• 제목/요약/키워드: plasma application

검색결과 908건 처리시간 0.028초

4-Tert-Octylphenol의 랫드에서의 조직분포 및 독성동태에 관한 연구 (Tissue Distribution and Toxicokinetics of 4-Tert-Octylphenol in Rats)

  • 강미경;안미령;정혜주;최선옥;최홍석;양지선;이용복;유태무;손수정
    • Toxicological Research
    • /
    • 제20권3호
    • /
    • pp.195-203
    • /
    • 2004
  • 4-Tert-Octylphenol (OP) is a surfactant additive widely used in the manufacture of a variety of detergents and plastic products. OP can disrupt endocrine function in humans and animals. This study was carried out to obtain toxicokinetic parameters of OP in male Sprague-Dawley (SD) rats. Male rats were administered with OP by single oral application of 200 mg/kg body weight. Blood, urine and tissues samples were taken at several time intervals after administration. Analysis of samples for OP was performed by column-switching high performance liquid chromatography (HPLC). In addition, we exam-ined tissue distribution and accumulation of OP after single oral application of 50, 100, and 200 mg/kg, single intravenous injection of 1, 5 and 10 mg/kg or daily application of 50 mg/kg for 14 consecutive days. After single oral administration of 200 mg/kg, Cmax of 213 $\pm$ 123 ng/ml was reached within the first 1.3 hr (Tmax) in the plasma. AUC was calculated for 1,333$\pm$484 ngㆍhr/ml. The final elimination half-life of plasma was longer than that of urine, but urinary clearance was lower than oral. A very small fraction of OP (Fe < 0.0017%) was excreted in urine within 24 hr. These results indicated that the major excretion route of OP was not urine. The mean maximal tissue distribution of OP was obserbed at 6 hr after treatment and slowly decreased time-dependently. High OP concentrations were detected in fat at 24 hr. The OP in fat was slowly released with longer elimination half-life and lower clearance than that of other tissues. OP was not accumulated in the liver following single oral application but 14-day oral treatments resulted in two-fold accumulation. It was probably due to the saturation of detoxification pathways. On the other hand, the mRNA expression of cytochrome P450 isoforms except CYP2C11 was not affected by OP at any dose. The expression of CYP2C11 mRNA decreased in a dose-dependent manner. This result suggests that OP changes expression of the male-specific cytochrome P450 isoforms in rat liver, and these changes are closely related to the toxic and estrogenic effect of OP.

AC-PDP의 휘도와 효율 향상을 위한 Dichroic Mirror의 응용에 관한 연구 (A study on the application of dichroic mirror for the improvement of luminance and luminous efficacy in an AC Plasma Display Panel)

  • 송병무;김중균;황만수;황기웅
    • 한국진공학회지
    • /
    • 제10권1호
    • /
    • pp.98-103
    • /
    • 2001
  • 차세대 평판 디스플레이로서 플라즈마표시기(Plasma Display Pannel, PDP)는 현재 350 $\textrm{cd/cm}^2$의 휘도와 l lm/W 정도의 효율을 갖는 AC형 PDP가 개발되어 있으나, 음극선관(CRT)의 피크 휘도가 700 $\textrm{cd/cm}^2$, 효율이 수 1 m/W인 것을 감안하면 음극선관을 대체할 수 있는 표시기가 되기 위해서는 PDP의 휘도와 효율을 더욱 개선시킬 필요가 있다. 반사형 AC-PDP셀 내에서 가스 방전으로 발생된 진공 자외선(Vacuum Utraviolet, VUV) 중 배면판 쪽으로 진행되는 부분은 형광체를 여기시켜 가시광을 발생시키게 되지만, 전면판 쪽으로 진행되는 부분은 발광에 사용되지 못하고 있다. 본 연구에서는 PDP 셀 전면판의 유전체와 보호막 사이에 VUV를 반사시킬 수 있는 다이크로익 미러(Dichroic mirror)를 증착함으로써 셀 내의 VUV 이용 효율을 증가시켜 휘도와 효율을 향상시킬 수 있는 방법을 제안하였다. 다이크로익 미러를 정확하게 설계하기 위해서 미러에 사용되는 $MgF_2$, $LaF_3$, MgO 박막의 VUV 영역에서의 광학 계수(Optical Constant)를 실험과 시뮬레이션을 이용한 광도 측정법(Photometric method)을 통해서 구하였다 (1). 이 값들을 이용해서 플라즈마 표시기의 패널 방전에서 방출되는 빛의 휘도를 결정짓는 가장 중요한 요소인 147nm 부근의 진공자외선을 반사시킬 수 있는 다이크로익 미러를 설계하였다. 다이크로익 미러는 전자빔 증착기 (I-beam evaporator)를 이용하여 증착되었고, 박막의 광학 계수 결정을 위한 반사도(Reflectance), 투과도(Transmittance) 측정과 다이크로익 미러의 반사도 측정은 Reflectometer를 이용해 측정하였다. 패널 실험은 동일한 패널 내에 반쪽 면에만 다이크로익 미러를 증착시켜 방전 전압에 따른 휘도와 효율을 미러가 없는 면과 동일 조건하에 비교 측정하였다. 여러 방전 조건하에서 다이크로익 미러를 AC-PDP에 적용한 경우가 그렇지 않은 경우보다 휘도와 효율이 약 20-30% 정도 증가함을 확인하였다.

  • PDF

악골결손부에 PRP적용후 획득된 골의 변화량 (AUGMENTED BONY CHANGE FOLLOWING PLATELET RICH PLASMA(PRP) APPLICATION ON MAXILLARY DEFECT)

  • 김욱규;김용덕;변준호;신상훈;정인교
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권4호
    • /
    • pp.219-225
    • /
    • 2003
  • Purpose: Platelet Rich Plasma(PRP) application is increasing with sinus inlay bone graft, but there is few research with radiographic ananlysis on effect of PRP in maxillary sinus. The author investigated the amount of bony changes of maxillary sinus for dental implantation among the patients with maxillary inlay graft. Materials and Methods: With 10 patients who were treated with sinus inlay autologous bone grafting combined with PRP technique, and with 5 patients who were treated with sinus inlay grafting only without PRP, the panoramic radiographys which were taken at preoperation, immediate postoperation, 3months postoperation, and 4 months postoperation(a month after dental implantation)periods were analysed. The films had been scanned, and then proceeded throughout image analysis system. The bone density of maxillary grafted sites was compared with adjacent tooth enamel density and remeasured according to density luminosity of each film. The density changes on PRP group and bone graft only group were analysed with non-parameteric statistics method. Results: In PRP combined patients group, bone density on postoperation periods was increased totally. The remarkable enhanced change of bone density was observed on 3 months postoperation period, thereafter the increasing rate was slightly reduced. In only bone graft patients group, bone density on postoperation periods was also increased compared with preoperation period, but the bone density of 4 months postoperation period was decreased compared with 3 months postoperation period. The amount of bone density on PRP group was significantly changed according to periods in contrast to bone graft only group. Conclusion: The bone density on PRP group was remarkably increased at 3 months postoperation compared to bone graft only group and it was seemed to be associated with more new bone formation, less grafted bone resorption at bone grafted sites with PRP.

탈지 겨자씨 소재 가식성 필름의 물리적 특성 향상을 위한 콜드 플라즈마의 적용 (Application of cold plasma treatment as a method to improve the physical properties of defatted mustard meal-based edible films)

  • 정하은;오윤아;민세철
    • 한국식품과학회지
    • /
    • 제53권5호
    • /
    • pp.634-639
    • /
    • 2021
  • 질소, 산소, 헬륨, 아르곤, 그리고 공기 가스로 DMM 필름을 CP 처리했을 때 산소와 공기를 이용한 처리는 필름의 신장률에 변화를 주지 않으면서 인장 강도와 모듈러스를 감소시켰고, 헬륨과 아르곤 가스를 이용한 CP 처리는 인장 강도와 신장률에 변화를 주지 않으면서 모듈러스를 감소시켰기 때문에 산소, 공기, 헬륨, 그리고 아르곤 가스를 이용한 CP 처리를 통해 필름의 인장 특성을 개선시킬 수 있음을 확인할 수 있었다. 사용한 가스와 상관없이 CP 처리는 필름의 색, 수증기 투과도, 그리고 표면 형태에 영향을 주지 않았으나, 헬륨-CP와 아르곤-CP 처리는 필름의 인쇄 적성을 증가시켰다. DMM 필름에 대한 아르곤-CP의 처리 전력 및 처리 시간은 필름의 황색도에는 유의한 영향을 주었으나(p<0.05), 처리 전력과 시간의 변화에 따른 경향은 확인할 수 없었다. 전체적으로 본 연구의 결과는 아르곤-CP 처리가 DMM 필름의 물리적 특성을 향상시키는 기술로 발전할 수 있음을 보여주었고, 이를 통해 DMM 뿐만 아니라 이와 유사한 농산물 가공 부산물을 소재로 제작된 필름의 특성을 개선하는 기술로 CP 처리가 개발될 수 있음을 확인할 수 있었다.

$[^{51}Cr]Cr(III)$-EDTA 착물 합성 및 $[^{51}Cr]Cr(III)$-EDTA 주사후 두경부 방사능 계측에 의한 사구체 여과율 측정 (Synthesis of $[^{51}Cr]Cr(III)$-EDTA Complex and Measurement of Glomerular Filtration Rate br Radioactivity Counting of Head and Neck Region)

  • 양승대;임상무;전권수;서용섭;윤용기;박현;우광선;정위섭;오옥두;이종두
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.364-370
    • /
    • 1994
  • 원자력병원에 설치된 MC-50 싸이클로트론에서 생산된 무담체 $^{51}Cr$-EDTA의 합성법 및 정상 성인 남자자원자를 대상으로 무담체 $^{51}Cr$-EDTA 주사후 사구체여과율을 측정하고, 이 검사 중 피검자가 받는 방사능 흡수선량을 MIRD system의 계산법으로 계산하여 다음과 같은 결과를 얻었다. 1) $^{51}Cr$-EDTA는 bicarbonate 촉매하에 합성하였으며 이 방법은 기존의 방법보다 짧은 시간내에, 상온에서 반응이 완결되는 장점이 있으며 이 연구를 통하여 국내에서도 비방사능이 월등히 높은 무담체 $^{51}Cr$-EDTA의 사용이 가능하게 되었다. 2) GFR 측정시 $^{51}Cr$-EDTA 주사후 두경부 방사능 계측으로 혈액채취를 대신 할 수 있고, 경험적 공식이 아닌 2-compartment model에 의한 계산법을 이용할 수 있어 간편하게 임상이용이 가능하며 한국인의 체형에 맞는 새로운 공식의 유도가 가능할 것으로 기대된다. 3) $50{\mu}Ci$ $^{51}Cr$-EDTA의 전신방사능 흡수선량은 무시할 수 있는 정도임을 알 수 있었으며, MIRD system은 아주 적은 방사능 오염의 피폭 선량측정에 유용함을 알 수 있었다.

  • PDF

Al2O3 High Dense Single Layer Gas Barrier by Neutral Beam Assisted Sputtering (NBAS) Process

  • 장윤성;홍문표
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.157-157
    • /
    • 2015
  • Recently, the growing interest in organic microelectronic devices including OLEDs has led to an increasing amount of research into their many potential applications in the area of flexible electronic devices based on plastic substrates. However, these organic devices require a gas barrier coating to prevent the permeation of water and oxygen because organic materials are highly susceptible to water and oxygen. In particular, high efficiency OLEDs require an extremely low water vapor transition rate (WVTR) of $1{\times}10^{-6}g/m^2day$. The Key factor in high quality inorganic gas barrier formation for achieving the very low WVTR required ($1{\times}10^{-6}g/m^2day$) is the suppression of defect sites and gas diffusion pathways between grain boundaries. In this study NBAS process was introduced to deposit enhanced film density single gas barrier layer with a low WVTR. Fig. 1. shows a schematic illustration of the NBAS apparatus. The NBAS process was used for the $Al_2O_3$ nano-crystal structure films deposition, as shown in Fig. 1. The NBAS system is based on the conventional RF magnetron sputtering and it has the electron cyclotron resonance (ECR) plasma source and metal reflector. $Ar^+$ ion in the ECR plasma can be accelerated into the plasma sheath between the plasma and metal reflector, which are then neutralized mainly by Auger neutralization. The neutral beam energy is controlled by the metal reflector bias. The controllable neutral beam energy can continuously change crystalline structures from an amorphous phase to nanocrystal phase of various grain sizes. The $Al_2O_3$ films can be high film density by controllable Auger neutral beam energy. we developed $Al_2O_3$ high dense barrier layer using NBAS process. We can verified that NBAS process effect can lead to formation of high density nano-crystal structure barrier layer. As a result, Fig. 2. shows that the NBAS processed $Al_2O_3$ high dense barrier layer shows excellent WVTR property as a under $2{\times}10^{-5}g/m^2day$ in the single barrier layer of 100nm thickness. Therefore, the NBAS processed $Al_2O_3$ high dense barrier layer is very suitable in the high efficiency OLED application.

  • PDF

Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica® Capsule (Pregabalin 150 mg)

  • Jang, Ki-Ho;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • 제41권4호
    • /
    • pp.255-262
    • /
    • 2011
  • Method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of pregabalin in plasma samples. Acquisition was performed by monitoring the transitions: m/z 160.1${\rightarrow}$142.2 for pregabalin and m/z 423.2${\rightarrow}$207.1 for losartan (as an internal standard). After cold acetonitrileinduced protein precipitation of the plasma samples, separation was performed with C18 column by isocratic mobile phase consisted of 10 mM ammonium acetate and acetonitrile (15:85, v/v). Results were linear over the concentration ranged from 0.1 to $10{\mu}g$/mL and the correlation coefficients (r) were $\geq0.99$. Intra- and inter-day precisions were $\leq6.02$ and $\leq11.04%$, respectively, and intra- and inter-day accuracies were 96.60-101.09 and 98.10-102.60%, respectively. This validated method was successfully applied to a bioequivalence study of two formulations of pregabalin, Daewoong pregabalin capsule (Daewoong Pharm. Co., Ltd.) and Lyrica$^{(R)}$ capsule (Pfizer Korea Ltd.) in twenty eight healthy Korean volunteers. The subjects received a single oral dose of each formulation (150 mg as pregabalin) in a randomized $2{\times}2$ crossover study and plasma samples were obtained from each subject at predetermined time intervals. Then, the pharmacokinetic parameters ($AUC_{0-t}$, $C_{max}$ and $T_{max}$) were calculated and statistically analyzed to assess the differences between two formulations. The 90% confidence intervals for the log-transformed data were acceptable range of log 0.8-log 1.25 (e.g., log 1.0048-log 1.0692 for AUC0-t, log 0.9142-log 1.0421 for $C_{max}$). Thus, $AUC_{0-t}$ and $C_{max}$ met the criteria of the Korea Food and Drug Administration (KFDA) for bioequivalence test indicating that Daewoong pregabalin capsule was bioequivalent to Lyrica$^{(R)}$ capsule.

유기박막트랜지스터 응용을 위해 플라즈마 중합된 Styrene 게이트 절연박막 (Plasma Polymerized Styrene for Gate Insulator Application to Pentacene-capacitor)

  • 황명환;손영도;우인성;바산바트호약;임재성;신백균
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.327-332
    • /
    • 2011
  • ITO가 코팅된 유리 기판 위에 플라즈마 중합법으로 styrene 고분자 박막을 제작하고 상부 전극을 진공 열증착법으로 제작된 Au 박막으로 한 MIM (metal-insulator-metal) 소자를 제작하였다. 또한, 플라즈마 중합된 styrene 고분자 박막을 유기 절연박막으로 하고 진공열증착법으로 pentacene 유기반도체 박막을 제작하여 유기 MIS (metal-insulator-semiconductor) 소자를 제작하였다. 플라즈마 중합법으로 제작된 styrene (ppS; plasma polymerized styrene) 고분자 박막은 styrene 단량체(모노머) 고유의 특성을 유지하면서 고분자 박막을 형성함을 확인하였으며, 통상적인 중합법으로 제작된 고분자 박막 대비 k=3.7의 높은 유전상수 값을 보였다. MIM 및 MIS 소자의 I-V 및 C-V 측정을 통하여 ppS 고분자 박막은 전계강도 $1MVcm^{-1}$에서 전류밀도 $1{\times}10^{-8}Acm^{-2}$ 수준의 낮은 누설전류를 보이고 히스테리시스가 거의 없는 우수한 절연체 박막임이 판명되었다. 결과적으로 유기박막 트랜지스터 및 유기 메모리 등 플렉서블 유기전자소자용 절연체 박막으로의 응용이 기대된다.

Pin-to-plate Type 대기압 PECVD 방법을 이용해 성장된 다중벽 탄소나노튜브의 전계방출 특성연구 (Field Emission Properties of Multiwalled Carbon Nanotubes Synthesized by Pin-to-Plate Type Atmospheric Pressure Plasma Enhanced Chemical Vapor Deposition)

  • 박재범;경세진;염근영
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.374-379
    • /
    • 2006
  • 본 연구에서는 전계 방출소자로 사용하기 위한 탄소나노튜브의 합성 방법으로, pin to plate type의 대기압 플라즈마 소스를 사용한 AP-PECVD(Atmosphere pressure plasma enhanced chemical vapor deposition)를 이용하였으며, 이를 통하여 대기압에서 성장된 탄소나노튜브의 구조적 및 전기적 특성을 연구하였다. 유리 / 크롬 / 니켈을 기판으로 사용하여 $400{\sim}500^{\circ}C$ 변화 영역에서 탄소나노튜브를 성장시킨 결과 다중벽 탄소나노튜브가 얻어짐을 알 수 있었다. $500^{\circ}C$에서 성장시킨 탄소나노튜브의 경우 FT-Raman을 이용한 분석 결과 $I_D / I_G$ ratio 가 0.772 임을 관찰하였으며 TEM으로 분석결과, 내부의 그래파이트층은 15 - 20 층, 내부 직경은 10-15nm, 외부 직경은 30 - 40nm 이고, 각 층간의 간격은 0.3nm 임을 알 수 있었다. 또한 전계 방출 문턱전압은 $2.92V/{\mu}m$ 이고, FED 에서 요구되는 $1mA/cm^2$의 방출전류밀도는 $5.325V /{\mu}m$의 문턱전압 값을 가지는 것을 관찰하였다.

수중 유전체장벽방전 플라즈마를 이용한 아조 염색폐수 색도제거 (Decolorization of Azo Dyeing Wastewater Using Underwater Dielectric Barrier Discharge Plasma)

  • 조진오;이상백;목영선
    • 공업화학
    • /
    • 제24권5호
    • /
    • pp.544-550
    • /
    • 2013
  • 본 연구에서는 소수성 다공질 세라믹관이 결합된 수중 유전체장벽방전 플라즈마 반응기를 이용하여 모사 염색폐수의 색도저감을 조사하였다. 플라즈마에 의해 생성되는 활성성분들은 수명이 매우 짧으므로 생성되는 즉시 물과 접촉시켜야 효과적인 폐수처리가 가능하며, 또한 반응속도를 증가시키기 위해서는 기/액 접촉면적이 커야 하는데, 본 연구의 반응기는 두 가지 목적을 동시에 이룰 수 있다. 아조 염료로는 amaranth, 그리고 플라즈마 생성을 위한 기체로는 공기가 사용되었으며, 방전전력, 기체 유량, 용존 음이온, 염료 초기농도 등 색도 제거에 미치는 다양한 변수의 영향이 평가되었다. 기체유량이 $1.5Lmin^{-1}$일 때, 플라즈마 기체가 염색폐수와 가장 효과적으로 접촉하였으며, 색도 제거가 가장 빠르게 일어났다. 염료 초기농도 $40.2{\mu}molL^{-1}$ (폐수부피 : 0.8 L), 방전전력 3.37 W의 조건에서 색도를 99% 이상 제거하는데 약 25 min이 소요되었다. 그밖에 염료의 초기농도가 낮을수록, 방전전력이 높을수록 색도 제거 속도가 증가하는 것으로 나타났다. 염소이온이 존재할 경우 색도 제거 속도가 빨라졌으나, 질산이온은 색도 제거 속도에 영향을 주지 않았다.