total water extracts of oriental onion on ATP release by PRP were also observed.

  • PDF

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

Quantitative determination of pseudoephedrine in human plasma by reversed-phase liquid chromatography-electrospray ionization mass spectrometry

  • Kim, Jin-Ki;Cho, Jung-Hye;Woo, Jong-Soo;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.394.2-394.2
    • /
    • 2002
  • A sensitive and selective reversed-phase LC-ESI-MS method to quantitate pseudoephedrine in human plasma was developed and validated. Phenacetin was used as an internal standard. Samples were prepared simply by acetonitrile precipitation without an evaporation step. Chromatographic separation was achieved on a XTerra MS C18 column ($150{times}2.1$ mm I.D.. 3.5 $\mu\textrm{m}$ particles). using gradient elution with 0.5% (v/v) trifluoroacetic acid (TFA) in water and 0.5% (v/v) TFA in methanol at a flow-rate of 0.1 ml/min. (omitted)

  • PDF

Simultaneous determination of sildenafil and its active metabolite in human plasma using LC/MS/MS

  • Ji, Hye-Young;Kim, Sook-Jin;Lee, Hong-Il;Lee, Seung-Seok;Lee, Hye-Sook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.402.1-402.1
    • /
    • 2002
  • The LC/MS/MS method for the simultaneous determination of sildenafil and its active metabolite N-demethylsildenafil in human plama was developed. Sildenafil. its active metabolite and the internal standard. DA-8159 were extracted form human plasma by liquid-liquid partitioning. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45. v/v) as mobile phase. (omitted)

  • PDF

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of ε-Acetamidocaproic Acid in Rat Plasma

  • Kim, Tae Hyun;Choi, Yong Seok;Choi, Young Hee;Kim, Yoon Gyoon
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.203-209
    • /
    • 2013
  • A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ${\varepsilon}$-acetamidocaproic acid (AACA), the primary metabolite of zinc acexamate (ZAC), in rat plasma by using normetanephrine as an internal standard. Sample preparation involved protein precipitation using methanol. Separation was achieved on a Gemini-NX $C_{18}$ column ($150mm{\times}2.0mm$, i.d., 3 ${\mu}m$ particle size) using a mixture of 0.1% formic acid-water : acetonitrile (80 : 20, v/v) as the mobile phase at a flow rate of 200 ${\mu}l/min$. Quantification was performed on a triple quadrupole mass spectrometer employing electrospray ionization and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of AACA were linear over the concentration range of 20~5000 ng/ml in rat plasma. The coefficient of variation and relative error at four QC levels were ranged from 1.0% to 5.8% and from -8.4% to 6.6%, respectively. The present method was successfully applied for estimating the pharmacokinetic parameters of AACA following intravenous or oral administration of ZAC to rats.