Synthesis of $[^{51}Cr]Cr(III)$-EDTA Complex and Measurement of Glomerular Filtration Rate br Radioactivity Counting of Head and Neck Region

$[^{51}Cr]Cr(III)$-EDTA 착물 합성 및 $[^{51}Cr]Cr(III)$-EDTA 주사후 두경부 방사능 계측에 의한 사구체 여과율 측정

  • Yang, Seung-Dae (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Lim, Sang-Moo (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Chun, Kwon-Soo (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Suh, Yong-Sup (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Yoon, Yong-Ki (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Park, Hyun (Department of Cyclotron Application Lab., Korea Caner Center HospitalWoo) ;
  • Woo, Kwang-Sun (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Chung, Wi-Sup (Department of Cyclotron Application Lab., Korea Caner Center Hospital) ;
  • Oh, Ok-Doo (Department of Yon Sei University) ;
  • Lee, Jung-Doo (Department of Cyclotron Application Lab., Korea Caner Center Hospital)
  • 양승대 (원자력병원 싸이클로트론 응용연구실) ;
  • 임상무 (원자력병원 싸이클로트론 응용연구실) ;
  • 전권수 (원자력병원 싸이클로트론 응용연구실) ;
  • 서용섭 (원자력병원 싸이클로트론 응용연구실) ;
  • 윤용기 (원자력병원 싸이클로트론 응용연구실) ;
  • 박현 (원자력병원 싸이클로트론 응용연구실) ;
  • 우광선 (원자력병원 싸이클로트론 응용연구실) ;
  • 정위섭 (원자력병원 싸이클로트론 응용연구실) ;
  • 오옥두 (연세대학교 보건과학대학) ;
  • 이종두 (원자력병원 싸이클로트론 응용연구실)
  • Published : 1994.11.30

Abstract

The purpose of this study is to evaluate the clinical application of the no carrier added $[^{51}Cr]Cr(III)$-EDTA complexes, produced at Korea Cancer Center Hospital. The $[^{51}Cr]Cr(III)$-EDTA complexes, usefut for measurement of GFR were prepared at room temperature in the presence of bicarbonate catalysts. The radiochemical purity of $[^{51}Cr]Cr(III)$-EDTA was over 99% by paper electrophoresis. The time activity curves were obtained by counting the blood samples from 5 volunteers and counting the head and neck regions with whole body counter after injection of the $^{51}Cr$-EDTA, respectively. After the nonlinear regression, the area under curve was obtained. The plasma clearance of the $^{51}Cr$-EDTA was calculated with injected dose/AUC. The clearance rate calculated with the head and neck counting data was in good agreement with the result from the plasma sample radioactivity at 1-3 hrs after injection. From this result, the counting of head and neck region and the nonlinear regression by 2-compartment model could be applied for the measurement of the clearance rate. Using MIRD system, the absorbed radiation dose was calculated by residence $time{\times}S$. The absorbed whole body radiation dose was negligibly small.

원자력병원에 설치된 MC-50 싸이클로트론에서 생산된 무담체 $^{51}Cr$-EDTA의 합성법 및 정상 성인 남자자원자를 대상으로 무담체 $^{51}Cr$-EDTA 주사후 사구체여과율을 측정하고, 이 검사 중 피검자가 받는 방사능 흡수선량을 MIRD system의 계산법으로 계산하여 다음과 같은 결과를 얻었다. 1) $^{51}Cr$-EDTA는 bicarbonate 촉매하에 합성하였으며 이 방법은 기존의 방법보다 짧은 시간내에, 상온에서 반응이 완결되는 장점이 있으며 이 연구를 통하여 국내에서도 비방사능이 월등히 높은 무담체 $^{51}Cr$-EDTA의 사용이 가능하게 되었다. 2) GFR 측정시 $^{51}Cr$-EDTA 주사후 두경부 방사능 계측으로 혈액채취를 대신 할 수 있고, 경험적 공식이 아닌 2-compartment model에 의한 계산법을 이용할 수 있어 간편하게 임상이용이 가능하며 한국인의 체형에 맞는 새로운 공식의 유도가 가능할 것으로 기대된다. 3) $50{\mu}Ci$ $^{51}Cr$-EDTA의 전신방사능 흡수선량은 무시할 수 있는 정도임을 알 수 있었으며, MIRD system은 아주 적은 방사능 오염의 피폭 선량측정에 유용함을 알 수 있었다.

Keywords